Multiple-Use Emergency Medical Garment Item Test Method Requirement Whole Garment Garment Composite Garment material Sigma 7.0 Overall ensemble function and integrity Liquid tight integrity overall function Evaporative resistance Total heat loss Biopenetration (test one) Tensile strength Burst strength Puncture propagation tear resistance Tear resistance Water absorption resistance ASTM F1154 (Sec. 8.40) No liquid penetration ASTM F1359 (Sec. 8.2) (Sec. 8.42) ASTM F1868 (Sec. 8.32) ASTM F1671 (Sec. 8.3) ASTM D5034 (Sec. 8.4) ASTM D3787 (Sec. 8.5) No liquid penetration after 8 min. ≤ 30 Pa m2 /W ≥ 450 W /m2 No penetration of Phi-X174 bacteriophage ≥ 225.5 N (50 lbf) ≥ 178 N (40 lbf) ASTM D2582 (Sec. 8.6) ≥ 25 N (5½ lbf) ASTM D5587 (Sec. 8.7) AATCC 42, mod. (Sec. 8.31) ≥ 36 N (8 lbf) ≤ 30% Flammability ASTM D1230 (Sec. 8.35) Flame spread ≥ 3.5 sec. Garment seams Sigma 7.0 Garment seams Crosstech® S/R Garment labels Garment Composite Sigma 7.0 / Crosstech® S/R Biopenetration (test one) ASTM F1671 (Sec. 8.3) Seam breaking strength Coat sleeve, Trouser inseam, 516 & 301/LSbm-4 Seam breaking strength Coat outseam, Trouser upper outseam, Crotch gusset, 301/LSc-2 Seam breaking strength Collar attachment, 301/LSq-3 (inside and out) Seam breaking strength Waistband attachment, 301/LSq-2 Seam breaking strength Pocket flap attachment, 301/LSd-1 Seam breaking strength Coat sleeve attachment seam, Trouser lower outseam, Coat and trouser panel attachment seam, Coat storm flap attachment, 505 & 301/LSq-3 ASTM D1683 (Sec. 8.8) No penetration of Phi-X174 bacteriophage ≥ 225.5 N (50 lbf) Seam breaking strength Liquid barrier structural, 301/SSa-1 ASTM D1683 (Sec. 8.8) ≥ 225.5 N (50 lbf) Label durability and legibility Abrasion Laundering Evaporative resistance Total heat loss (Blood-borne pathogen option) NFPA 1951-2020 (Sec. 8.33) (Sec. 8.42) ASTM F1868 (Sec. 8.32) In place and legible ≤ 30 Pa m2 /W ≥ 450 W /m2 NFPA 1999 Results (Avg.) Pass Pass 11 479.0 Pass 835.7 N 817 N Warp: 267 N Fill: 172 N 146 N 4% Warp/Wales: Did not ignite Fill/Courses: Did not ignite Pass 855.30 N 816.20 N 866.30 N 900.20 N 724.9 N 881.50 N 584.30 N Pass Pass 11 479.0

Multiple-Use Emergency Medical Garment Item Test Garment metal parts Corrosion resistance Method ASTM B117 (Sec. 8.22) Requirement No corrosion Breaking strength Garment fastener tape (Hook & Loop) Shear strength ASTM D5034 (Sec. 8.39) ≥ minimum breaking strength in Table 1 ofA-A-55126B ASTM D5169 (Sec. 8.39) ≥ minimum shear strength in Table 1 of A-A-55126B Peel strength Garment zippers Crosswise breaking strength ASTM D5170 (Sec. 8.39) ≥ minimum peel strength in Table 1 of A-A-55126B A-A-55634A Report NFPA 1999 Results (Avg.) Pass 16mm width: 126.0 (hook), 121.0 (loop) 25mm width: 203.0 (hook), 218.0 (loop) 75mm width: 341.0 (hook), 318.0 (loop) 100mm width: 333.0 (hook), 339.0 (loop) 16mm width: 6.3 psi 25mm width: 12.4 psi 75mm width: 12.9 psi 100mm width: 17.2 psi 16mm width: 1.0 lbs/in 25mm width: 1.0 lbs/in 75mm width: 1.1 lbs/in 100mm width: 1.3 lbs/in UL Recognized Component

    ...