3. Connect the column kit LC3 Column Kit | 3 Depending on how many columns there are in the kit, follow the corresponding guide on the following pages. Single and 2-Parallel kits 1. Connect the first lifting column using the angled motor cable 1 . Remember to install the locking ring on the female mini-fit connector to keep the cables fastened. Then connect to the control box 2 ; channel 2 1.1. If 2 columns: Connect the 2 nd column to channel 4 in the control box 2 . 2. Connect the control box 2 from the center socket to the junction box 3 , port 1. Use the straight cable with modular plugs. 3. Connect the operating panel 4 to the junction box 3 , port 4. 4. Mount the blind plugs on the open ports of the junction box 3 and inside the control box 2 . Close the lid tightly on the control box 2 and close the junction box 3 by sliding the cable lock into place. 5. Check that the voltage stated on the label on the control box 2 corresponds to the mains power. Plug in the mains cable 5 and switch on the power. 6. Press and hold both arrows on the operating panel 4 until the column(s) is/are fully retracted and stops running. The system is ready. Single LC3 kit 3 2-Parallel LC3 kit 4 2 5 1