Usage • Duty cycle: 10%, 2 minutes continuous use followed by 18 minutes not in use • Ambient temperature: +5o to +40o C • Storage temperature -40o to +70o C • Compatible with LINAK control boxes. Please contact LINAK. • Approvals: IEC 60601-1, ANSI/AAMI ES60601-1 and CAN/CSA-22.2 No 60601-1 Technical specifications LA30 | 4 New type Spindle pitch(mm) Load max.(N) Push Load max.(N) Pull *Self-lock max. with/without brake (N) Typical speed 0/ full load (mm/s) Stroke length (mm) Typical amp.at ull load 12V 24V 307xx0-4xxxx0/5xx 303xx0-4xxxx0/5xx 302xx0-4xxxx0/5xx 301xx0-xxxxx0/5xx 307xx0-4xxxx1/2xx 303xx0-4xxxx1/2xx 302xx0-4xxxx2xx 302xx0-4xxxx1xx 301xx0-xxxxx1/2xx 307xx0-4xxxx4xx 303xx0-4xxxx4xx 302xx0-4xxxx4xx 301xx0-xxxxx4xx 12 1000 1000 1000/0 48/24 50 100 150 200P 250 300 350 400P 14 7 9 1500 1500 1500/400 42/20 50 100 150P 200 250 300P 350 400 14 7 6 2000 2000 2000/500 18.5/14 50 100P 150 200P 250 300 350 400P 14 7 3 3000 3000 3000/3000 16/9 50P 100P 150 200P 250 300 350 400 14 6.4 12 1000 1000 1000/0 65/35 50 100 150 200P 250 300 350 400P 20 10 9 1800 1800 1800/0 52/25 50 100 150P 200 250 300P 350 400 20 10 6 2000 2000 2000/500 34/20.3 50 100P 150 200P 250 300 350 400P 18 - 6 2400 2400 2400/500 34/20.3 50 100P 150 200P 250 300 350 400P 9 3 3500 3000 3500/3500 17/9.5 50P 100P 150 200P 250 300 350 400 18 9 12 1000 1000 1000/0 26/20 50 100 150 200P 250 300 350 400P - 2.5 9 2000 2000 2000/0 20/13 50 100 150P 200 250 300P 350 400 - 4.4 6 3000 3000 3000/2000 13.8/7 50 100P 150 200P 250 300 350 400P - 4 3 4000 3000 4000/4000 7/4.5 50P 100P 150 200P 250 300 350 400 - 5.5