SPECIFICATIONS FlowCon EV Actuators (Thermal): FlowCon Actuator 2 Supply voltage Type Power consumption Control signal Failsafe function End switch Operation time 4 Ambient temperature EV.0.2 24V AC -10%/+20%, 50/60Hz Thermal 1.0 watt 0-10V DC Normally closed 6 No Approx. 2.5 min 0ºC to +60ºC / +32°F to +140°F EV.0.3 230V AC ±10%, 50/60 Hz Thermal 1.0 watt ON/OFF Normally closed 6 No Approx. 4 min 0ºC to +60ºC / +32°F to +140°F EVP.0.3 3 230V AC ±10%, 50/60Hz Thermal 2.0 watt ON/OFF Normally closed 6 No Approx. 3 min 0ºC to +60ºC / +32°F to +140°F EV.0.4 24V AC/DC -10%/+20%, 50/60Hz Thermal 1.0 watt ON/OFF Normally closed 6 No Approx. 4 min 0ºC to +60ºC / +32°F to +140°F Protection Cable Weight 5 IP54 including upside-down, class III Plug-in, 3 x 0.22 mm 2 , 1 m PVC 3 x AWG24, 3.3 ft PVC 0.12 kg / 0.26 lb IP54 including upside-down, class II Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG18, 3.3 ft PVC 0.11 kg / 0.24 lb IP54 including upside-down, class II Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG18, 3.3 ft PVC 0.11 kg / 0.24 lb IP54 including upside-down, class III Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG18, 3.3 ft PVC 0.11 kg / 0.24 lb FlowCon Actuator 2 EV.0.5 EV.1.3 EV.1.4 Supply voltage 120V AC ±10%, 50/60Hz 230V AC ±10%, 50/60 Hz 24V AC/DC -10%/+20%, 50/60 Hz Type Thermal Thermal Thermal Power consumption 1.0 watt 1.0 watt 1.0 watt Control signal Failsafe function ON/OFF Normally closed 6 ON/OFF Normally closed 6 ON/OFF Normally closed 6 End switch No Yes Yes Switching point - Approx. 2 mm / 0.08 in Approx. 2 mm / 0.08 in Switching capacity Operation time 4 - Approx. 4 min 230V AC, 5A ohm resistive load, 1A inductive load Approx. 4 min 24V AC, 3A ohm resistive load, 1A inductive load Approx. 4 min Ambient temperature 0ºC to +60ºC / +32°F to +140°F 0ºC to +60ºC / +32°F to +140°F 0ºC to +60ºC / +32°F to +140°F Protection IP54 including upside-down, class II IP54 including upside-down, class II IP54 including upside-down class III Cable Weight 5 Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG18, 3.3 ft PVC 0.11 kg / 0.24 lb Fixed, 4 x 0.75 mm 2 ,1 m PVC 4 x AWG18, 3.3 ft PVC 0.16 kg / 0.35 lb Fixed, 4 x 0.75 mm 2 ,1 m PVC 4 x AWG18, 3.3 ft PVC 0.16 kg / 0.35 lb Note 2: Note 3: Note 4: Note 5: Note 6: FlowCon warranty is voided using other actuators than supplied or recommended by FlowCon International. For FlowCon Essentia medium flow and high flow, use factor 0.9 on flow table data to get obtainable flow with EVP.0.3 actuator. Closing time is approximately the double dependent on ambient temperature. Weight includes actuator, adaptor ring and 1 meter cable. To ensure that the valve is in an open position during commission of the system, the actuator will be delivered in a normal open position and remain in this position until it is electrically operated first time. FlowCon EV.0.2 FlowCon EV.0.3 / 0.4 / 0.5 FlowCon EV.1.3 / 1.4 FlowCon EVP.0.3 Tech note · FlowCon Essentia · august 2025 · www.flowcon.com Page 2 of 10
Download PDF file