SPECIFICATIONS Valve Material: • Housing: • Ball valve: • End connection: • P/t plugs: End connections 2 : Housing taps: Note 2: NPT only available ex. US-factory. A, DN15-25 / 1/2”-1”: DZR brass ASTM CuZn36Pb2As AB, DN15-25 / 1/2”-1”: DZR brass ASTM CuZn36Pb2As ABV, DN15-25 / 1/2”-1”: Brass ASTM CuZn40Pb2 ABV: Chemically nickel-plated brass ASTM CuZn40Pb2 ABV: Brass alloy AB/ABV: DZR brass ASTM CuZn36Pb2As with PTFE seal A/AB: Fixed female ISO or NPT ABV: Double union end connection ISO or NPT AB/ABV: 1/4” ISO FlowCon actuators FlowCon Actuator 3 Supply voltage Type Power consumption Control signal Failsafe function 4 End switch Operation time 5 Ambient temperature Protection Cable Weight 6 EV.0.2 24V AC -10%/+20%, 50/60Hz Thermal 1.0 watt 0-10V DC Normally closed No Approx. 2.5 min 0ºC to +60ºC / +32°F to +140°F IP54 including upside-down, class III Plug-in, 3 x 0.20 mm 2 , 1 m PVC 3 x AWG24, 3.3 ft PVC 0.12 kg / 0.26 lb EV.0.3 230V AC ±10%, 50/60 Hz Thermal 1.0 watt ON/OFF Normally closed No Approx. 4 min 0ºC to +60ºC / +32°F to +140°F IP54 including upside-down, class II Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG20, 3.3 ft PVC 0.11 kg / 0.24 lb EVP.0.3 230V AC ±10%, 50/60Hz Thermal 2.0 watt ON/OFF Normally closed No Approx. 3 min 0ºC to +60ºC / +32°F to +140°F IP54 including upside-down, class II Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG20, 3.3 ft PVC 0.11 kg / 0.24 lb EV.0.4 24V AC/DC -10%/+20%, 50/60Hz Thermal 1.0 watt ON/OFF Normally closed No Approx. 4 min 0ºC to +60ºC / +32°F to +140°F IP54 including upside-down, class III Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG20, 3.3 ft PVC 0.11 kg / 0.24 lb FlowCon Actuator 3 Supply voltage EV.0.5 120V AC ±10%, 50/60Hz EV.1.3 230V AC ±10%, 50/60 Hz EV.1.4 24V AC/DC -10%/+20%, 50/60 Hz Type Thermal Thermal Thermal Power consumption 1.0 watt 1.0 watt 1.0 watt Control signal Failsafe function 4 ON/OFF Normally closed ON/OFF Normally closed ON/OFF Normally closed End switch No Yes Yes Switching point - App. 2 mm / 0.08 in App. 2 mm / 0.08 in Switching capacity Operation time 5 - Approx. 4 min 230V AC, 5A ohm resistive load, 1A inductive load Approx. 4 min 24V AC, 3A ohm resistive load, 1A inductive load Approx. 4 min Ambient temperature 0ºC to +60ºC / +32°F to +140°F 0ºC to +60ºC / +32°F to +140°F 0ºC to +60ºC / +32°F to +140°F Protection IP54 including upside-down, class II IP54 including upside-down, class II IP54 including upside-down class III Cable Weight 6 Fixed, 2 x 0.75 mm 2 , 1 m PVC 2 x AWG20, 3.3 ft PVC 0.11 kg / 0.24 lb Fixed, 4 x 0.75 mm 2 ,1 m PVC 4 x AWG20, 3.3 ft PVC 0.16 kg / 0.35 lb Fixed, 4 x 0.75 mm 2 ,1 m PVC 4 x AWG20, 3.3 ft PVC 0.16 kg / 0.35 lb Note 3: Note 4: Note 5: Note 6: FlowCon warranty is voided using other actuators than supplied or recommended by FlowCon International. To ensure that the valve is in an open position during commission of the system, the actuator will be delivered in a normal open position and remain in this position until it is electrically operated first time. Closing time is approximately the double dependent on ambient temperature. Weight includes actuator, adaptor ring and 1 meter cable. FlowCon EV.0.2 valve adaptor, black FlowCon EV.0.3 / 0.4 / 0.5 valve adaptor, black Tech note · FlowCon EVS · may 2025 · www.flowcon.com FlowCon EV.1.3 / 1.4 valve adaptor, black FlowCon EVP.0.3 valve adaptor, black Page 2 of 7
Download PDF file