Page number 6
FlowCon SM DN15-250 (1/2”-10”) 11/2024 In Operation Display Description Unit scale indicator. Battery level indicator. Alarm indicator. Information Current flow rate 1 . Note 1: The flow rate shown on the actuator display is a calculated value. Flow rates below 1.0 valve rotation is shown as indications, illustrated with an apostrophe in front of the flow rate. If display shows “NA” the valve model has not been chosen in programming menu step 2. Values l/sec or l/min or GPM. mA or VDC. Basic version with no battery (SM.0.0.0.3) Failsafe version with battery (SM.0.0.0.4/6) Low battery level, charging needed. Medium battery level. High battery level, fully charged. Blinking if actuator is still functional (warning). Fully on if actuator is not working (critical). CONTROL SIGNAL 6.0 VDC FEEDBAC SIGNAL 6.0 VDC VALVE SM. 3.1 pressur range 30-800 kpad MAXIMUM FLOW RATE 6.580 L/SEC OPERAT DIRECT NC ACTUAT.MODE LIN flo FAIL SAFE DIRECT CLOSE ERROR CODE 01 MAC Address 000 device instanc 0497000 T1 50c T2 30c DT 20.0 DP100kp Use to go to next information line and to go to the previous. SM.0.0.0.3/4 SM.0.0.0.6 This paper is a supplement to the FlowCon General Instruction Latest release of any FlowCon material is available on www.flowcon.com Page 6 of 8
Page number 7
FlowCon SM DN15-250 (1/2”-10”) 11/2024 Alarm Menu ⚠ To enter the alarm menu, simultaneously press and for 6 seconds . The alarm menu is only accessible if an alarm is present (i.e. when the icon is displayed). Press to go to the next alarm display and press to go to previous. For fast menu exit press and simultaneously for 6 seconds. The actuator will automatically return to normal operation mode if no action is detected on arrow keys for 1 minute. ⚠ ⚠ If the actuator is still functioning (= warning code 02, 04, 05 with failsafe and 07 with failsafe), the icon will blink. If the actuator is NOT functioning (=error code 01, 03, 05 without failsafe, 06 and 08 with BACnet), the icon is fully on. Error codes will be shown in the information part of the actuator display. Display Description Alarm. Action Enter password. If enabled in programming menu step 11 Disabled by default. Password: 3569266. Code 01 02 03 04 05 06 07 08 ⚠ Icon FULL ON ⚠ BLINKING ⚠ FULL ON ⚠ BLINKING ⚠ FULL ON ⚠ BLINKING ⚠ FULL ON ⚠ BLINKING ⚠ FULL ON Description Valve/actuator is overtorqued. Actuator has reached its torque limit in the past. Critical - over temperature. High temperature. Details Operation is stopped. Actuator will retry operation every 4 minutes. If over torque condition disappear, error will convert to error code 02. Actuator is functioning. To reset the alarm simultaneously press and for 6 seconds. Critical: Temperature in actuator is at least 70ºC, motor operation is stopped. If temperature is decreasing, operation will resume. Actuator is still functioning. Temperature in actuator is at least 50ºC as limited according to tech note. If tempera- ture is decreasing, operation will resume. No Failsafe: Power supply not in range. With Failsafe: Power supply not de- tected / not in range. Control signal not detected. Battery error. BACnet fallback mode Operation is stopped. Alarm will automatically reset when voltage is back in range. Failsafe is activated. Alarm will automatically reset when voltage is back in range. Operation is stopped. Alarm will automatically reset when control signal is back in range. Battery is not properly connected. Alarm will reset when battery is properly connected. Only valid for SM.0.0.0.4/6 (failsafe models). BACnet control value has not been updated and BAC- net fallback timeout has been reached. Alarm will reset when BACnet control signal is refreshed. Only valid for SM.0.0.0.6 (BACnet model). This paper is a supplement to the FlowCon General Instruction Latest release of any FlowCon material is available on www.flowcon.com Page 7 of 8