Page number 6
Ordering TECHNOLOGY CBD6 S S = Switch Mode Power Supply CBD6S | 6 FUNCTIONALITY P P = 2 channels C = 3 channels H = 4 channels SEGMENT 0 0 = DESKLINE OPTION 0 0 = Standard APPROVALS 0 0 = Standard furniture approvals 1 = IT standard (EN 62368) ** CHANNELS 2 2 = 2 channels 3 = 3 channels 4 = 4 channels OPTION 0 0 = Standard OPTION A A = Advanced COLOUR - - = Black MAINS VOLTAGE 0 0 = 230 V / 50 Hz, 200 W 1 = 120 V / 60 Hz, 200 W 5 = 100 V / 60 Hz, 200 W (Japanese version) 6 = 100-240 V, 50-60 Hz, 300 W (Japanese version) * 7 = 100-240 V, 50-60 Hz, 300 W (universal) OPTION 0 0 = Standard CLASS 9 9 = Without cable CBD6SP00020A-009 * Only available with CHANNELS option 4 ** Only available with MAINS VOLTAGE option 7 and CHANNELS options 2 and 4 All cables for creating a fully connected DESKLINE ® system must be ordered separately. We offer a range of different versions and lengths. To get information such as ordering number, and colour and length of the cables, please contact your local LINAK.
Page number 7
Dimension drawings CBD6S 200 W CBD6S | 7 32 6 96 A 7 A SECTION A-A 210 38 12 86.5 Hexagon ( M6 nut ) A1/A2 Drawing no. 0759006 Control ports for connection of one or two desk panels or the Anti-Collision TM dongle A1/A2 are parallel ports AC Connection to the mains supply DC Connection to Battery Box BA001 1 and 2 Sockets for 1 or 2 DL/DB Modified By Jan Kring Created By Jan Kring Figure 1 CBD6S (200 W) dimensions and mounting holes (mm) 2024-03-12 Customer No.: SBU - 1 2024-03-11 LINAK Drawing No.: 0759006