Page number 6

Linear Actuator LA33 | 6 Technical specifications: 12 V motor: Type Thrust max. Push/ Pull (N) 33090xxxxxxxxA. 33150xxxxxxxxA. 33150xxxxxxxxA. 33200xxxxxxxxA. 33200xxxxxxxxA. 5000 3500 2250 1500 500 Self- lock max. Push (N) 5000 3500 2250 1500 500 Self- lock max. Pull (N) 5000 3500 2250 1500 500 Spin- dle Pitch (mm) /Gear 9 / A 15 / A 15 / B 20 / B 20 / C *Typical speed (mm/s) No load 9 15 23 34 68 Full load 6 9 15 24 52 Stroke length (mm) in steps of 50mm Min. Max. 100 - 300** 100 - 400** 100 - 500** 100 - 600 100 - 600 *Typical Amp. (A) No load 2.8 2.8 2.8 2.0 5.0 Full load 10 10 10 10 12 End- play mm +/- 1 1.25 1.25 2.5 2.5 24V motor: Type 33090xxxxxxxxB. 33150xxxxxxxxB. 33150xxxxxxxxB. 33200xxxxxxxxB. 33200xxxxxxxxB. Thrust max. Push/ Pull (N) 5000 3500 2250 1500 500 Self- lock max. Push (N) 5000 3500 2250 1500 500 Self- lock max. Pull (N) 5000 3500 2250 1500 500 Spin- dle Pitch (mm) /Gear 9 / A 15 / A 15 / B 20 / B 20 / C *Typical speed (mm/s) No load 9 15 25 35 80 Full load 7 13 21 30 72 Stroke length (mm) in steps of 50mm Min. Max. 100 - 300** 100 - 400** 100 - 500** 100 - 600 100 - 600 *Typical Amp. (A) No load 1.8 1.8 1.8 1.8 3 Full load 6.5 7.0 6.6 6.5 7 End- play mm +/- 1 1.25 1.25 2.5 2.5 48 V Motor: Type 33090xxxxxxxxJ. 33150xxxxxxxxJ. 33150xxxxxxxxJ. 33200xxxxxxxxJ. 33200xxxxxxxxJ. Thrust max. Push/ Pull (N) 5000 3500 2250 1500 500 Self- lock max. Push (N) 5000 3500 2250 1500 500 Self- lock max. Pull (N) 5000 3500 2250 1500 500 Spin- dle Pitch (mm) /Gear 9 / A 15 / A 15 / B 20 / B 20 / C *Typical speed (mm/s) No load 9 15 25 35 80 Full load 7 13 21 30 72 Stroke length (mm) in steps of 50mm Min. Max. 100 - 300** 100 - 400** 100 - 500** 100 - 600 100 - 600 *Typical Amp. (A) No load 0.9 0.9 0.9 0.9 0.9 Full load 3.2 3.5 3.3 3.2 3.5 End- play mm +/- 1 1.25 1.25 2.5 2.5 * The typical values can have a variation of ± 20% on the current values and ± 10% on the speed values. Measurements are made with an actuator in connection with a stable power supply and an ambient temperature at 20 °C. ** There are limitations on the stroke length if you need full load, please see “Load vs. stroke length” on page 5. Please note that all actuators featuring ‘IC Advanced with softstop towards end stop’ or ‘IC Parallel’, ‘LINBUS’, ‘CAN bus’, ‘MODBUS’ will run at a regulated speed, which is typically around 80% of the nominal speed.

Page number 7

Linear Actuator LA33 | 7 It is possible to maintain an endstop reached signal, after the actuator has stopped, with other feedback systems than those available with Integrated Controller. -This comes at the cost of the better self-lock and the improved ability to prevent back-drive, which a shorted motor provides. It requires that supply on both brown, blue, red and black wires is maintained. See conection diagrams for"Actuator with Endstop Reached" for connections. Gear ratios: Type Gear ratio 9mm spindle 15mm spindle 20mm spindle Gearbox 33xxxxxxxxxxxxxxxxxA. 33xxxxxxxxxxxxxxxxxB. 1:67 5000 N 3500 N - 1:39 - 2250 N 1500 N 33xxxxxxxxxxxxxxxxxC. 1:16 - - 500 N

    ...