Page number 2
SPECIFICATIONS FlowCon T.0.3 Supply voltage: Type: Power consumption: Impulse voltage: Control signal: Feedback: Failsafe function: Auxiliary switches: Auxiliary switch rating: Auxiliary switch impulse Manual override: Position indicator: Operation time: Actuating force: Angle of rotation: Direction of rotation: Ambient temperature: Humidity rating: Protection: voltage: CE conformity: Cable: 110-130V AC/220-250V AC, 50/60 Hz (optional via high voltage selector) Electrical, bi-directional motor 7VA 330V Digital 3-point floating or 2-position No Fail in place Optional (as plug on module) 3A resistive, 250V AC 4000V Yes (do not press clutch, when actuator is powered) Yes 60-85 sec torque dependent 20 Nm at rated voltage 0 to 90°, mechanically adjustable Clockwise (CW) (optional counter clockwise (CCW) via DIP switch) -30°C to +50°C (-22°F to +122°F) 5.95% rH, no condensation Standard: IP22 (NEMA 2), indoor use only Optional watertight bushings: IP54 (NEMA 3R), indoor use only Yes Not included; recommendation 0.75 mm 2 / AWG18 FlowCon T.0.4 Supply voltage: Type: Power consumption: Impulse voltage: Control signal: Feedback: Failsafe function: Auxiliary switches: Auxiliary switch rating: Auxiliary switch impulse Manual override: Position indicator: Operation time: Actuating force: Angle of rotation: Direction of rotation: Ambient temperature: Humidity rating: Protection: voltage: CE conformity: Cable: 22-26V AC, 50/60 Hz or 28-32V DC Electrical, bi-directional motor 7VA 330V Digital 3-point floating or 2-position No Fail in place Optional (as plug on module) 3A resistive, 250V AC 4000V Yes (do not press clutch, when actuator is powered) Yes 60-85 sec torque dependent 20 Nm at rated voltage 0 to 90°, mechanically adjustable Clockwise (CW) (optional counter clockwise (CCW) via DIP switch) -30°C to +50°C (-22°F to +122°F) 5.95% rH, no condensation Standard: IP22 (NEMA 2), indoor use only Optional watertight bushings: IP54 (NEMA 3R), indoor use only Yes Not included; recommendation 0.75 mm 2 / AWG18 Tech note · FlowCon T actuators · january 2025 · www.flowcon.com Page 2 of 5
Page number 3
DIMENSIONS AND WEIGHT (NOMINAL) Actuator T.0.2 T.0.3 T.0.4 L1 mm (in) 232 (9.13) L2 D H Weight (depth) mm (in) mm (in) mm (in) kgs. (lb) H 2.7 (5.9) 33.8 132 90.2 2.3 (1.33) (5.20) (3.55) (5.0) 2.0 (4.4) L2 L1 FlowCon T Actuator Actuator with plug on L D H Weight T-Aux. module (depth) T.0.2 + T-Aux T.0.3 + T-Aux T.0.4 + T-Aux mm mm mm kgs. (in) (in) (in) (lb) H 3.08 (6.8) 272 135 110 2.68 (10.7) (5.3) (4.3) (5.9) 2.38 (5.2) L FlowCon T Actuator with T-Aux MODEL NUMBER SELECTION Supply and control signal: 2 = 24V, modulating 3 = 120V/240V, digital 4 = 24V, digital Example: T.0.4 = FlowCon T electrical actuator 24V 3-point floating or 2-postion. ACCESSORIES • 1C50007: • T-Aux: Watertight bushing Plug on auxiliary switch module T.0. Tech note · FlowCon T actuators · january 2025 · www.flowcon.com Page 3 of 5