Operation of the DPT in connection with DESKLINE® systems DPT features ZERO™ meaning that if the DPT is not being used it will go into standby mode after approx. 10 sec. and the display will be turned off. When activated again only a bar is lightning in the centre of the display as the DPT is locked. For safety reasons the DPT has a locking function. If the DPT is locked, only a bar is lightning in the centre of the display. To unlock the control press ¨S¨ for 1 sec. When the DPT is unlocked, the height will be shown in the display. Now the DPT is active for 2.5 seconds. When pressing one of the keys you can do your adjustment. Hereafter the DPT will be active for 5 seconds. When there are no activations made within the mentioned time slot, the DPT will go in to locking mode again. Also if you press ¨S¨ for unlocking too long, the DPT will unlock but immediately lock again. The Touch Desk Panel is used to operate the DESKLINE® systems. The DPT is divided into parallel and memory drive. The two arrow buttons are used for parallel drive and the last four buttons for memory drive. ↑ = Desk up ↓ = Desk down S = Store memory + unlock 1 = Memory 1 2 = Memory 2 3 = Memory 3 Normal operation: To run the desk up or down, press the ∧ or ∨ button, and keep it pressed until the desk reaches the desired height. The display will count the height as the table is moving and will continually show the height of the desk after stopping. Storing a memory position: Touch the “S” button the display will flash “S” for 3 sec. While the ¨S¨ is displayed, touch the memory button 1, 2 or 3. The display will acknowledge by showing S1, S2 or S3 for 1 sec. To abort a store sequence press the ∧ or ∨ button while the “S” is flashing, or wait the 3 seconds until the display automatically returns to show the height of the desk. Drive to a stored position: Press memory button 1, 2 or 3 and the system will start driving to the desired memory position. Keep the button activated until the position is reached. The display will count the height as it is driving to the memory position. Customizing the DPT digital display Adjust the display to show the correct height: The DPT will show 68 cm or 24.5 inches as the height of the desk as the default setting. It may be necessary to adjust the displayed height due to different thicknesses of desktops etc. To adjust the display touch the ¨S¨ button and the ∧ or ∨ button at the same time until the display shows the actual height of the desk. Changing between cm and inches: Touch the ¨S¨ button for approximately 5 seconds and the unit of measurement will change on the display. The default setting depends on the type chosen. Switching between cm and inch can also be done via the DPF1C configurator.
Download PDF file