CB6 Ordering example: CB6 4 0 4 + 1 0 0 1 9 Cable connection: 9 = Cable socket without GND (Class 2) Power Connector: 1 = Power connector Voltage input: To be defined: 0 = 230 V 1 = 120 V 2 = 100 V Connector: 1 = Mini-fit/Modular jack 0 = Modular plug (spare parts only) Colour: + = Plastics RAL 7016 (dark grey) Number of channels: 1 = ch1 2 = ch3, 4 3 = ch1, 3, 4* 4 = ch1-4* PCB type: 0 = Std. 8 = Std. with 24V charger for BA18 via CH1 or CH2 with T-cable (T-cable = 0964033-xxxx). BA18 not protected against BA18 being deep-drained Protection class: 4 = IPX4 6 = IPX6 Type: Control box CB6 Various information: Mounting of CB on actuators / Mounting of CB separately / Blind plugs / Mains cables / Order volume a) It is possible to mount either LA27 or LA40 onto CB6: Mounting of LA27 to CB6: A mounting clip is included in the BOM of CB6 = item No. 009271002-A. The clip is used to fix LA27 onto CB6 and is included in the CB6 package of each CB6 delivery. This item no. can also be ordered separately as a spare part. Mounting of LA40 to CB6: For mounting LA40 onto CB6, 2 external parts are needed – a mounting clip 0401017-A and an adapter 0401080-A. These are NOT included in the BOM of CB6. These item Nos. can be ordered as a kit including both 0401017 + 0401080. The item No. of the kit is: 40KIT-001. b) When CB6 is to be mounted without being mounted to an actuator, a mounting bracket can be used. The bracket is available in the following versions: chromatised = item No. 9271233 or not chromatised = item No. 9271237. c) It is possible to order blind plugs (500 per bag) for the actuator connections. The item No. is 009271027. d) Mains cables must be ordered separately.