EPD Vægelementet - Tillægsfil (EN15804+A1)
LCA Results acc. EN15804+A1:2013 Appendix for MD-23057-EN Valid to: 28-04-2028 This appendix refers to the EPD MD-23057-EN, developed according to EN15804+A2:2019. Results in the appendix communicates LCA results in the format described in EN15804+A1:2013, in order to accommodate a need in the transition period between the two standard revisions. The appendix cannot stand alone, as the reference EPD describes the basis of the assessment. Autoclaved aerated concrete wall D:575 Autoclaved aerated concrete wall D:575, EN15804+A1 ENVIRONMENTAL EFFECTS PER PRODUKT PER M 2 Parameter GWP ODP AP EP POCP ADPE ADPF Caption Unit A1-A3 A4 A5 B1 C1 C2 C3 C4 D [kg CO2-eq.] 2,09E+02 6,26E+01 3,62E+00 0,00E+00 5,66E+00 4,44E+00 6,27E+00 2,53E-01 -2,59E+00 [kg CFC11- eq.] 2,10E-07 7,45E-12 7,66E-13 0,00E+00 4,99E-13 5,28E-13 6,32E-13 7,37E-13 -1,52E-11 [kg SO2-eq.] 1,24E-01 5,26E-02 7,44E-04 0,00E+00 1,93E-02 3,72E-03 9,94E-03 1,51E-03 -5,52E-03 [kg PO43--eq.] 1,85E-02 1,08E-02 1,56E-04 0,00E+00 4,63E-03 7,65E-04 2,28E-03 1,68E-04 -9,48E-04 [kg ethene- eq.] 9,36E-03 -8,99E-04 4,36E-05 0,00E+00 1,83E-03 -6,37E-05 5,09E-04 1,18E-04 -5,23E-04 [kg Sb-eq.] 1,27E-05 6,51E-06 2,44E-08 0,00E+00 4,35E-07 4,61E-07 5,52E-07 2,76E-08 -3,39E-07 [MJ] 1,07E+03 8,36E+02 2,23E+00 0,00E+00 5,59E+01 5,93E+01 7,10E+01 3,37E+00 -3,57E+01 GWP = Global warming potential; ODP = Ozone depletion potential; AP = Acidification potential of soil and water; EP = Eutrophication potential; POCP = Photochemical ozone creation potential; ADPE = Abiotic depletion potential for non- fossil resources; ADPF = Abiotic depletion potential for fossil resources Autoclaved aerated concrete wall D:575, EN15804+A1 RESSOURCE CONSUMPTION PER PRODUKT PER M 2 Parameter PERE PERM PERT PENRE PENRM PENRT SM RSF NRSF FW Caption Unit A1-A3 A4 A5 B1 C1 C2 C3 C4 D [MJ] 9,45E+01 5,87E+01 3,74E-01 0,00E+00 3,92E+00 4,16E+00 4,98E+00 5,24E-01 -7,21E+00 [MJ] 1,57E+02 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 2,29E+02 5,87E+01 3,74E-01 0,00E+00 3,92E+00 4,16E+00 4,98E+00 5,24E-01 -7,21E+00 [MJ] 1,13E+03 8,50E+02 2,41E+00 0,00E+00 5,68E+01 6,02E+01 7,21E+01 3,49E+00 -4,46E+01 [MJ] 5,04E+01 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 1,16E+03 8,50E+02 2,41E+00 0,00E+00 5,68E+01 6,02E+01 7,21E+01 3,49E+00 -4,46E+01 [kg] 2,62E+01 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 3,53E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [m 3 ] 1,18E+00 6,78E-02 8,73E-03 0,00E+00 4,53E-03 4,80E-03 5,75E-03 8,87E-04 -8,49E-03 PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Net use of fresh water Autoclaved aerated concrete wall D:575, EN15804+A1 WASTE CATEGORIES AND OUTPUT FLOWS PER PRODUKT PER M 2 Parameter HWD NHWD RWD CRU MFR MER EEE EET Caption Unit A1-A3 A4 A5 B1 C1 C2 C3 C4 D [kg] 1,14E-03 4,50E-09 1,21E-10 0,00E+00 3,01E-10 3,19E-10 3,81E-10 1,79E-10 -4,34E-09 [kg] 1,43E+01 1,38E-01 4,34E-01 0,00E+00 9,26E-03 9,81E-03 1,17E-02 1,79E+01 -2,38E+01 [kg] 2,88E-02 1,58E-03 6,75E-05 0,00E+00 1,05E-04 1,12E-04 1,34E-04 3,89E-05 -3,44E-03 [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [kg] 1,10E+00 0,00E+00 1,18E+01 0,00E+00 0,00E+00 0,00E+00 5,77E+02 0,00E+00 0,00E+00 [kg] 1,41E-02 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 1,27E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 3,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy Checked and approved by Ninkie Bendtsen, Niras Third party verifier of MD-23057-EN Martha Katrine Sørensen EPD Danmark Appendix to MD-23057-EN | H+H Deutschland GmbH | Side 1 af 1
...