9. Power sharing support. a) Defrost interval saved at power cycling. b) Faster startup ramp as per new SH regulator. 10.Air exchange (75m3/h) and pressure transmitters (NSK) are set as default when the controller is replaced. 11.When a temperature sensor is malfunctioning, the value of this sensor is substituted and marked with a ΄ (e.g. 0.7΄ C). a) Show raw temperature sensor values in user panel by pressing enter key in INFORMATION menu (see figures below). Return air temp sensor replaced (0.7΄ C) Return air temp sensor raw (23.8 C) 12.Starconomy is on by default for additional prefix ranges TEMU, DAYU, and SILU. 13.Possibility to switch and keep settings between C/F for SILU, TEMU, and CAIU. 14.Temperature sensor alarms will not be activated if sensors can be substituted. Limitation: a) max. 3 concurrent failing sensors. b) both Tsup sensors failing. 15.Lowering the Pmem pass criteria under CA PTI to 79Mbar. (previously 130Mbar) StarView: Please note it is required to update the StarView program to the latest version in order to be able to read all the new events and alarms, otherwise it will just show “unknown” in the log. Updating the program can be done by opening your StarView program and clicking on “Help”. Here your will find “Check for updates”. Click on this and it will update to the latest version 3.19.224.0. Bjerndrupvej 47 • 6360 Tinglev, Denmark • CVR/SE no.: 13 82 37 74 www.mcicontainers.com • service@starcool.com • +45 7364 3400
Download PDF file