Page number 4

SPECIFICATIONS FlowCon PICV actuators FlowCon Actuator 2 Supply voltage Type Power consumption Control signal Feedback Failsafe function FN.0.2 FH 24V AC/DC ±10%, 50/60Hz Electrical, bi-directional synchronous motor 24V AC: 0.9VA standby / 2.5VA operating / 4.7VA max. 24V DC: 0.75W standby / 1.2W operating / 2.2W max. 24V AC: 1.5VA standby / 6VA operating / 8.5VA max. 24V DC: 0.6W standby / 2.6W operating / 4.1W max. Analog 2-10V DC, <0.5mA Yes, control signal Fail in place Fail in place Auto stroke Operation time Yes max 22 sec/mm max 22 sec/mm Ambient temperature 0°C to +50°C / +32°F to +122°F Media temperature 0°C to +120°C / +32°F to +248°F Humidity rating 0.85% rH, no condensation Protection Cable IP54 including upside-down, class III, indoor use only Fixed, 5 wires x 0.50 mm 2 , 1.5 m / 5 wires x AWG20, 4.9 ft Closing point detection Yes Weight 0.25 kg / 0.55 lb 0.30 kg / 0.67 lb Note 2: FlowCon warranty is voided using other actuators than supplied by FlowCon International. FH.1 24V AC: 2.6VA standby / 7.9VA operating / 9VA max. 24V DC: 1.2W standby / 3.7W operating / 4.5W max. Optional open or close (set on actuator) max 22 sec/mm (failsafe: 5sec/mm) 0.34 kg / 0.75 lb M30 x 1.5 FlowCon FN.0.2 M30 x 1.5 FlowCon FH/FH.1 Tech note · FlowCon FIT-G · november 2024 · www.flowcon.com Page 4 of 15

Page number 5

SPECIFICATIONS FlowCon Intelligent Interface Supply voltage: Power consumption: Cable, 3 groups: • Group 1: • Group 2: • Group 3: Communication standard: Control signal: Output signal: Humidity rating: Protection: Housing material: CE conformity: Protocol: Interface: Device profile: Baud rates supported: Services (BIBBS) supported Participants: Load: 24V AC/DC 4W fixed, 1 wire with quick-connector, 3 meter / 9 ft (T1) fixed, 1 wire with quick-connector, 1 meter / 3 ft (T2) fixed, 3 wires, 0.6 meter / 2 ft (analogue actuator communication) fixed, 2 wires 0.6 meter / 2 ft (power and ground) fixed, 3 wires 0.6 meter / 2 ft (BACnet BMS communication) fixed, 1 wire with quick-connector, 1 meter / 3 ft (P1) fixed, 1 wire with quick-connector, 1 meter / 3 ft (P2) fixed, 3 wires, 0.6 meter / 2 ft (BACnet actuator communication - not in use on FlowCon FIT-G) RS485 2-10V DC 2-10V DC 5.95% rH, no condensation IP54 including upside-down mounting UL94 V0-rated plastic Yes BACnet MS/TP EIA-485 / RS-485 BACnet Application Specific Controller (B-ASC) type server 9600, 19200, 38400,57600, 76800 and 115200 DS-RP-B, DS-WP-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DS-RPM-B and DM-RD-B Up to 32 recommended, max. 127 participants 1/8 unit load Temperature sensors (T1 and T2) Supply voltage: Cable: Signal output: Media temperature: Working pressure: Housing material: Protection: Probe length: Probe diameter: CE conformity: Connection: NA No cable, but with quick-connector Resistive -20°C to +120°C / -4° to +248°F 40 bar / 580 psi 304 stainless steel IP65 12.7 mm / 0.5 in (use of sensor pocket is recommended) 6 mm / 0.236 in Yes 1/4” ISO Performance data: • Sensor type: • Accuracy: • Linearity: • Long time stability: • Response time: PT1000 0.5% FS (Full Scale) ±0.5% FS (Full Scale) 0.1% FS (Full Scale) at 50°C (122°F): 2.3 sec / at 90°C (194°F): 5.4 sec. Tech note · FlowCon FIT-G · november 2024 · www.flowcon.com Page 5 of 15

    ...