Recommendations: • Use only original LINAK mains cables to ensure proper connection to internal charger. • Always use fully charged batteries for learning mode procedures Warning • In order to avoid injury, the emergency stop should be activated in (all) transport situations. • When “learn mode” is used, and channel 2 is pressed instead of channel 1, the CBJ Home will learn a new current limit of nearly 0 Amp. This will make it impossible to run the actuator with channel 2 until a new learn mode has been programmed. CBJ-Home Ordering example: CBJH 1 xx yy 0 0 0 00 4 IP degree: 4 = IPx4 Not used Not used Not used Charger version: 0 = External charger 1 = Internal charger Current cut-off for CH2: 00 = One channel version, ch. 2 not available yy = Value between 2.0A & 5.5A in 0.5A increments (4.0A is displayed as “40” and 5.5A will be “55”) Current cut-off for CH1: xx = Value between 3.0A & 8.0A in 0.5A increments (8.0A is displayed as “80” and 7.5A will be “75” Housing type: 1 = V0 according to UL94 (standard) CBJ type: CBJH