Page number 4
FLANGE MATCH Model no. SM.3.X SM.4.X SM.5.X SM.6.2 Flange size (inch) 2 2 1/2 3 3 4 5 6 8 10 ASME B16.5 weld neck CIass 150 CIass 300 Flange size (mm) 50 65 80 80 100 125 150 200 250 PN10 EN1092-1 weld neck PN16 PN25 PN40 DESCRIPTION The SM series is a range of self-balancing dynamic flow control valves that are pressure independent and 2-way and ready to accept digital or analog input signals. Each valve has an adjustable maximum flow rate setting to enable flow limitation to and balancing of the coil or zone which the valve is controlling. All SM actuators are microprocessor based with a self-calibrating feature. The SM actuator range includes standard incl. feedback, failsafe and BACnet. All SM actuators are programmable and with display. The SM actuators accept analog 0(2)-10V DC or 0(4)-20mA as well as digital 3-point floating or 2-position input signals and work with selectable control mode of Linear flow, Equal percentage, Linear rotation or Linear signal. The larger range of SM-valves are all designed for double flange connection. They are available in four different valve body sizes. All shall have snap connection for fast mounting of actuator. Tech note · FlowCon SM DN50-250 / 2”-10” · april 2024 · www.flowcon.com Page 4 of 9
Page number 5
WIRING INSTRUCTION SM.0.0.0.3/4/6 Actuator 0(2)-10V modulating Black Blue White Green Input signal 0(2)-10V DC Feedback signal 0(2)-10V DC Power 24V AC/DC Ground/common SM.0.0.0.3/4/6 Actuator 2-position, Normally Closed Black Red White SM.0.0.0.6 Actuator RS-485 Serial BACnet A+ B- Signal ground SM.0.0.0.3/4/6 Actuator 2-position, Normally Open Black Blue White Red Green Black Blue White Red Green Close Open Feedback signal Power 24V AC/DC Ground/common SM.0.0.0.3/4/6 Actuator 3-point floating, Normally Closed Open Close Feedback signal Power 24V AC/DC Ground/common SM.0.0.0.3/4/6 Actuator 3-point floating, Normally Open Black Blue White Red Green Black Blue White Red Green Stop Open Close Feedback signal Power 24V AC/DC Ground/common Stop Close Open Feedback signal Power 24V AC/DC Ground/common Note: If feedback signal is not required, leave green wire detached. FLOW RATE TABLE Model no. Valve size mm inch Control range kPaD psid Lowest settable max flow l/sec l/hr GPM SM.3.0 50/65/80 2 / 2 1/2 / 3 30-800 4.4-116 1.48 5310 23.4 SM.3.1 50/65/80 2 / 2 1/2 / 3 30-800 4.4-116 2.57 9240 40.7 SM.3.2 50/65/80 2 / 2 1/2 / 3 35-800 5.1-116 3.55 12800 56.3 SM.4.1 80/100 3 / 4 30-800 4.4-116 3.49 12600 55.4 SM.4.2 80/100 3 / 4 35-800 5.1-116 4.73 17000 75.0 SM.4.3 80/100 3 / 4 50-800 7.3-116 3.68 13300 58.3 SM.5.1 125/150 5 / 6 30-800 4.4-116 6.48 23400 103 SM.5.2 125/150 5 / 6 35-800 5.1-116 7.10 25600 113 SM.6.2 200/250 8 / 10 35-800 5.1-116 9.21 33100 146 Accuracy: Greatest of either ±5% of controlled flow rate or ±2% of maximum flow rate. Turn down ratio lowest max flow 38:1 Highest settable max flow l/sec 4.16 7.15 9.89 9.38 14.2 20.2 23.3 29.5 76.8 l/hr 15000 25700 35600 33800 51000 72700 83800 106000 277000 GPM 65.9 113 157 149 225 320 369 468 1220 Turn down ratio highest max flow 228:1 Tech note · FlowCon SM DN50-250 / 2”-10” · april 2024 · www.flowcon.com Page 5 of 9