Technical specifications Type 12XX00-1XXX12XX 12XX00-1XXX24XX 12XX00-2XXX12XX 12XX00-2XXX24XX 12XX00-3XXX12XX 12XX00-3XXX24XX Motor voltage (V) Spindle Pitch (mm) Thrust max. Push/Pull (N) Self-lock max. (Push) (N) Self-lock max. (Pull) (N) *Typical speed (mm/s) No Full load load 12 2 750 750 375 14 5 24 2 750 750 375 14 6 12 4 300 300 150 27 16 24 4 300 300 150 27 16 12 6 200 200 100 40 28 24 6 200 200 100 40 28 Stroke length (in steps of 30 mm) Min. Max. 40 - 130 40 - 130 40 - 130 40 - 130 40 - 130 40 - 130 *Typical Amp. (A) No Full load load 1.75 4.6 0.75 2.2 1.75 2.5 0.75 1.5 1.75 2.2 0.75 1.0 * The typical values can have a variation of ± 20% on the current values and ± 10% on the speed values. Measurements are made with an actuator in connection with a stable power supply and an ambient temperature at 20°C. • Self locking ability To ensure maximum self-locking ability, please be sure that the motor is shorted when stopped. Actuators with integrated controller provide this feature, as long as the actuator is powered. • When using soft stop on a DC-motor, a short peak of higher voltage will be sent back towards the power supply. It is important when selecting the power supply that it does not turn off the output, when this backwards load dump occurs. Stroke and built-in tolerances Platform options Descriptions Stroke tolerance Example for 100 mm stroke BID tolerance 12XX00-XXXXXXXX 12XX02-XXXXXXXX 12XX03-XXXXXXXX All variants All variants +2/-2 mm +2/-2 mm 98 to 102 mm 98 to 102 mm +2/-2 mm +2/-2 mm BID examples 243 to 247 mm 253 to 257 mm Page 5 of 20