Page number 66
CB16 Phased-out products | 66 CB16 is part of the LINAK ® OpenBus™ product range. It is a powerful control box with either traditional transformer solution or Switch Mode Power Supply.The universal Switch Mode Power Supply makes the control box adaptable to the worldwide market irrespective of the input voltage. Usage Duty cycle: Usage temperature: Storage temperature: Compatibility: Approvals: 10%, 2 minutes continuous use followed by 18 minutes not in use +5 °C to +40 °C -10 °C to +50 °C LA27 (no feedback/encoded feedback), LA31, LA34, LA43, LA44, BL1, and BL4 IEC60601-1 ANSI/AAMI ES60601-1 CAN/CSA-22.2 No 60601-1 Recommendations NOTE - HOT PLUGGING Removing or adding any OpenBus TM cables are not allowed when the CB is powered by mains supply! If needed anyway follow the below procedure: 1. Remove mains and wait 5 sec. 2. Mount or dismount the required cables If this procedure is NOT followed it may result in a damaged OpenBus TM driver circuit. The risk of a damaged circuit increases if the accessory has a high start current (in rush current). NOTE - Use of internal mains signal in software or on OpenBus TM Please note when using the internal mains signal on control boxes with SMPS that the mains signal may take up to 6 seconds before disappearing after mains has been removed. Battery operation: BATTERY LEVELS Battery High: > 20 V Battery Medium: 18 - 20 V Battery Low: < 18 V - normal - alarm - critical
Page number 67
Phased-out products | 67 If the battery voltage is at ‘Medium level’ a battery alarm beeps as long as a key is activated. (Medium level means that battery charging is necessary to maintain the best possible lifetime). • If the battery voltage is at ‘Low level’, the battery alarm function shuts down all movement immediately. The OpenBus TM is still active for approx. 15 seconds. (If trying to operate the system anyway, the battery could get deep drained or the actuator system could get damaged. • When at low battery level (which is critical), there is a risk that the processor will incorrectly monitor the end of stroke. • Crashing the actuator could be a result. • The CB16 with battery back-up only commences battery charging when it is connected to the mains. • For more information about the batteries, please contact LINAK. Before startup of CB16OBF Due to the microprocessor in CB16OBF the control box has to be initialised before startup. Initialisation will in most cases be possible pressing H0 and H1 or H10 and H11 on a hand control. Initialisation depends upon the software description so please obtain a description of the initialisation procedure from your local LINAK dealer. • If an actuator is replaced, the microprocessor always has to be initialised before use (actuators with reed/ hall). • If re-programmed please ensure that the correct software is used. Warnings If backlight supported HB is used: • When CB16 OBL or OBF is powered by mains voltage: At no operation of the HB the backlight in the HB is dimmed. If an HB button is activated the backlight illuminates fully. When the HB button is released the light is dimmed again after approx. 10 - 15 sec. • When CB16 OBL or OBF is powered by battery: At no operation of the HB theres is no backlight in the HB. If an HB button is activated the backlight illuminates fully. When the HB button is released the backlight turns off.