To download individual pages from this catalog*:
- Click the print icon above
- Select Adobe PDF as your printer
- Enter the desired page number or range
*You may also visit the product web page and click the print icon in the upper right corner.
To download individual pages from this catalog*:
*You may also visit the product web page and click the print icon in the upper right corner.
1.6 Rev. 10-15 Shaded area indicates change M-94 KITS AND ACCESSORIES Safety Flange Repair Kit Safety Flange Repair Kit consists of (4000001719): Used for both 4-1/2" and 5-1/4" • (2) Frangilble standpipe coupling • (2) Frangible standpipe bolts &nuts •(1)UpperstandpipeO-ring • (1) Frangible rod Coupling • (2) Rod Coupling pins •(1)DampenerO-ring Main Valve Kit Main Valve Kit consists of: 4-1/2" - 240629 5-1/4" - 240630 • (1) Valve Seat Ring •(2)DrainValveFacing •(2)SeatRingO-ring •(1)MainValve Extension Kit Extension Kit consists of (Order by length): Used for both 4-1/2" & 5-1/4" • (2) Clevis pins • (1) Rod • (2) Spring retainer rings • (1) Standpipe •(1)Instructionsheet • (1) Stainless steel extension rod •Extensionlengths:0'-6",1'-0", coupling 1'-6",2'-0",2'-6",3'-0",3'-6",4'-0" •(1)Extensionflange •(1)Bonnet/UpperstandpipeO-ring •(2)Boltsandnuts Gasket Kit Gasket Kit consists of (240628): •(1)OperatingNutSeal •(1)BonnetSeal •(1)RevolvingNutO-ring •(2)HoldDownNutO-ring •(1)InnerRevolvingNutO-ring • (1) Standpipe Coupling Seal •(1)Dampener • (1) Thrust washer Disassembly Tool Kit Disassembly Tool Kit consists of (4000001726): • (1) Seat removal wrench& handle • (1) Spanner wrench •(1)Allenwrench(1/8") •(1)Allenwrench(7/32") A-316 & A-317 A-316 Nozzle wrench: Integral Storz Pumper Connection and Storz adaptor: Usedtoquicklyconnectto hydrants.AvailableonSentinel 250™orM-94hydrant. Used to remove and install threaded in hose and pumpernozzles. Sizes:2-1/2",3",3-1/2",4", 4-1/2",and5" A-317 Nozzle lock installation tool: Usedtoinstallnozzle locking device. Integral Storz Wrench Used to remove the integral StorzPumperConnection. Sizes: 4"-287402& 5"-287403 Muelleralsooffers5"Storz adaptorsforconnectionto4-1/2" NSTnozzles.MuellerStorz adaptorsmeettherequirementsof NFPA1963andareratedfor250 psig operating pressure.
ORDERING INSTRUCTIONS 1.7 Shaded area indicates change Rev. 2-14 Ordering - Directions for Ordering. WhenorderingtheSentinel250 orMETROPOLITAN /M-94 DuctileIronhydrant,pleasespecifythefollowing: ™ ® Information Necessary When Ordering Spare Parts WhenorderingpartsfortheSentinel250or METROPOLITAN/M-94METROPOLITAN/M-94hydrant, pleaseprovidethefollowinginformation: 1.Sizeofmainvalveopening(4-1/2"or5-1/4").Thisiscast in raised letters on the back of the upper standpipe section number 25. 2.Openingdirectionclockwise(right)orcounterclockwise(left). 3.Sizeandshapeofoperatingnut(standardAWWApentagon is1-1/2"pointtoflat).Nozzlecapstakesamesizeandshape asspecifiedforoperatingnut. 4.Sizeandthreaddetailforhoseandpumpernozzleorcaps. IfotherthanNationalStandard,refertopreviousordersorsend drawingsandcompletethreaddetailorsendsamplenozzle. 5.Depthoftrench(alsocalleddepthofbury).Itisthedistance from the ground line to the bottom of the connecting pipe. Allsparepartsarepaintedblackexceptabovegroundline items,whichareprimecoatedforfinishpaintingbycustomer. 250 psig working pressure and 500 psig test pressure. Conforms to AWWA Standard C502, UL Listed & FM Approved. Two Way Three Way Two Hose Nozzles Sentinel 250 A-451 A-453 M-94 A-494 A-495 Two Hose Nozzles and One Pumper Nozzle Sentinel 250 A-451 A-453 M-94 A-494 A-495 1.Quantityrequired. 2.Sizeofmainvalveopening(4-1/2"or5-1/4"). 3.Openingdirection. 4.Operatingnutsizeandshape. 5.Numberandsizeofnozzles. 6.Nozzlethreaddetail(NSTorother). 7.Depthofbury-distancefromgroundlinetothebottomofthe hydrant inlet (same as depth of trench). 8.Typeandsizeofinletconnection. 9.Colorcode.Unlessotherwisespecifiedthehydrantwillbe paintedfireengineredfromthegroundlineup. Nominal Size of Main Valve Openings Two Pumper Nozzles Sentinel 250 M-94 A-494 A-495 4-1/2" 5-1/4" A-451 A-453 Hydrant bury lengths are as follows: 1'6", 2'0", 2'6", 3'0", 3'6", 4'0", 4'6", 5'0", 5'6", 6'0", 6'6", 7'0" Size of Hydrant 4-1/2" 5-1/4" Size and Types of Inlet Connections Flanged M-94 6" 6" Sentinel 250 4"and6" 4"and6" Mechanical Joint M-94 6" 6" Sentinel 250 4"and6" 4",6",and8" M-94 6" 6" D-150 Sentinel 250 4"and6" 4"and6" M-94 6" Slip-On® Sentinel 250 6" 6" Flanged Inlet Forflangedendpipeorwhenusedwith aflangedendauxiliarygatevalve.The flangeisfacedanddrilledtothe125lbs. AmericanStandard-ANSIB16.1.Option forISOdrillingavailable(PN10/16). Mechanical Joint Inlet ForuseonDuctileIron,C900PVC andCastIronpipewithenddimension compliantwithANSI/AWWAC11. Furnished with the connecting gland, plain rubber gasket, and bolts and nuts, unless otherwisespecified.Inlethastwostrapping lugs. Can also be furnished on order with set screws in the gland for bonding. D-150 Mechanical Joint Inlet This is an enlarged connection suitable for usewithclass150CastIronpipeorClass DPitCastpipebyusingoneoftwotype gasketsavailable.ForClass150CastIron pipeuseDuckTippedgasket.ForClass DPitCastpipeusePlainRubbergasket. Complete with gland, cast iron bolts and nuts,andgasketspecified.Thesegaskets and glands will not interchange with those ontheStandardizedMechanicalJoint. Can be furnished with set screws in the gland for electrical bonding upon order. Inlethastwostrappinglugs. Slip-On Joint Inlet TheSlip-onendsfitplainendofclasses 150, 200 and 250 cast iron; ductile iron and classes 150 and 200 cast iron O.D.PVC.Classes150,200and250 manufacturedtoANSIA21.6andANSI A21.8includingtheplainendofallmakes of cast iron pipe of the slip connection type.Inlethastwostrappinglugs.The regularSlip-Ongasketmaybeordered.