MODEL NUMBER SELECTION Δ pC defining SDP insert: 10 = 10 kPaD / 1.45 psid 20 = 20 kPaD / 2.90 psid 30 = 30 kPaD / 4.35 psid SDP . . . Type of housing: 01 = AB DN15, 1/2” 02 = AB DN20, 3/4” 03 = ABV.1 DN15-25, 1/2”-1” 04 = A DN15, 1/2” 05 = A DN20, 3/4” 06 = A DN25, 1” 07 = AB DN25, 1” P/t plug requirements: P = taps plugged B = p/t plugs - leave blank if A housing or no p/t plugs required Union end connections (inlet x outlet): Model and size Female threaded ABV.1 with SDP insert, 20 mm E = 15 mm / 1/2” F = 20 mm / 3/4” Male treaded H = 15 mm / 1/2” I = 20 mm / 3/4” J = 25 mm / 1” - leave blank if A- or AB housing or no end connections required Sweat K = 15 mm L = 18 mm M = 22 mm O = 1/2” R = 3/4” U = 1” Capillary tube connection - defined by partner valve connection size: 1 = Capillary tube for connection to QuickDisc® partner valve 2 = Capillary tube with union M8 to 1/4” adaptor according to ISO 7.1 (compatible with FlowCon p/t port drillings) Connection standard: I = ISO N = NPT . Example: SDP.10.03.B.EE.1.I =FlowCon SDP (10 kPaD / 1.45 psid) in FlowCon ABV.1 housing with p/t plugs and ISO female union end connections (DN15 / 1/2”) and with capillary tube for connection to QuickDisc® partner valve. Tech note · FlowCon SDP · june 2021 · www.flowcon.com Page 3 of 7