MODEL NUMBER SELECTION5 ABM . ______ . ______ . ______ . ______ . ______ . ______ . ______ . ______. ______ . ______ Insert body size: 1=ABM1 body (15/20/25mm) 2=ABM2 body (25/32/40mm) Insert Optimizer® insert: Insert 1, 2, 3, 4, 5 or 6 (Determine from dimension chart) Insert p/t plug requirement: 0=taps open B=pressure temperature plugs P=taps plugged Insert power supply: 0=if no actuator required 1=24V 2-position or 3-point-floating (BBTS1000) 2=240V 2-position or 3-point floating (without end switches) (BBTHV1200A) 3=24V modulating (BBMS2000) 4=24V 2-position or 3-point-floating, incl. auxiliary switches (BBTS1021) 5=240V 2-position or 3-point floating incl. auxiliary switches (BBTHV1221A) 6=24V modulating, incl. auxiliary switches (BBMS2021) 7=120V 2-position or 3-point-floating (without end switches) (BBTHV1100A) 8=120V 2-position or 3-point-floating, incl. auxiliary switches (BBTHV1121A) Insert inlet x outlet union end connections: Body size Union end 15-20mm, 1/2”-1” Female threaded E=15mm=1/2” F=20mm=3/4” G=25mm=1” P=32mm=1 1/4” Q=40mm=1 1/2” Male treaded H=15mm=1/2” I=20mm=3/4” J=25mm=1” J=25mm=1” S=32mm=1 1/4” T=40mm=1 1/2” Sweat K=15mm L=18mm M=22mm N=28mm W=35mm Union end 25-40mm, 1”-1 1/2” Insert connection standard: I=ISO N=NPT Insert a kPaD control range: 0 if no insert required Y= 15-130 kPaD (20mm standard composite insert) 17-200 kPaD (20mm E-JUST red - white pawl) 17-210 kPaD (20mm E-JUST black or green - white pawl) 17-400 kPaD (40mm E-JUST - white pawl) G= 30-400 kPaD (20mm standard composite insert) 30-400 kPaD (20mm E-JUST red - grey pawl) 35-400 kPaD (20mm E-JUST black or green - grey pawl) X= 15-130 kPaD (40mm standard composite insert) C= 22-300 kPaD (40mm standard composite insert) D= 30-410 kPaD (40mm standard composite insert) (Determine from insert selection chart) Insert automatic flow limiting insert code: 0 if no insert required Y=grey R=red U=blue (Determine from insert selection chart) B=black G=green W=white Insert insert dial setting/type: 1 to 8=dial setting on standard composite insert 0=standard pre-setting of 2 on standard composite insert E=E-JUST insert (Determine from insert selection chart) Example: ABM.1.1.B.1.E.E.I.Y.Y.0=ABM1-body with Optimizer® insert 1, p/t plugs and 24V actuator, 15mm ISO female threaded union connections and a Y-type grey standard composite insert - pre-setting 2. Note 5: Flow rate, color and dial setting of insert are indicated on label affixed to body. EQUAL PERCENTAGE CHARACTERISTIC The Flow Optimizer® provies equal percentage control so that the heat output at the coil is linear when compared to the open area of the ball. Equal percentage characteristic of a Control Valve with a ratio of 1:20 Percentage of the Kvs Percentage opening of the valve Tech note · FlowCon ABM 15-40mm · june 2016 · www.flowcon.com Page 3 of 13
Download PDF file