Page number 68
Phased-out products | 68 1 st failure safe monitoring: • Failure indication: all ACO LED’s are blinking The CB16 buzzer is shortly beeping if a hand control is activated The error can be reset by activating H0 and H1 OR H10 and H11 on a hand control. Compatibility – CB16 OBL: • Using actuators with feedback on CB16 OBL are not supported. If used anyway it will not work properly. The reason is that feedback signals (e.g. Hall signals) is positioned at the same PINS as analogue stop signals - when using no feedback. CB16OBF SMPS - Actuator combinations and/or customized software • Due to the high power from the CB16OBF SMPS, it is highly recommended to validate the system to guarantee the lifetime of connected actuators. Especially when using customized software and/or actuator combinations which do not comply with the LINAK compatibility list - for further questions please contact your local LINAK contact.
Page number 69
Phased-out products | 69 CB20 CB20 is a platform which offers a unique safety concept, logging off service data and it is possible to connect a variety of accessories to the control box. CB20 consists of 3 modules: • CP20 = Control Power • CU20 = Control Unit • BA20 = Battery Usage Compatible with specific versions of LA23, LA27C, LA31, LA34, LA40, LA43, LA44 and BL1 • Duty cycle: 10% ˜ max. 2 min. continuous use followed by 18 min. not in use • Ambient temperature +5˚ to + 40˚C • Approvals: IEC60601-1, ANSI / AAMI ES60601-1, CAN/CSA-22.2 No 60601-1 Information CB20 is delivered in 3 separate units - CU20 + CP20 + BA20. The units are not assembled at LINAK A/S. Recommendations HOT PLUGGING • Removing or adding any OpenBus ™ cables are not allowed when the CB is powered by mains supply! If necessary anyway follow the below procedure: 1. Remove mains and wait 5 sec. 2. Mount or dismount the required cables If this procedure is NOT followed it may result in a damaged OpenBus driver circuit. The risk of a damaged circuit increases if the accessory has a high start current (in rush current). • Please note mains cable must be ordered separately. Battery running • If battery capacity is under 50% a “bip” sound is given for 2 seconds, when a handset key is pressed. • If the system is activated and the mains plug is pulled out, the system will stop. • In the opposite case, if the system is running using battery power and the mains plug is then plugged in, the system will continue running. • The charging indicator can blink if the system operates with a high load causing the voltage to drop and because of this the batteries will start to charge. • The CB20 with battery back-up only commences battery charging when it is connected to the mains.