DIMENSIONS AND WEIGHT (NOMINAL) Valve model Valve size Insert L H1 size mm mm (in) (in) 15 (1/2) A 20 20 (3/4) (3/4) 25 (1) 15 (1/2) 20 20 (3/4) (3/4) 25 (1) AB (215) 40 32 (1 1/2) (1 1/4) 40 (1 1/2) 50 50 (2) (2) 15 (1/2) 20 20 (3/4) (3/4) 25 (1) ABV 25 (1) 32 (1 1/4) 40 (1 1/2) 40 (1 1/2) Note 2: Add end connection length to housing length Note 3: Weight does not include end connections Note 4: Weight is valid for brass housing only. mm (in) 80 (3.15) 91 (3.58) 81 (3.19) 85 (3.35) 102 (4.02) 128 (5.04) 169 (6.65) 122 (4.80) 162 (6.38) mm (in) 31 (1.22) 31 (1.22) 47 (1.85) 55 (2.17) 33 (1.30) 42 (1.65) H2 mm (in) 80 (3.15) 78 (3.07) 99 (3.90) 117 (4.61) 78 (3.07) 99 (3.90) End connections C 2 Female ISO (NPT) Male ISO (NPT) Sweat ISO - - - - - - - - - 22 (0.87) 24 (0.95) 20 22 (0.87) 25 (0.99) 20 - 39 (1.54) 22 35 (1.38) 40 (1.57) 34 33 (1.30) 40 (1.57) 34 33 (1.30) 42 (1.65) - Weight 3 kg (lb) 0.48 (1.06) 0.42 (0.93) 0.57 (1.26) 0.47 (1.04) 0.48 (1.06) 0.66 (1.46) 1.80 (4.00) 1.64 (3.61) 3.85 4 (8.49) 4 3.45 4 (7.61) 4 0.87 (1.92) 2.08 (4.59) H2 H1 L FlowCon E-JUST.1.X.X in FlowCon A valve DN15/20/25 (1/2", 3/4", 1") H2 H1 L C FlowCon E-JUST.1.X.X in FlowCon ABV.1 valve DN15/20/25 (1/2", 3/4", 1") H2 H1 L FlowCon E-JUST.2.Y.G in FlowCon AB valve DN25/32 (1", 1 1/4") Tech note · FlowCon E-JUST · february 2024 · www.flowcon.com Page 2 of 8
MODEL NUMBER SELECTION Type of housing: 20 mm / 3/4" E-JUST A.15 = A, DN15 / 1/2" A.20 = A, DN20 / 3/4" A.25 = A, DN25 / 1" AB.15 = AB, DN15 / 1/2" AB.20 = AB, DN20 / 3/4" AB.25K = AB, DN25 / 1" ABV.1 = ABV, DN15-25 / 1/2"-1" 40 mm / 1 1/2" E-JUST AB.25 = AB, DN25 / 1" AB.32 = AB, DN32 / 1 1/4" ABV.2 = ABV, DN25-40 / 1"-1 1/2" 50 mm / 2" E-JUST AB.40 = AB, DN40 / 1 1/2" AB.50 = AB, DN50 / 2" . . . . . . . P/t plug requirements: 0 = no (p/t) plugs B = pressure/temperature plugs P = taps plugged Union end connections (inlet x outlet): 0.0 = no union ends Model and size Female threaded ABV.1 with E = 15 mm / 1/2” E-JUST, 20 mm F = 20 mm / 3/4” ABV.2 with E-JUST, 40 mm G = 25 mm / 1” P = 32 mm / 1 1/4” Q = 40 mm / 1 1/2” Male threaded H = 15 mm / 1/2” I = 20 mm / 3/4” J = 25 mm / 1” J = 25 mm / 1” S = 32 mm / 1 1/4” T = 40 mm / 1 1/2” Sweat K = 15 mm L = 18 mm M = 22 mm N = 28 mm W = 35 mm Connection standard and material: I = ISO (Standard) DI = Ductile iron ISO (only AB40 and AB50) N = NPT Pressure range: 0 = no insert Y = 17-200 kPaD, 2.5-29 psid (20 mm / 3/4” E-JUST red w. white pawl) 17-210 kPaD, 2.5-30 psid (20 mm / 3/4” E-JUST black or green w. white pawl) 17-400 kPaD, 2.5-58 psid (40 mm / 1 1/2” E-JUST) G = 20-400 kPaD, 2.9-58 psid (50 mm / 2” E-JUST) 30-400 kPaD, 4.4-58 psid (20 mm / 3/4” E-JUST red w. grey pawl) 35-400 kPaD, 5.1-58 psid (20 mm / 3/4” E-JUST black or green w. grey pawl) Color code: 0 = no insert B = black G = green R = red Setting: 0.0 = E.4-2 = no insert standard 4.2 Example: AB.15.B.0.0.I.Y.R.E.4-2 = DN15 (1/2”) AB housing with p/t plugs and FlowCon red E-JUST, 17-200 kPaD (2.5-29 psid), setting 4.2. Tech note · FlowCon E-JUST · february 2024 · www.flowcon.com Page 3 of 8