ACCESSORIES • ACC00210: Capillary tube with fittings and adaptor for connection to FlowCon standard housing taps. • ACC0001: Adjustment key. • ACC0086: Protection cap. HOW TO SELECT The FlowCon ADP valve is to be selected based on the required flow rate and calculated differential pressure across the controlled circuit ( Δ pC) at design flow (see flow rate table and flow curves below for reference). Δp H Δ pC Δ pBV Controlled Circuit EXAMPLE: Design flow rate = 340 l/hr (1.50 GPM) Pipe size = DN15 (1/2”) Δ pC = 7 kPaD (1.02 psid) (design condition)  Select valves (DPCV and partner valve) based on line size and system requirements to eliminate pipe modifications. In this example it will be FlowCon ADP.0 and FlowCon Partner Ball. Δ pV Δ pC = Controlled Δ p Circuit Δ pV = Δ p across FlowCon ADP Δ pBV = Δ p across Partner Valve Δ pH = Δ p Pump Head  Select FlowCon ADP setting based on required (calculated) Δ pC at design flow. From the ADP.0 flow rate table, proper setting is found in the intersection between needed Δ pC and design flow. To optimize the system energy efficiency, select the setting providing closest higher Δ pC. In this case setting 3.0 will be the proper choice. ADP.0 will with this setting allow 340 l/hr (1.50 GPM) at the design Δ pC.  Select your partner valve (FlowCon Partner Ball is recommended) and determine the Δ pBV: In this case recommendations are followed, and a FlowCon Partner Ball is selected. From its specification Δ pBV is calculated to 1.11 kPaD (0.16 pisd).  Determine minimum pump head: Note that ΔpV MIN + ΔpC is always 17 kPaD for an ADP.0 + calculated Δp of the DPCV housing. Δp is calculated using the standard formula Δp = (Qdesign / Kv) 2 * 100. In this case Δp = (0.34 m 3 /hr / 3.1 m 3 /hr) 2 * 100 = 1.2 kPaD (0.17 pisd) ΔpH = ΔpBV + (ΔpC + ΔpV MIN ) + Δp = 1.11 + 17 + 1.2 = 19.31 kPaD (2.8 psid) The pump can now be selected considering a pressure drop of 20 kPaD (2.9 psid).  FlowCon ADP.0 in setting 3.0 will hereafter ensure that design flow never exceeds 340 l/hr (1.50 GPM) at the design Δ pC. Applying a thermal actuator on the FlowCon ADP will allow design Δ pC and flow when open and a full shut-off function when the actuator is closed. Tech note · FlowCon ADP · february 2024 · www.flowcon.com Page 6 of 8

Page number 7

FLOW RATE AND SETTINGS S S et e ti t n t g i s ngs 5.0 4.5 4.0 3.5 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 3 4 6 FlowCon ADP.0 Flo Fl w ow ( ( l l / / h hr ) ) 700 600 500 400 300 200 100 0 8 10 12 14 16 17 D Δ p p C C ( ( k k P P aD a ) ) S S et e ti t n t g i s ngs 5.0 4.5 4.0 3.5 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 FlowCon ADP.1 Flo Fl w ow ( ( l l / / h hr ) ) 1200 1000 800 600 400 200 35 0 10 15 20 25 30 35 D Δ p p C C ( ( k k P P aD a ) ) Tech note · FlowCon ADP · february 2024 · www.flowcon.com Page 7 of 8

    ...