Page number 2
DIMENSIONS AND WEIGHT (NOMINAL) Model Valve size Insert L H1 no. size (±1%) mm mm mm mm (in) (in) (in) (in) F325X 50 (2) 174 (6.85) 53.5 (2.11) F326X 65 (2 1/2) 80 (3) 174 (6.85) 58.5 (2.30) F332X 100 (4) 197 (7.76) 86.0 (3.39) F334X 150 (6) 184 (7.24) 110 (4.33) F337X 200 (8) 184 (7.24) 138 (5.43) F368X 250 (10) 203 (8.00) 171 (6.73) F369X 300 (12) 203 (8.00) 203 (7.99) F339X 350 (14) 80 203 224 (3) (8.00) (8.82) F384X 400 (16) 241 (9.49) 256 (10.1) F385X 450 3 (18) 3 241 (9.49) 273 (10.7) F338X 500 3 (20) 3 279 (11.0) 304 (12.0) F386X 600 3 (24) 3 279 (11.0) 357 (14.1) F330X 800 3 (30) 3 800 3 (32) 3 432 (17.0) 442 (17.4) F370X 900 3 (36) 3 432 (17.0) 515 (20.3) F395X 1000 3 (40) 3 438 (17.2) 570 (22.4) Note 1: Nominal weight, including inserts and p/t plugs, exact weight is dependent on inserts. Note 2: Hi-flow inserts do not fit in this wafer size. Note 3: 450 mm (18”) and larger supplied with eyebolt for lifting. H2 mm (in) 144 (5.67) 149 (5.87) 176 (6.93) 200 (7.87) 228 (8.98) 261 (10.3) 293 (11.5) 314 (12.4) 346 (13.6) 363 (14.3) 394 (15.5) 447 (17.6) 532 (20.9) 605 (23.8) 660 (26.0) D (flange) mm (in) 165 (6.5) 185 (7) 200 (7.5) 235 (9) 285 (11) 360 (13.5) 425 (17.5) 515 (19) 555 (21) 620 (23.5) 640 (25) 715 (30.5) 840 (36) 1015 (43) 1015 (41.75) 1185 (46) 1320 (53) Weight 1 kgs. (lb) 4.15 (9.15) 6.65 (14.7) 15.7 (34.6) 19.7 (43.4) 26.7 (58.9) 36.7 (80.9) 61.7 (136) 69.7 (154) 103 (227) 115 (254) 164 (362) 218 (481) 402 (886) 706 (1560) 841 (1850) Max no. of inserts per wafer 1 2 1 2 2 2 4 7 11 15 19 24 31 37 55 85 97 121 H2 P1 DN200 P1 DN200 H1 D L Tech note · FlowCon Wafer · february 2024 · www.flowcon.com Page 2 of 7
Page number 3
MODEL NUMBER SELECTION Housing type: 25 = DN50 / 2” 26 = DN65/80 / 2 1/2” / 3” 32 = DN100 / 4” 34 = DN150 / 6” 37 = DN200 / 8” 68 = DN250 / 10” 69 = DN300 / 12” 39 = DN350 / 14” 84 = DN400 / 16” 85 = DN450 / 18” 38 = DN500 / 20” 86 = DN600 / 24” 30 = DN800 / 30”/32” 70 = DN900 / 36” 95 = DN1000 / 40” Pressure 0 = 1 = 2 = 4 = 8 = 3 = 5 = 6 = range: None Standard / Hi-Capacity: 10-135 kPaD (1.5-20 psid) and 22-210 kPaD (3.2-30 psid) and 40-390 kPaD (5.8-57 psid) 90-880 kPaD (13-128 psid) Hi-Flow 4 : 20-125 kPaD (2.9-18 psid) 35-220 kPaD (5.1-32 psid) 55-220 kPaD (8.0-32 psid) 28-135 55-210 kPaD kPaD (4.0-20 (8.0-30 psid) psid) P/t plug requirements: B = pressure/temperature plugs (standard) F3 . . .B Example: F3.37.0.B =Wafer for 200 mm (8”) flanges with p/t plugs and no inserts. Note: Please specify flow requirements as per selection chart when ordering with insert(s). Note 4: Not possible for DN50-100 (2”-4”). Tech note · FlowCon Wafer · february 2024 · www.flowcon.com Page 3 of 7