Features/Options/Usage DESKLIFT™ DL20 IC | 3 Features • Two-part motor-housing column • PLUS™: No visible gliding pads • In combination with SMPS: Parameter With SPMS001 / SMPS002 / SMPS006 Max. speed (unloaded) 38 mm/s Max. load (per column) 500 N Self-lock (per column) 500 N • Standard installation dimension: 645 mm • Standard stroke length: 500 mm • Weight: Approximately 6.8 kg per column • Dimensions column: 60 x 90 mm (see also Dimension drawings) • Dimension motor housing: 177 x 97 x 46 mm • Four M6 and two M8 threaded holes in bottom plate for mounting of feet • Colour: Available in black (RAL 9005), grey (RAL 9006) or white (RAL 9016) • Low noise level Options • Available in custom colours • Available with trim rings in black, grey or white • Available with bench bracket Usage • 2 parallel drive with one DL20 IC Control and one DL20 IC Companion, and an external power supply (SMPS001 (230 V), SMPS002 (120 V) or SMPS006 (Universal)) • Duty cycle: 10% ≈ 2 minutes continuous use at full load, followed by 18 minutes pause • For indoor use in dry locations Parameter Operation Storage and transportation Temperature 10 to 40 °C -10 to +50 °C Relative humidity 20% to 80% - non-condensing 20% to 80% - non-condensing Atmospheric pressure 700 to 1060 hPa 700 to 1060 hPa Altitude Max. 2000 m Max. 2000 m • Compatible with DESKLINE ® controls • Compatible with Battery Box BA001 • ompatible with the Kick & Click™ top frame • System compliance, see the Declaration of Conformity in the User Manual Be aware that when a desk panel DP1CS, DPF1C, DPF1D, or DPT is used, the light intensity must be configured to 50% before use.