EPD Porebetonblokke - Tillægsfil (EN15804+A1)
LCA Results acc. EN15804+A1:2013 Appendix for MD-23056-EN Valid to: 28-04-2028 This appendix refers to the EPD MD-23056-EN, developed according to EN15804+A2:2019. Results in the appendix communicates LCA results in the format described in EN15804+A1:2013, in order to accommodate a need in the transition period between the two standard revisions. The appendix cannot stand alone, as the reference EPD describes the basis of the assessment. Autoclaved aerated concrete block D:375 Autoclaved aerated concrete block D:375, EN15804+A1 ENVIRONMENTAL EFFECTS PER PRODUKT PER M 2 Parameter GWP ODP AP EP POCP ADPE ADPF Caption Unit A1-A3 A4 A5 B1 C1 C2 C3 C4 D [kg CO2-eq.] 1,48E+02 4,10E+01 2,13E+00 0,00E+00 5,66E+00 2,89E+00 4,09E+00 1,65E-01 -1,50E+00 [kg CFC11- eq.] 3,64E-07 4,89E-12 3,85E-13 0,00E+00 4,99E-13 3,45E-13 4,12E-13 4,81E-13 -8,82E-12 [kg SO2-eq.] 1,07E-01 3,45E-02 4,24E-04 0,00E+00 1,93E-02 2,43E-03 6,48E-03 9,82E-04 -3,24E-03 [kg PO43--eq.] 1,52E-02 7,08E-03 8,82E-05 0,00E+00 4,63E-03 4,99E-04 1,48E-03 1,10E-04 -5,57E-04 [kg ethene- eq.] 7,83E-03 -5,89E-04 2,41E-05 0,00E+00 1,83E-03 -4,16E-05 3,32E-04 7,71E-05 -3,07E-04 [kg Sb-eq.] 9,61E-06 4,27E-06 1,42E-08 0,00E+00 4,35E-07 3,01E-07 3,60E-07 1,80E-08 -1,97E-07 [MJ] 7,29E+02 5,48E+02 1,32E+00 0,00E+00 5,59E+01 3,87E+01 4,63E+01 2,20E+00 -2,06E+01 GWP = Global warming potential; ODP = Ozone depletion potential; AP = Acidification potential of soil and water; EP = Eutrophication potential; POCP = Photochemical ozone creation potential; ADPE = Abiotic depletion potential for non- fossil resources; ADPF = Abiotic depletion potential for fossil resources Autoclaved aerated concrete block D:375, EN15804+A1 RESSOURCE CONSUMPTION PER PRODUKT PER M 2 Parameter PERE PERM PERT PENRE PENRM PENRT SM RSF NRSF FW Caption Unit A1-A3 A4 A5 B1 C1 C2 C3 C4 D [MJ] 1,60E+01 3,85E+01 2,09E-01 0,00E+00 3,92E+00 2,71E+00 3,25E+00 3,42E-01 -4,22E+00 [MJ] 1,48E+02 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 1,64E+02 3,85E+01 2,09E-01 0,00E+00 3,92E+00 2,71E+00 3,25E+00 3,42E-01 -4,22E+00 [MJ] 7,53E+02 5,57E+02 1,37E+00 0,00E+00 5,68E+01 3,93E+01 4,70E+01 2,28E+00 -2,57E+01 [MJ] 4,23E+01 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 7,95E+02 5,57E+02 1,37E+00 0,00E+00 5,68E+01 3,93E+01 4,70E+01 2,28E+00 -2,57E+01 [kg] 4,69E+01 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [m 3 ] 6,09E-01 4,44E-02 5,15E-03 0,00E+00 4,53E-03 3,13E-03 3,75E-03 5,78E-04 -4,95E-03 PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Net use of fresh water Autoclaved aerated concrete block D:375, EN15804+A1 WASTE CATEGORIES AND OUTPUT FLOWS PER PRODUKT PER M 2 Parameter HWD NHWD RWD CRU MFR MER EEE EET Caption Unit A1-A3 A4 A5 B1 C1 C2 C3 C4 D [kg] 2,36E-04 2,95E-09 6,24E-11 0,00E+00 3,01E-10 2,08E-10 2,49E-10 1,17E-10 -2,48E-09 [kg] 1,08E+01 9,07E-02 2,77E-01 0,00E+00 9,26E-03 6,40E-03 7,66E-03 1,17E+01 -1,41E+01 [kg] 2,49E-02 1,03E-03 1,81E-05 0,00E+00 1,05E-04 7,29E-05 8,73E-05 2,54E-05 -1,98E-03 [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [kg] 0,00E+00 0,00E+00 7,68E+00 0,00E+00 0,00E+00 0,00E+00 3,76E+02 0,00E+00 0,00E+00 [kg] 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 8,65E-01 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 [MJ] 2,04E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy Appendix to MD-23056-EN | H+H Deutschland GmbH | Side 1 af 2
Side 2
...