TECHNICAL DATASHEET THE TFE TFN THA THT THP TFF TFM CHARACTERISTICS • Pilot hole in concrete needed, thread is created by the anchor during the Installation process. • Use for high loads. • Assessed for 2 installation depths and 3 for Ø10. • Use in cracked and non-cracked concrete. • Comply with guideline VdS CEA 4001:2021- 01(07) “Guidelines for sprinklers systems. Planning and installation” • Suitable when reduced edge distances or spacing required. • Qualified for static and cuasi-static. • Easy installation. • Installation through the fixture. • Reusable • Removable, leaving concrete surface flat. • Variety of lengths and sizes, assembly flexibility. • VdS available from Ø6 to Ø18 • Available in INDEXcal APPLICATION ASSESMENTS • Structural fixings in cracked and uncracked concrete subject to dry internal conditions. • Glazing, windows and storefronts • Racking and shelving • Attaching railings, handrails and ledgers • Fixings wood structures in concrete APPLICATION EXAMPLES TFS BASE MATERIAL SIZE RANGE Ø5 - Ø18 DRILL CONDITION DRY WET FLOODED MAXIMUMUM LOADS RECOMMENDED FOR CRACKED AND UNCRACKED CONCRETE [kg] TH 2830 494 1310 1822 2107 2107 673 857 Ø5 Ø6 Ø8 Ø10 Ø12 Ø14 Ø16 Ø18 Ref. FT THE-en Rev: 8 01/06/23 1 of 21