Page number 4
SPECIFICATIONS FlowCon PICV actuators FlowCon SM.0.0.0.3 (standard) 1 FlowCon SM.0.0.0.4 (standard failsafe) 1 FlowCon SM.0.0.0.6 (BACnet failsafe) 1 Supply voltage: Type: Power consumption: Control signal: Resolution: Feedback: Control mode: Failsafe function: Manuel override: Position indicator: Operation time: Ambient temperature: Humidity rating: Housing material: Protection: CE conformity: Programming: Cable: Calibration: Valve-actuator coupling: Protocol: Interface: Device profile: Baud rates support: Services (BIBBS) supported: Participants: 22-26V AC, 50/60 Hz or 22-26V DC Electrical, Bi-directional synchronous motor SM.0.0.0.3: 2.0VA standby / 5.0VA operating / 12VA max. SM.0.0.0.4/6: 3.5VA standby / 5.0VA operating / 12VA max. 2-10V DC 1:800 (2-10V) 2-10V DC Linear flow SM.0.0.0.3: Fail in place SM.0.0.0.4/6: Optional open or close (set on actuator) Yes Yes, through the actuator FIT.3-5: 190 sec (from closed to fully open valve) FIT.6: 317 sec (from closed to fully open valve) -10°C to +50°C / +14°F to +122°F 5.95% rH, no condensation UL94 V0-rated plastic IP54 including upside-down mounting EN 60730, class II Programming of all settings on interface with buttons and display or via BACnet Fixed, 5 wires x 0.75 mm 2 / AWG18 halogen free, 1 meter / 3 ft Additional for BACnet versions: Fixed, 3 wires x 0.75 mm 2 /AWG18 halogen free, 1 meter / 3 ft Automatic at startup Easy snap coupling BACnet MS/TP EIA-485 / RS-485 BACnet Application Specific Controller (B-ASC) type server 9600, 19200, 38400 and 76800 DS-RP-B, DS-WP-B, DM-DDB-B, DM-DOB-B and DM-DCC-B Up to 32 recommended, max. 127 participants Note 1: FlowCon warranty is voided using other actuators than supplied or recommended by FlowCon International. Tech note · FlowCon FIT DN50-250 / 2”-10” · november 2024 · www.flowcon.com Page 4 of 15
Page number 5
SPECIFICATIONS FlowCon Intelligent Interface Supply voltage: Power consumption: Cable, 3 groups: • Group 1: • Group 2: • Group 3: Communication standard: Control signal: Output signal: Humidity rating: Protection: Housing material: CE conformity: Protocol: Interface: Device profile: Baud rates supported: Services (BIBBS) supported: Participants: Load: 24V AC/DC 4W fixed, 1 wire with quick-connector, 3 meter / 9 ft (T1) fixed, 1 wire with quick-connector, 1 meter / 3 ft (T2) fixed, 3 wires, 0.6 meter / 2 ft (analogue actuator communication) fixed, 2 wires 0.6 meter / 2 ft (power and ground) fixed, 3 wires 0.6 meter / 2 ft (BACnet BMS communication) fixed, 1 wire with quick-connector, 1 meter / 3 ft (P1) fixed, 1 wire with quick-connector, 1 meter / 3 ft (P2) fixed, 3 wires, 0.6 meter / 2 ft (BACnet actuator communication) RS485 2-10V DC 2-10V DC 5.95% rH, no condensation IP54 including upside-down mounting UL94 V0-rated plastic Yes BACnet MS/TP EIA-485 / RS-485 BACnet Application Specific Controller (B-ASC) type server 9600, 19200, 38400,57600, 76800 and 115200 DS-RP-B, DS-WP-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DS-RPM-B and DM-RD-B Up to 32 recommended, max. 127 participants 1/8 unit load Temperature sensors (T1 and T2) Supply voltage: Cable: Signal output: Media temperature: Working pressure: Housing material: Protection: Probe length: Probe diameter: CE conformity: Connection: NA No cable, but with quick-connector Resistive -20°C to +120°C / -4° to +248°F 40 bar / 580 psi 304 stainless steel IP65 DN50-80 / 2”-3”: 12.7 mm / 0,5 in DN80-250 / 3”-10”: 84.7 mm / 3.3 in use of sensor pocket is recommended 6 mm / 0.236 in Yes 1/4” ISO Performance data: • Sensor type: • Accuracy: • Linearity: • Long time stability: • Response time: PT1000 0.5% FS (Full Scale) ±0.5% FS (Full Scale) 0.1% FS (Full Scale) at 50°C (122°F): 2.3 sec / at 90°C (194°F): 5.4 sec. Tech note · FlowCon FIT DN50-250 / 2”-10” · november 2024 · www.flowcon.com Page 5 of 15