QUICK GUIDE MOTOR CONTROLLER Type TR-EM-208 123 4 123 4 123 4 DIP position: = Off L I N A K = D O A n N M A R K Start Condition: (DIP 4) On = Only in opposite direction Off = In both directions On O Control Mode: (DIP 3) On = Impuls Control Off = Continous Control On O Current limit range 1-5A: (DIP 1 & 2) LA12; LA14; LA22; LA23; LA31; LA35 On O 123 4 123 4 123 4 1234 5 6 7 8 9 10 GND OUT IN STOP ERROR-LED BL BR +- Actuator +- PSU 12V/24V *)Actuator LA12: (+) = BR, (-) = BL Color codes R = Red S = Black V = Violet BL = Blue BR = Brown GU = Yellow GR = Green OR = Orange HV = White none = No wire 567 OR GR R 567 R GR BL 567 Current limit range 5-10A:(DIP 1 & 2) LA25; LA28; LA30; LA32; LA34 On O Current limit range 10-25A:(DIP 1 & 2) LA36; LA37 On O Accelleration Ramp: Limit fine adjustment 0-3 sek. Decelleration Ramp: Limit fine adjustment 0-3 sek. Current limit: Limit fine adjustment. Control Logic: NPN (LINAK Controls) Control Logic: PNP Control: HB41 Control: DP1E; TP1E Control: Rocker 1A 1 For detailed instructions please refer to the Instruction manual at www.linakthirdparty.com Specifications subject to change without prior notice. It is the responsibility of the product user to determine the suitability of the products for a specific application. LINAK Danmark will at point of delivery replace/repair defective products covered by the warranty if promptly returned to LINAK Danmark. No liability is assumed beyond such replacement/repair. 1B The specified product is produced by Electromen OY Distributor: LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 86 80 36 11 - www.linak.dk