Page number 2

SPECIFICATIONS (.continued) FlowCon Actuators available for FlowCon ADP FlowCon Actuator 1 FT.0.3 FT.0.4 Supply voltage Type Power consumption Control signal Failsafe function Operation time 2 Ambient temperature 3 Protection Cable Weight 230V AC ±10%, 50/60Hz Thermal 1.2W ON/OFF, Normally closed Yes App. 4.5 minutes +1 ° C to +50 ° C IP54 including upside-down, class II Fixed, 1 meter 0.11 kg 24V AC/DC -10%. +20%, 50/60Hz Thermal 1.2W ON/OFF, Normally closed Yes App. 4.5 minutes +1 ° C to +50 ° C IP54 including upside-down, class III Fixed, 1 meter 0.11 kg Note 2: FlowCon warranty is voided using other actuators than supplied by FlowCon International. Note 3: Closing time is approximately the double dependent on ambient temperature. Note 4: Stated temperature rating is defined due to no external insert condensation. FT.0.3 A 20625-00 230 V NC 1,2 W 1403 Made in Germany FlowCon FT.0.3/0.4 DIMENSIONS AND WEIGHT (NOMINAL) Model Valve Valve size Insert L H no. model size mm mm mm mm (in) (in) (in) (in) ADP.X.04 ADP.X.05 A 15 (1/2) 80 20 20 (3.2) 31 (3/4) (3/4) (1.2) ADP.X.06 25 (1) 91 (3.6) ADP.X.01 15 (1/2) 81 (3.2) ADP.X.02 AB 20 20 85 31 (3/4) (3/4) (3.3) (1.2) ADP.X.07 25 (1) 102 (4.0) 15 (1/2) ADP.X.03 ABV 20 (3/4) 20 (3/4) 122 (4.8) 33 (1.3) 25 (1) Note 5: Add end connection length to body length. Note 6: Weight does not include end connections or actuator. Note 7: For FlowCon ADP insert and valve body combined. H1 H2 H3 End connections C 5 Weight 6 Kvs/Cvs 7 with cap with actuator Female Male Sweat mm mm mm ISO ISO ISO kgs. m 3 /hr (in) (in) (in) (NPT) (NPT) (lb) (GPM) 0.68 (1.50) 72 78 125 (2.8) (3.1) (4.9) - - - 0.64 3.7 (1.41) (4.3) 0.73 (1.61) 0.64 (1.41) 72 78 125 (2.8) (3.1) (4.9) - - - 0.66 3.7 (1.46) (4.3) 0.86 (1.90) 22 (0.87) 24 (0.95) 20 72 (2.8) 78 (3.1) 125 22 25 (4.9) (0.87) (0.99) 20 1.03 3.7 (2.27) (4.3) - 39 (1.54) 22 H1 H L FlowCon ADP.0/1 in FlowCon AB DN15/20/25 (1/2”, 3/4”, 1”) H2 H L FlowCon ADP.0/1 in FlowCon AB DN15/20/25 (1/2”, 3/4”, 1”) and with FlowCon Protection Cap H3 H L FlowCon ADP.0/1 in FlowCon AB DN15/20/25 (1/2”, 3/4”, 1”) and with FlowCon FT actuator Tech note · FlowCon ADP · february 2024 · www.flowcon.com Page 2 of 8

Page number 3

MODEL NUMBER SELECTION Pressure range: 0 = Low pressure 1 = High pressure ADP . . . . . . .2. Type of housing: 01 = AB DN15, 1/2” 02 = AB DN20, 3/4” 03 = ABV.1 DN15-25, 1/2”-1” 04 = A DN15, 1/2” 05 = A DN20, 3/4” 06 = A DN25, 1” 07 = AB DN25, 1” Type of actuator: 00 = No actuator 23 = FT.0.3 24 = FT.0.4 P/t plug requirements: 0 = no (p/t) plugs B = pressure/temperature plugs P = taps plugged Union end connections (inlet x outlet): 0.0 = no union ends Model and size Female threaded ABV.1 with ADP insert, 20 mm E = 15 mm / 1/2” F = 20 mm / 3/4” Male threaded H = 15 mm / 1/2” I = 20 mm / 3/4” J = 25 mm / 1” Sweat K = 15 mm L = 18 mm M = 22 mm Capillary tube connection: 2 = Capillary tube with union 1/4” to M8 adaptor FlowCon Partner Ball Connection standard: I = ISO N = NPT Example: ADP.0.01.00.B.0.0.2.I = FlowCon ADP, low pressure, in FlowCon AB housing (DN15 / 1/2”) ISO threaded with p/t plugs, no actuator but including capillary tube for connection to FlowCon Partner Ball. Tech note · FlowCon ADP · february 2024 · www.flowcon.com Page 3 of 8

    ...