SPECIFICATIONS FlowCon Actuators FlowCon Actuator 1 Supply voltage Type Power consumption Control signal Feedback Failsafe function Auxiliary switches Operation time Ambient temperature Humidity rating Protection Cable (supply) Weight T.0.2 24V AC / 30V DC Electrical, bi-directional motor 8VA Analog (0)2-10V DC or 4-20mA Analog (0)2-10V DC or 4-20mA Fail in place Optional as plug on module 85-90 sec -30°C to +50°C / -22°F to +122°F 5.95% rH, no condensation IP22 / NEMA2, indoor use only - upgradable to IP54 / NEMA3R Not included, recommended 0.75 mm 2 /AWG18 2.7 kg / 5.9 lb Note 1: FlowCon recommends actuators supplied by FlowCon International. T.0.3 120V AC / 240V AC Electrical, bi-directional motor 7VA Digital 2-position / 3-point floating No Fail in place Optional as plug on module 60-85 sec -30°C to +50°C / -22°F to +122°F 5.95% rH, no condensation IP22 / NEMA2, indoor use only - upgradable to IP54 / NEMA3R Not included, recommended 0.75 mm 2 /AWG18 2.3 kg / 5.0 lb T.0.4 24V AC / 30V DC Electrical, bi-directional motor 7VA Digital 2-position / 3-point floating No Fail in place Optional as plug on module 60-85 sec -30°C to +50°C / -22°F to +122°F 5.95% rH, no condensation IP22 / NEMA2, indoor use only - upgradable to IP54 / NEMA3R Not included, recommended 0.75 mm 2 /AWG18 2.0 kg / 4.4 lb DIMENSIONS AND WEIGHT (NOMINAL) Model no. Valve size L1 L2 2 H1 (max. length) mm mm mm mm (in) (in) (in) (in) F3UR.J.x 100 (4) 279 338 229 (11.0) (13.3) (9.0) F3UR.K.x 125 (5) 315 (12.4) 363 (14.3) 254 (10.0) H2 mm (in) 478 (18.8) D (depth, not shown) mm (in) Weight 3 kg (lb) 229 29.5 (9.0) (65) 483 254 34.0 (19.0) (10.0) (75) F3UR.L.x 150 (6) 353 (13.9) 384 (15.1) 279 (11.0) 505 (19.9) 279 (11.0) 40.8 (90) Note 2: L2 is maximum length, which is measured to end flange or mounting plate, whichever extends further. Note 3: Weight does not include actuator. Kv m 3 /hr 79 102 132 170 220 125 160 208 267 346 180 232 299 382 499 562 H2 H1 L1 L2 Tech note · FlowCon Unimizer ® 2-way DN100-150 · january 2025 · www.flowcon.com Page 2 of 6
FLANGE MATCH Model no. F3UR.J.x F3UR.K.x F3UR.L.x Flange size (“) 4 5 6 ASME B16.1 Class 125 ASME B16.5 Class 150 Flange size (mm) 100 125 150 PN10 EN 1092-1 PN16 PN25 PN40 MODEL NUMBER SELECTION Valve size: J = DN100 / 4” K = DN125 / 5” L = DN150 / 6” F3UR . . .L .S .1 . . Kv ID-number: 1 , 2 , 3 , 4 , 5 or 6 (see flow rate table page 5) Actuator 1 = FlowCon (standard) Type of actuator: 00 = no actuator Gear 24V modulating 70 = T.0.2 120V / 240V digital 20 = T.0.3 24V digital 10 = T.0.4 ID tag 0 = T = no ID tag (standard) hanging ID tag Example: F3UR.J.3.L.S.1.10.0 = FlowCon Unimizer ® 2-way, DN100 (4”) with Kv=132 m 3 /hr and FlowCon 24V digital actuator, without hanging ID tags. Note: If auxiliary switches are required, order the plug on auxiliary switch module, T-Aux , seperately. Tech note · FlowCon Unimizer ® 2-way DN100-150 · january 2025 · www.flowcon.com Page 3 of 6