Page number 2

SPECIFICATIONS Thermal actuator: FlowCon EV.0.3.R 1 , FlowCon EV.0.4.R 1 Supply voltage: Control signal: Power consumption: Operation time: Ambient temperature: Protection: Cable: Weight: EV.0.3.R: 230V AC, ±10% EV.0.4.R: 24V AC/DC, -10/+20% ON/OFF, normally closed 2 1.0 Watt Approx. 4 min 3 0°C to +60°C EV.0.3.R: IP54 including upside-down, class II EV.0.4.R: IP54 including upside-down, class III Fixed cable, 1 m / 3 ft 0.108 kg / 0.24 lb Type EV.0.3.R, EV.0.4.R Valve adaptor, red Note 1: Note 2: Note 3: FlowCon warranty is voided using other actuators than supplied or recommended by FlowCon International ApS. To ensure that the valve is in an open position during commission of the system, the actuator will be delivered in a normal open position and remain in this position until it is electrically operated first time. Closing time is approximately the double dependent on ambient temperature. Tech note · FlowCon T-JUST · november 2024 · www.flowcon.com Page 2 of 6

Page number 3

DIMENSIONS AND WEIGHT (NOMINAL) FlowCon T-JUST with FlowCon A-housing Valve size Valve Insert L H material size mm mm (in) (in) 15 Forged (1/2) brass 20 Forged (3/4) brass 20 20 Stainless (3/4) (3/4) Steel 25 Forged (1) brass mm (in) 80 (3.15) 91 (3.58) mm (in) 31 (1.22) H1 H2 (with actuator - not shown) mm mm (in) (in) 97 (3.82) 130 (5.12) Weight kg (lb) 0.59 (1.30) 0.52 (1.15) 0.61 (1.34) 0.69 (1.52) 15/D2N 0 H1 H L FlowCon T-JUST with FlowCon AB-housing 15 DN DN 15 Valve size mm (in) 15 (1/2) 20 (3/4) 25 (1) Insert size mm (in) 20 (3/4) L mm (in) 81 (3.19) 85 (3.35) 102 (4.02) H mm (in) 31 (1.22) H1 mm (in) 97 (3.82) H2 (with actuator - not shown) mm (in) 130 (5.12) Weight kg (lb) 0.60 (1.32) 0.63 (1.39) 0.78 (1.72) H1 H L FlowCon T-JUST with FlowCon ABV.1-housing Valve size Insert L size H H1 H2 End connections C 4 Weight 5 (with actuator - not shown) Female Male Sweat mm mm mm mm mm mm ISO ISO ISO kg H1 (in) (in) (in) (in) (in) (in) (NPT) (NPT) (lb) / 20 15 (1/2) 80 22 (0.87) 24 (0.95) 20 (3.15) 20 20 (3/4) (3/4) 33 97 (1.30) (3.82) 130 (5.12) 22 (0.87) 25 (0.99) 20 0.99 (2.18) H 25 91 (1) (3.58) Note 4: Add end connection length to housing length. Note 5: Weight does not include end connections. - 39 (1.54) 22 C L FlowCon T-JUST with FF-unit 6 Valve size Insert L size mm mm mm (in) (in) (in) 20 20 56 (3/4) (3/4) (2.20) Note 6: To be fitted as upgrading element. H mm (in) 32 (1.26) H1 mm (in) 97 (3.82) H2 (with actuator - not shown) mm (in) 130 (5.12) Weight kg (lb) 0.58 (1.28) H1 H L Tech note · FlowCon T-JUST · november 2024 · www.flowcon.com Page 3 of 6

    ...