Page number 4

Features and options CB6S MK2 | 4 Power supply: Standby current consumption, SMPS: Channels: Varistor: Colour: Weight: Battery charger: Charging indicator: Battery alarm: EOP: Housing type: IP rating: Operation: Max. current, total: μ-processor: Management: Speed control: Start/stop: Light background: Control concept: Service monitor: External battery connection (BA18): Accessories: SMPS Universal: 200 W, 100-240 VAC 50/60 Hz Approx. 0.8 W (230 V) 4 For input voltage protection Light grey (RAL7035) 700 g Yes Supported Yes, at medium battery level (19.6 V) Implemented in standard software V-0 IPX6 Real parallel (feedback possible) 10 A (EOP supported) 128 kB (supports more complex software, for instance true parallel operation, feedback is possible) With full software power management Possible with special software (common for all channels) Soft start/direct stop Background light in hand controls supported (Vpermanent) Relays (fully software-controlled EAS protection) Yes, supported Capacity: 1.3 Ah, must be ordered separately OpenBus ™ accessories

Page number 5

Usage CB6S MK2 | 5 Operating temperature: +5 °C to +40 °C Storage temperature: -10 °C to +50 °C Relative humidity: 20% to 80% - non-condensing Atmospheric pressure: 700 to 1060 hPa Meters above sea level: Max. 3000 meters Mains supply grid should be limited to the highest prospective short circuit current of 1500 A. Demands to mains supply safety for the application in accordance with IEC 60601-1 ed. 3.2, § 8.11.5 Approvals: IEC 60601-1 ANSI/AAMI ES 60601-1 CAN/CSA-C22.2 No. 60601-1, Australian, Canadian deviation

    ...