Features/Options/Usage DESKLIFT™ DL16 IC | 3 Features • Three-part motor-housing column • In combination with SMPS: Parameter With SPMS001 / SMPS002 / SMPS006 Max. speed (unloaded) 38 mm/s Max. load (per column) 500 N Self-lock (per column) 500 N • Standard installation dimension: 560 mm • Standard stroke length: 650 mm • Weight: Approximately 7.5 kg per column • Dimensions column: 50 x 80 mm (see also Dimension drawings) • Dimension motor housing: 177 x 97 x 46 mm • Four M6 threaded holes in bottom plate for mounting of feet • Colour: Available in black (RAL 9005), grey (RAL 9006) or white (RAL 9016) • Low noise level Options • Available as DESKLIFT™ SetPack Usage • 2 parallel drive with one DL16 IC Control and one DL16 IC Companion, and an external power supply (SMPS001 (230 V), SMPS002 (120 V) or SMPS006 (Universal)) • Duty cycle: 10 % ≈ 2 minutes continuous use at full load, followed by 18 minutes pause • For indoor use in dry locations Parameter Operation Storage and transportation Temperature 10 to 40 °C -10 to +50 °C Relative humidity 20% to 80% - non-condensing 20% to 80% - non-condensing Atmospheric pressure 700 to 1060 hPa 700 to 1060 hPa Altitude Max. 2000 m Max. 2000 m • Compatible with DESKLINE ® controls • Compatible with Battery Box BA001 • Compatible with the Kick & Click™ top frame • System compliance, see the Declaration of Conformity in the User Manual Be aware that when a desk panel DP1CS, DPF1C, DPF1D, or DPT is used, the light intensity must be configured to 50% before use.