DIMENSIONS AND WEIGHT (NOMINAL) Model Valve size L1 L2 H1 H2 no. mm mm mm mm mm (in) (in) (in) (in) (in) FUR3.A.x 15 (1/2) 69 178 86 241 (2.7) (7.0) (3.4) (9.5) H3 D E (depth, not shown) mm mm mm (in) (in) (in) 51 76 51 (2.0) (3.0) (2.0) FUR3.B.x 20 (3/4) 71 165 86 226 51 (2.8) (6.5) (3.4) (8.9) (2.0) 76 (3.0) 51 (2.0) 71 185 86 244 53 (2.8) (7.3) (3.4) (9.6) (2.1) FUR3.C.x 25 (1) 76 173 99 251 61 76 51 (3.0) (2.0) (3.0) (6.8) (3.9) (9.9) (2.4) 109 198 104 277 84 (4.3) (7.8) (4.1) (10.9) (3.3) 76 173 99 251 61 (3.0) (6.8) (3.9) (9.9) (2.4) FUR3.D.x 32 (1 1/4) 76 51 (3.0) (2.0) 91 185 104 264 71 (3.6) (7.3) (4.1) (10.4) (2.8) 86 198 104 277 69 FUR3.E.x 40 (3.4) (7.8) (4.1) (10.9) (2.7) 76 51 (1 1/2) (3.0) (2.0) 102 185 117 282 81 (4.0) (7.3) (4.6) (11.1) (3.2) 102 185 117 282 81 FUR3.F.x 50 (4.0) (7.3) (4.6) (11.1) (3.2) 76 51 (2) (3.0) (2.0) 127 198 150 315 97 (5.0) (7.8) (5.9) (12.4) (3.8) FUR3.G.x 65 (2 1/2) 135 (5.3) 198 (7.8) 150 315 104 (5.9) (12.4) (4.1) 76 (3.0) 51 (2.0) FUR3.H.x 5 80 (3) 238 257 115 312 73 (9.4) (10.1) (4.5) (12.3) (2.9) 180 (7.1) 51 (2.0) Note 3: Note 4: Note 5: Weight does not include actuator. Kv is for straight through Kv (A to AB). Bypass Kv (B to AB) would be 70-80% of straight through Kv. Illustration valid for valve size DN15-65. DN80 has bypass port in Z plane. Weight 3 kg (lb) 0.73 (1.6) 0.73 (1.6) 0.73 (1.6) 1.0 (2.3) 1.6 (3.6) 1.5 (3.3) 1.6 (3.5) 1.6 (3.6) 2.4 (5.2) 2.4 (5.2) 3.9 (8.5) 4.1 (9.1) 10.4 (23.0) E Kv 4 m 3 /hr 0.29 0.51 0.87 2.1 3.7 6.9 0.35 0.57 1.1 2.1 3.3 6.1 9.5 0.35 0.56 1.1 2.0 3.0 8.7 7.4 3.9 13 19 27 3.5 7.5 17 11 23 29 3.5 7.2 12 28 20 53 21 33 49 71 94 33 64 86 65 87 108 130 151 173 Tech note · FlowCon Unimizer ® 3-way DN15-80 · january 2025 · www.flowcon.com H2 H1 L1 L2 H3 Page 3 of 8