Technical Data For further information please see FlowCon tech note and the catalogue: FlowCon Inserts. For latest updates please see www.flowcon.com K DN15 Static Pressure Temperature Rating (media) Pressure Drop Data Valve (Kv-value) (Cv-value) (m³/hr) (GPM) (kPa) (psi) (ºC) (ºF) K DN20 2500 360 -30 to +120 -22 to +248 K DN25 K DN25 K DN32 2500 360 -30 to +120 -22 to +248 K DN40 K DN40 230 -30 to +120 -22 to +248 K DN50 K DN50 K DN65 1600 230 -30 to +120 -22 to +248 K DN80 1600 NOTE: For pump head calculations, add the minimum pressure differential for the index circuit to the other components pressure losses (i.e. valves, coil, etc.) 5 5.8 7 8.1 F360xxx (mm) (inch) (kPaD) (psid) (l/sec) (GPM) 20mm 3/4” 10-880 1-128 0.021-1.01 0.333-16.0 10 11.6 20 23.2 30 34.8 F361xxx 40mm 1 1/2” 10-880 1-128 0.189-2.78 3.00-44.0 35 40.6 52 60.3 65 75.4 F324xxxx 80mm 3” 10-880 1-128 0.883-10.10 14.0-160 Stainless Steel Insert Size of Insert Pressure Differential Flow Rate F3C2xxxx 50mm 2” 10-880 1-128 0.757-7.19 12.0-114 www.flowcon.com D E N M A R K • D U B A I • U S A • S I N G A P O R E FlowCon International can accept no responsibility for possible errors in any printed material. All rights reserved. February 2016