Page number 2
SPECIFICATIONS FlowCon PICV actuator 1 : FlowCon SM.0.0.0.3 (standard) FlowCon SM.0.0.0.4 (standard failsafe) FlowCon SM.0.0.0.6 (BACnet failsafe) Supply voltage: Type: Power consumption: Control signal: Resolution: Feedback: Control mode: Failsafe function: Manuel override: Position indicator: Operation time: Ambient temperature: Humidity rating: Housing material: Protection: CE conformity: Programming: Cable: Calibration: Valve-actuator coupling: Protocol: Interface: Device profile: Baud rates support: Services (BIBBS) supported: Participants: 22-26V AC, 50/60 Hz or 22-26V DC Electrical, Bi-directional synchronous motor SM.0.0.0.3: 2.0VA standby / 5.0VA operating / 12VA max. SM.0.0.0.4/6: 3.5VA standby / 5.0VA operating / 12VA max. Analog 0(2)-10V DC or 0(4)-20mA and digital 3-point-floating or 2-position 1:1000 (0-10V analog) and 1:800 (2-10V analog) Linear signal Auto (equal to analog control signal), 0-10V DC, 2-10V DC or 4-20mA Linear flow, Equal percentage, Linear rotation or Linear signal SM.0.0.0.3: Fail in place SM.0.0.0.4/6: Optional open or close (set on actuator) Yes No SM.3-5: 190 sec (from closed to fully open valve) SM.6: 317 sec (from closed to fully open valve) -10°C to +50°C / +14°F to +122°F 5.95% rH, no condensation UL94 V0-rated plastic IP54 including upside-down mounting EN 60730, class II Programming of all settings on interface with buttons and display or via BACnet Fixed, 5 wires x 0.80 mm 2 / AWG18, halogen free, 1 meter / 3 ft Additional for BACnet versions: Fixed, 3 wires x 0.80 mm 2 / AWG18 halogen free, 1 meter / 3 ft Automatic at startup Easy snap coupling BACnet MS/TP EIA-485 / RS-485 BACnet Application Specific Controller (B-ASC) type server 9600, 19200, 38400 and 76800 DS-RP-B, DS-WP-B, DM-DDB-B, DM-DOB-B and DM-DCC-B Up to 32 recommended, max. 127 participants Note 1: FlowCon warranty is voided using other actuators than supplied or recommended by FlowCon International. Tech note · FlowCon SM DN50-250 / 2”-10” · april 2024 · www.flowcon.com Page 2 of 9
Page number 3
DIMENSIONS AND WEIGHT (NOMINAL) Model no. Valve size mm (in) L mm (in) H1 mm (in) H2 mm (in) Weight 2 kg (lb) 50 (2) H1 SM.3.X 65 (2 1/2) 224 (8.82) 252 (9.92) 95.0 (3.74) 14.0 (30.9) 80 (3) 80 (3) SM.4.X 100 (4) 31.0 320 292 135 (68.3) H2 (12.6) (11.5) (5.31) 32.0 - SM.4.3 (70.5 - SM.4.3) 125 (5) L SM.5.X 422 (16.6) 343 (13.5) 180 (7.09) 61.0 (134) 150 (6) 200 (8) SM.6.2 250 (10) 725 (28.5) 472 (18.6) 292 (11.5) 248 (547) Note 2: Weight includes valve and actuator. MODEL NUMBER SELECTION 3 Housing size: 3 = DN50-80 / 2”-3” 4 = DN80-100 / 3”-4” 5 = DN125-150 / 5”-6” 6 = DN200-250 / 8”-10” SM . . .B. .0.0.0 Control range: 0 = 30-800 kPaD / 4.4-116 psid (SM.3 only) 1 = 30-800 kPaD / 4.4-116 psid 2 = 35-800 kPaD / 5.1-116 psid 3 = 50-800 kPaD / 7.3-116 psid (SM.4 only) P/t plug requirements: B = p/t plugs (standard) Type of actuator: 0 = no actuator 3 = display (FlowCon SM.0.0.0.3) 4 = display and failsafe (FlowCon SM.0.0.0.4) 6 = display, BACnet and failsafe (FlowCon SM.0.0.0.6) Example: FlowCon SM.3.1.B.4.0.0.0 = SM DN50-80 body for 30-800 kPaD with p/t plugs and failsafe actuator. Note 3: Model no. and pressure range are indicated on label affixed to body. Tech note · FlowCon SM DN50-250 / 2”-10” · april 2024 · www.flowcon.com Page 3 of 9