Page number 6
Linear Actuator LA25 | 6 During operation, please be aware of the following: • Listen for unusual sounds and watch out for uneven running. Stop the actuator immediately if anything unusual is observed. • Do not sideload the actuator. • Only use the actuator within the specified working limits. • Do not step on or kick the actuator. When the equipment is not in use: • Switch off the mains supply in order to prevent unintentional operation. • Check regularly for extraordinary wear. Classification The equipment is not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide. Warnings • Do not sideload the actuator. • When mounting the actuator in the application ensure that the bolts can withstand the wear and that they are secured safely. • If irregularities are observed, the actuator must be replaced. Recommendations • Do not place load on the actuator housing. • Prevent impact or blows, or any other form of stress to the housing. • Ensure that the cable cover is mounted correctly. Use 3.5 Nm torque. • Ensure that the duty cycle and the usage temperatures for LA25 actuators are respected. • Ensure that the cable cannot be squeezed, pulled or subjected to any other stress. • Furthermore, it will be good practice to ensure that the actuator is fully retracted in the “normal” position. The reason is that there will be a vacuum inside the actuator if it is extended which over time can lead to water entering the actuator.
Page number 7
Linear Actuator LA25 | 7 Features • Protection class: IP66 for outdoor use (dynamic). Furthermore, the actuator can be washed down by a high pressure cleaner (IP69K - static) • Heavy-duty aluminium housing for harsh conditions • Mechanical endstop • Guided nut • Static safety factor: 2.0 • Noise level: Max. 58.5 dB(A) at nominal voltage and with no load, according to EN ISO 3743-1 Options in general • 12 / 24 V DC Brushed motor • Load from 600 N - 2,500 N • Max. speed 2.5 to 25 mm/sec. depending on load and spindle pitch • Stroke length from 20 mm to 600 mm (Zero Point: 100 to 600 mm) • Steel or stainless steel back fixture and piston rod eye • Colour: Dark olivish grey or black • Safety nut in push or pull (2,500 N version: only safety nut in push; 600 N version: no safety nut) • Exchangeable cables in different lengths • Analogue or digital feedback for precise positioning • Endstop reached signals • Built-in Zero Point or endstop switch initialisation principle • Hall effect sensor for precise positioning • Special anodised housing for extreme environments • CCC Ex, IECEx/ATEX certified for Zone 21 • IC options (see specific interface user manuals at the TECHLINE webpage for Connection Diagrams and I/O Specifications) including: - I/O - IO-Link - LIN bus - CAN bus J1939 - CANopen - Modbus RTU - Modbus TCP/IP - Ethernet/IP - Profinet • PC configuration tool (Actuator Connect ™ and BusLink) Usage • Duty cycle is max. 20% (4 min. drive and 16 min. rest) The duty cycles and full performance are valid for operation within an ambient temperature of +5°C to +40°C • Ambient operating temperature: -40°C to +85°C (for IECEx/ATEX: T135 -25°C to +65°C; T125 -25°C to +55°C ) • Storage temperature: -55°C to +105°C For more information about interfaces, please see the respective user manual on LINAK.com.