Page number 42

9.42 Rev. 9-17 Shaded area indicates changes D-5 ™ /DH-5 ™ Machine H-17490 Control Valve Bushing Installation Test Cap Completion Plug Wrench Drilling MAOP* Power Operator Machine Adapter Machine Adapter Bushing Shell Cutter Adapter Boring Bar Adapter Shell Cutter Pilot Drill Drill Drill Holder Cutting Grease Honing Stone Inserting MAOP* Machine Adapter Machine Adapter Bushing Boring Bar Adapter 1-PC Inserting Tool Extracting MAOP* Machine Adapter Extracting Tool 2" H-10914 2" - 36811 581264 125 psig H-604 36188 - - - - - 33537 1-1/2" 33316 88366 682560 125 psig 36188 - - 36190 125 psig 36188 88384 *Maximum Allowable Operating Pressure MUELLER ® NO-BLO ® SAVE-A-VALVE H-17490 2" H-10917 2" - 2" H-10918 2" - 3" H-10914 3" - 3" H-10917 3" - 36811 581264 36811 581264 36813 581264 36813 581264 250 psig H-604 36188 - - - - - 33537 1-1/2" 33316 88366 682560 250 psig 36188 - - 36190 250 psig H-604 36188 - - - - - 33537 1-1/2" 33316 88366 682560 125 psig H-604 36376 - 88601 - 36374 2-5/8" 36336 - - 88366 682560 250 psig H-604 36376 - 88601 - 36374 2-5/8" 36336 - - 88366 682560 250 psig 36188 - - 36190 125 psig 36376 - - 36190 250 psig 36376 - - 36190 250 psig 36188 88384 250 psig 36188 88384 125 psig 36376 88384 250 psig 36376 88384

Page number 43

MUELLER ® NO-BLO ® SAVE-A-VALVE DRILLING NIPPLE WELDING TYPE - 1440 PSIG o Catalog number – H-17491 o Sizes* – 3/4" x 2", 3/4" x 3", 1" x 3", 1-1/4" x 3", 2" x 3", 3" x 3", 3" x 6" o For use on steel pipe only o Nipple body is forged steel (ASTM A105) o Completion Plug makes primary seal o Steel Completion Cap makes secondary seal o 1440 psig** (9930 kPa) 9.43 Shaded area indicates change Rev. 6-10 H-17491 How to select equipment 1) Find chart on following pages containing desired combination of fitting and installation machine (shown in bold type at top of each page and chart). Note: for a given fitting there may be more than one machine and chart. 2) Under inlet size of fitting to be installed, select catalog number for type of control valve to be used. Options may include one or more of the following: H-10914 Bronze Gate Valve, H-17025 Control Chamber, H-10917 Slide Gate Valve, H-10918 Steel Ball Valve. 3) Under selected control valve, column lists equipment necessary for each operation on chosen size of fitting. Note: MAOP (Maximum Allowed Operating Pressure) provided for each operation must not be exceeded. MAOP may be different for each operation. Replacement Parts Replacement Parts Completion Cap Completion Plug 3/4" x 2" 502669 503125 3/4" x 3" 502669 503125 1" x 3" 52412 78898 Size* of Nipple 1-1/4" x 3" 52413 34060 2" x 3" 52430 36356 3" x 3" 52374 36402 3" x 6" 52374 36402 *First size is size of inlet, second is length of nipple. ** This is the maximum pressure of the fitting installed in the line at 100F for Class Locations 1, 2, 3 and 4 as defined in D.O.T./CFR TITLE 49 PART 192. It may be necessary to reduce the line pressure during the drilling, stopping or plugging operations to the maximum working pressure of the machine or its attachments. Refer to charts on following pages.

    ...