Page number 6
Linear Actuator LA76 | 6 During operation, please be aware of the following: • Listen for unusual sounds and watch out for uneven running. Stop the actuator immediately if anything unusual is observed. • Do not sideload the actuator. • Only use the actuator within the specified working limits. • Do not step on or kick the actuator. When the equipment is not in use: • Switch off the mains supply in order to prevent unintentional operation. • Check regularly for extraordinary wear. Classification The equipment is not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide. Warnings • Do not sideload the actuator. • When mounting the actuator in the application ensure that the bolts can withstand the wear and that they are secured safely. • If irregularities are observed, the actuator must be replaced. Recommendations • Do not place load on the actuator housing. • Prevent impact or blows, or any other form of stress to the housing. • Ensure that the cable cover is mounted correctly. Use 3.5 Nm torque. • Ensure that the duty cycle and the usage temperatures for LA77 actuators are respected. • Ensure that the cable cannot be squeezed, pulled or subjected to any other stress. • Furthermore, it will be good practice to ensure that the actuator is fully retracted in the “normal” position. The reason is that there will be a vacuum inside the actuator if it is extended which over time can lead to water entering the actuator.
Page number 7
Linear Actuator LA76 | 7 Features • Protection class: IP66 for outdoor use (dynamic). Furthermore, the actuator can be washed down by a high pressure cleaner (IP69K - static) • Highly efficient acme thread spindle • Hand crank for manual operation • Integrated brake with high self-lock ability • Endplay: max. 3.5 mm • Non-rotating piston rod eye • Noise level: 73 dB (A). Measuring method: DS/EN ISO 3746 (actuator not loaded) • Built-in Zero Point positioning • Heavy duty aluminium housing for harsh conditions • Hall effect sensor for precise positioning • Current monitoring Options in general • 24 / 48 V DC Brushless motor • Load from 500 N - 6,800 N depending on gear ratio and spindle pitch • Max. speed 160 mm/sec. depending on gear ratio and spindle pitch • Stroke length from 100 to 1,200 mm • Back fixture turnable in steps of 30 degrees • Exchangeable cables in different lengths • When ordering AISI (304 and up) piston rod eye and back fixture, stainless steel screws are automatically included • Endstop reached signals • IC options (see specific interface user manuals at the TECHLINE webpage for Connection Diagrams and I/O Specifications) including: - I/O - Ethernet/IP - Modbus TCP/IP - Modbus RTU - IO-Link - CAN bus - CANopen • PC configuration tool (Actuator Connect™)