ELEVATE TM | 3 Safeguard Stop Emergency Stop DI11 DI10 DI9 DI8 24 V 0V Analogue Outputs Analogue Inputs URCap wiring diagram for ELEVATE Easy URCap wiring diagram for ELEVATE Easy Safety 24 V EI0 24 V EI1 24 V EI0 24 V EI1 Remote 12 V GRD ON OFF Power PWR GRD 24 V 0 V Configurable Inputs 24 V 24 V CI0 CI4 24 V 24 V CI1 CI5 24 V 24 V CI2 CI6 24 V 24 V CI3 CI7 Configurable Outputs 0 V 0 V CO0 CO4 0 V 0 V CO1 CO5 0 V 0 V CO2 CO6 0 V 0 V CO3 Co7 Digital Inputs 24 V 24 V DI0 DI4 24 V 24 V DI1 DI5 24 V 24 V DI2 DI6 24 V 24 V DI3 DI7 Digital Outputs 0 V 0 V DO0 DO4 0 V 0 V DO1 DO5 0 V 0 V DO2 DO6 0 V 0 V DO3 DO7 Power supply* Power + 24 V GND GND Safety relay(s)* *Power supply and safety/contactor relays are purchased separately LC3 IC pinout Analogue AG AI0 AG AI1 AG AO0 AG AO1 IC I/O LC3 Run out Digital Input Possible UR I/O DO0 - DO7 Run in Digital Input DO0 - DO7 End stop in Digital Output DI0 - DI7 End stop out Digital Output DI0 - DI7 Reserved Orange Reserved Light blue Reserved Violet Reserved Grey Reserved White Power GND + 24 V GND COX = System emergency stop Safeguard Stop Emergency Stop DI11 DI10 DI9 DI8 24 V 0V Analogue Outputs Analogue Inputs URCap wiring diagram for ELEVATE Pro URCap wiring diagram for ELEVATE Pro Safety 24 V EI0 24 V EI1 24 V EI0 24 V EI1 Remote 12 V GRD ON OFF Power PWR GRD 24 V 0 V Configurable Inputs 24 V 24 V CI0 CI4 24 V 24 V CI1 CI5 24 V 24 V CI2 CI6 24 V 24 V CI3 CI7 Configurable Outputs 0 V 0 V CO0 CO4 0 V 0 V CO1 CO5 0 V 0 V CO2 CO6 0 V 0 V CO3 Co7 Digital Inputs 24 V 24 V DI0 DI4 24 V 24 V DI1 DI5 24 V 24 V DI2 DI6 24 V 24 V DI3 DI7 Digital Outputs 0 V 0 V DO0 DO4 0 V 0 V DO1 DO5 0 V 0 V DO2 DO6 0 V 0 V DO3 DO7 Power supply* Power + 24 V GND GND Safety relay(s)* *Power supply and safety/contactor relays are purchased separately Analogue AG AI0 AG AI1 AG AO0 AG AO1 LC3 IC pinout IC I/O LC3 Prop (+) Analogue Input Possible UR I/O AO0/1 Prop (-) Analogue Input AG HALL A Digital Output DI8-11 Encoder HALL B Digital Output DI8-11 Encoder Reserved Orange Reserved Light blue Reserved Violet Reserved Grey Reserved White Power GND + 24 V GND CO0-7 = System emergensy stop Safeguard Stop Emergency Stop DI11 DI10 DI9 DI8 24 V 0V Analogue Outputs Analogue Inputs URCap wiring diagram for ELEVATE Modbus* URCap wiring diagram for Elevate Modbus TCP/IP Safety 24 V EI0 24 V EI1 24 V EI0 24 V EI1 Remote 12 V GRD ON OFF Power PWR GRD 24 V 0 V Configurable Inputs 24 V 24 V CI0 CI4 24 V 24 V CI1 CI5 24 V 24 V CI2 CI6 24 V 24 V CI3 CI7 Configurable Outputs 0 V 0 V CO0 CO4 0 V 0 V CO1 CO5 0 V 0 V CO2 CO6 0 V 0 V CO3 Co7 Digital Inputs 24 V 24 V DI0 DI4 24 V 24 V DI1 DI5 24 V 24 V DI2 DI6 24 V 24 V DI3 DI7 Digital Outputs 0 V 0 V DO0 DO4 0 V 0 V DO1 DO5 0 V 0 V DO2 DO6 0 V 0 V DO3 DO7 Power supply* Power + 24 V GND GND Safety relay(s)* *Power supply and safety/contactor relays are purchased separately Analogue AG AI0 AG AI1 AG AO0 AG AO1 LC3 IC pinout IC RJ45 LC3 Modbus Ethernet RJ45 TCP/IP IC I/O LC3 Run Digital Input Out Run Digital Input In Reserved Yellow Reserved Green Split supply + 24 V Reserved Reserved Reserved Light blue Service Interface Grey Reserved N/A Power GND + 24 V GND *Ethernet cable is not included in the accessory kit.
Download PDF file