Page number 4

Features and options Load in push: Load in pull: Dynamic push and pull: Housing colour: Protection class: Motor: Stroke length: LA40 | 4 1,500 N, 4,000 N, 6,000 N, 8,000 N LA40 Std. + LA40 HP without spline, up to 2,000 N LA40 PL + LA40 QR (not suitable for pull) Actuators are designed for push or pull applications. If a combination is required, please contact your local LINAK salesperson. Light grey, RAL 7035 Black, RAL 9005 (special article) IPX6, IPX6 Washable DURA™ (manual lowering only IPX6) Std. motor (B), HP motor (G), PL motor (F) Standard and High Performance version: 1,500 N: 50 - 405 mm (in steps of 5 mm) (from 410-600 mm stroke is only for special articles) 4,000 N: 50 - 300 mm (in steps of 5 mm) 6,000 N: 50 - 200 mm (in steps of 5 mm) 8,000 N: 50 - 250 mm (in steps of 5 mm) Patient Lift version: 8000 N: 50 - 300 mm (in steps of 5 mm) with SF 2.0 6000 N: 50 - 400 mm (in steps of 5 mm) with SF 2.0 (in accordance with ISO 10535) Minimum built-in dimensions: Positioning options: Quick release: Quick release Damper: Manual lowering: Longer stroke lengths are possible - please contact your nearest sales office. This may have influence on the safety factor. Tolerance on stroke length: ± 2 mm Standard and High Performance version: Stroke + 170 mm With mechanical spline, stroke + 180 mm With QR, stroke + 180 mm With mechanical spline and QR, stroke + 190 mm With ratchet spline and QR, stroke + 180 mm With QR Damper, add 15 mm to BID for all QR versions Patient Lift version: Stroke + 274 mm; S ≤ 300 mm Stroke + 294 mm; S ≤ 400 mm Tolerance on built-in dimension: ± 2 mm Dual Hall with power switches and dual Hall analogue, encoded with signal switches (16 pulses per rev.) Potentiometer input 0-5 Volt Internal, only for LA40 Standard versions Internal, only for LA40 Standard versions Only for Patient Lift version

Page number 5

Noise level: Nut: Safety nut: Spline: Built-in electrical limit switch: Built-in endstop: Exchangeable cable: Safety factor is: Weight: Static bending moment: Feedback type: LA40 | 5 ≤50 dB (A) Guided spindle nut for Standard and High Performance Non-guided spindle nut for Patient Lift version (ML) Standard Mechanical spline Ratchet spline (for Standard, PL, HP and QR versions only) • Required activation force during inward operation: 50-100 N • For QR versions: Force required to manually activate spline (actuator not in operation): Static pull force = 300-550 N Signal switch or power switch Mechanical (for safety only) Minifit plug Up to 2.5 Beds = 2.0 Medical (Standard and HP versions) = 2.5 in accordance with standard Medical (PL version) = 2.0 in accordance with standard > 2.0 kg (depending on version and specification) No side load allowed None, dual Hall (digital or encoded dual Hall) Potentiometer (only for QR version) Usage Duty cycle: Usage temperature: Storage temperature: Compatibility: Relative humidity: Atmospheric pressure: Height above sea level Flammability rating: Approvals: 10%, 2 minutes continuous use, followed by 18 minutes not in use +5 °C to +40 °C -10 °C to +50 °C Compatible with LINAK control boxes. Please contact LINAK. 20% to 80% - non-condensing 700 to 1,060 hPa Max. 3,000 meters UL94V-2 IEC 60601-1 ANSI/AAMI ES60601-1 CAN/CSA-C22.2 No 60601-1 The product is not designed for dynamic load changes (from push to pull or vice versa). If the application design requires a product with a dynamic load change capability, please contact LINAK for investigation of product feasibility or guidance.

    ...