Page number 6
UBL4 | 6 4. Patient returns to the bed, activates the bed sensor and guiding light is back on max intensity. When the patient enters the bed again, the guiding light will dim after 10 seconds and turn off after 10 minutes. 5. The sensor field of vision is obstructed, in this case by the bed sheets, and will not function. 6. The guiding light will only turn on in poorly lit rooms. (Guiding light will turn on when night threshold is below approximately 35 lux. The guiding light will not turn on when light is above approximately 75 lux.
Page number 7
Ordering example UBL Version 4M 4M = Version Not used 0 0 = None Functionality XX 01 = UBL Motion sensor XX 01 = Motion sensor Light sensor mode XX 01 = Light sensor Standard IP-degree XX 00 = Standard 4 4 = IPX4 Colour - 2 2 = Grey (RAL7035) Mounting 0 0 = Screw Cable type 1 1 = Modular type PVC Cable length X 1 = Cable length 500mm 2 = Cable length 1250mm 3 = Cable length 2500mm Not used Not used Not used 0 0 = None 0 0 = None 0 0 = None Chosen item number: UBL4M0XXXXXXXX4-201X000 UBL4 | 7