<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>HUBER+SUHNER   Low Frequency</title><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/RSS.ashx</link><description>HUBER+SUHNER   Low Frequency Pages</description><lastBuildDate>Tue, 14 Aug 2012 13:42:14 +0200</lastBuildDate><a10:id>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/</a10:id><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=1</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=1</link><title>HUBER+SUHNER   Low Frequency Page 1</title><description>for industrial applications Wires and cables edition 2010</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=2</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=2</link><title>HUBER+SUHNER   Low Frequency Page 2</title><description>2 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=3</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=3</link><title>HUBER+SUHNER   Low Frequency Page 3</title><description>Wires and cables for industrial applications – table of content Introduction Short description of the application fields 3 RADOX ® 125, RADOX ® 155, KDJ-11 Flexible single cores, cables and wires 21 RADOX ® UL/CSA Flexible single cores, multi core cables and wires UL recognised 51 RADOX ® System Cables Single cores, single core cables multi core cables and wires 71 RADOX ® SOLAR Single core and multi core cables 107 RADOX ® FR Safety cables with circuit integrity in case of fire 119 General technical information 133 HUBER+SUHNER Excellence in Connectivity Solutions 3 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=4</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=4</link><title>HUBER+SUHNER   Low Frequency Page 4</title><description>4 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=5</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=5</link><title>HUBER+SUHNER   Low Frequency Page 5</title><description>RADOX® by HUBER+SUHNER – for the toughest conditions RADOX®, the registered HUBER+SUHNER trademark, is synonymous with high-grade WIRE+CABLE products developed and produced in-house. RADOX® insulating and jacketing material, which are predominantly electron-beam cross-linked, possess the special properties required for developing and manufacturing technically superior products. We can also provide customer specific solutions. All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS). HUBER+SUHNER 5 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=6</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=6</link><title>HUBER+SUHNER   Low Frequency Page 6</title><description>Photo Adtranz 6 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=7</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=7</link><title>HUBER+SUHNER   Low Frequency Page 7</title><description>Single core/multi core cables for power and signal transmission in industrial applications Electronic control systems automatically control processes, transmit data and govern motions such as swivelling and conveying etc. The reliability and uptime of such highly automated, complex technical systems is necessary to ensure the efficiency of state-of-the-art production processes. Trouble-free power supply must also be assured at all times. Our cables and system solutions are therefore applied precisely in areas where dependability is a top priority and outstanding heat resistance, high power handling capacity, ruggedness and compact design are a must. Multi core cables, single core cables and system solutions • RADOX® multi core and single core cables • RADOX® eco-F single core cables • RADOX® UL cables RADOX® multi core and single core cables have a high power handling capacity and heat resistance. They have been specifically designed for the construction of high-performance, compact and light-weight equipment. • • • • • outstanding heat resistance high power handling capacity ruggedness and compact design high flexibility easy processing See table overview on pages 18 and 19. HUBER+SUHNER 7 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=8</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=8</link><title>HUBER+SUHNER   Low Frequency Page 8</title><description>8 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=9</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=9</link><title>HUBER+SUHNER   Low Frequency Page 9</title><description>Single core/multi core cables for power and signal transmission in automation applications The field of industrial automation has extremely rigorous demands on the performance and quality of the cables used. A cable will achieve top performance only if it offers absolute flexibility and a long service life. In addition, these products must satisfy highly specific customer requirements. Our modular system is the ideal solution for responding to such needs. Top quality cables for industrial automation applications with a long service life • RADOX® multi core and single core cables, screened and unscreened • hybrid cables Our single core and multi core cables are distinguished by their thin insulation walls and their tight bending radius. The hybrid cables offer a multi functional solution in a single cable. • • • • • • thin insulation walls tight bending radii high flexibility abrasion resistance high current carrying capacity long service life See table overview on pages 18 and 19. HUBER+SUHNER 9 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=10</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=10</link><title>HUBER+SUHNER   Low Frequency Page 10</title><description>10 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=11</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=11</link><title>HUBER+SUHNER   Low Frequency Page 11</title><description>Single core/multi core cables for power and signal transmission in coil winding applications RADOX® eco-F and RADOX® 155 are flexible single core and multi core cables offering excellent resistance to heat, hot pressure and aging. The electronically crosslinked insulation offers high mechanical ruggedness. It will not melt and is resistant to most media as well as insulating varnishes