Page number 1

MUELLER ® By-Pass Meter Bar - FEATURES Rev. 12-06 Shaded area indicates changes 15.1 The Mueller® By-Pass Meter Bar allows you to easily replace an old meter while continuing gas flow to a residence or business. The innovative design bridges the gap between service piping and in-house piping to provide a stable support structure for gas meters while redirecting the gas flow through a by-pass mechanism using a single actuation operation from the center of the meter bar. This design allows for simple operating procedures — saving cost, time, and other valuable resources. The By-Pass Meter Bar is designed for use on natural gas services delivering up to 5 psi (34 kPa) delivery pressure. Mueller By-Pass Meter Bar Features ❏ Settings – ON, OFF, and BP (By-Pass) settings labeled on the meter bar. BP setting allows the user to by-pass the meter without interrupting flow to the customer. ❏ Constrained Motion Tab – Eliminates ability for 360° rotation to avoid possible user error. ❏ NPT Ports –Two bosses on the inlet and outlet of the meter bar tapped with ¼˝ NPT thread. Allows for confirmation that there is no substantial pressure drop downstream that would interrupt service to the customer. ❏ MAXIMUM WORKING PRESSURE – rated at 5 psi (34 kPa) ❏ Brackets – Match up with existing mounting kits to secure the meter bar to a residence ❏ Wrench Flat – 1.5" wide. ❏ Locking Hole – Compatible with a standard barrel lock and prevents tampering with the meter bar

    ...