and impregnating resins. Brief exposure to heat up to +280 °C will not have any lasting effect. The insulation of RADOX® eco-F is halogen free and will not release any corrosive gases in case of a fire. It generates minimum smoke, and its flame retarding properties prevent fires from spreading. You will find more detailed information and the description of additional products for the coil winding products industry in the "RADOX® wires and cables for the coil winding industry" catalogue, item no. 84022718. Flexible single core cables and wires for coil winding products • RADOX® 155, wires and flexible cables • RADOX® eco-F • RADOX® UL and KDJ cables These transmission lines offer high power handling capacity and heat resistance. They require little space and therefore allow the construction of high performance yet compact and light weight equipment. See table overview on pages 18 and 19. HUBER+SUHNER 11 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=12</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=12</link><title>HUBER+SUHNER   Low Frequency Page 12</title><description>12 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=13</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=13</link><title>HUBER+SUHNER   Low Frequency Page 13</title><description>Single core and multi core cables for power and signal transmission in marine applications Our RADOX® insulation material for cables was developed with special applications in mind which require high reliability even under adverse environmental conditions. It offers excellent resistance to heat and chemicals as well as to electrical and mechanical stressing. Our single-core and multicore cable solutions for marine applications are suitable for stationary as well as mobile uses. They have small diameters, standardised dimensions and require only a short time to install. Marine cables with GL, DNV and BV approvals • RADOX® 125 IEC marine transmission line • RADOX® MFH control, data and power transmission lines for marine applications These cable types are particularly distinguished by their resistance to fuels and lubricants, alkalis and acids. • light weight, space saving hybrid solutions meeting the most rigorous demands • highly abrasion resistant single cores for corrugated copper cables • customised, multifunctional system cables • versatile cable and element combinations • high temperature data bus for marine applications See table overview on pages 18 and 19. HUBER+SUHNER 13 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=14</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=14</link><title>HUBER+SUHNER   Low Frequency Page 14</title><description>14 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=15</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=15</link><title>HUBER+SUHNER   Low Frequency Page 15</title><description>Single core and multi core cables for power and signal transmission in solar applications RADOX® solar cables are extremely rugged and abrasion-resistant and are capable of withstanding extreme mechanical stressing. Their high temperature and excellent weatherproof ensure a long service life of the cable. Thanks to the technology and high precision of RADOX® products, these outstanding characteristics are achieved also with small diameters. You will find more detailed information and the description of additional products for the PV industry in the "RADOX® SOLAR" catalogue, item no. 84017606. Solar cables with TÜV and UL approval • RADOX® solar cable single and multiple core/screened • RADOX® SMART • RADOX® SolarLink RADOX® solar cables are flexible single core and multi core cables that have been specially designed for the wiring of solar systems. • range of application –40 °C to +120 °C • short circuit strength up to +250 °C • RADOX® electronic cross linked materials will neither melt nor flow even when exposed to high temperatures • high UV, ozone and hydrolysis resistance • excellent mechanical ruggedness and resistance to water, oils and chemicals • proven of many years of field application worldwide • TÜV and UL approvals • connectors and connection boxes available See table overview on pages 18 and 19. HUBER+SUHNER 15 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=16</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=16</link><title>HUBER+SUHNER   Low Frequency Page 16</title><description>16 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=17</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=17</link><title>HUBER+SUHNER   Low Frequency Page 17</title><description>Single core and multi core cables for power and signal transmission in safety applications Installations in buildings and systems with a high person density or high property value – computer centres, hospitals, high-rise buildings, airports, railway stations, public buildings, museums, railway and road tunnels – require high grade cables designed to the necessary standards. These cable families are distinguished by their precisely defined characteristics and the fact that they will maintain their functions in case of fires. They comply with the major international standards. High grade cables fulfilling various international fire protection regulations • RADOX® FR AUS • RADOX® FR INT Our safety cables have been designed for service in adverse and humid environments. • • • • • maintenance of functions in case of fire application in rough and humid environments high flexibility approved by major international standardisation bodies customised cables See table overview on pages 18 and 19. HUBER+SUHNER 17 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=18</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=18</link><title>HUBER+SUHNER   Low Frequency Page 18</title><description>18 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=19</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=19</link><title>HUBER+SUHNER   Low Frequency Page 19</title><description>Single core/multi core cables for power and signal transmission in defence applications HUBER+SUHNER develops and produces high grade solutions that are suitable for the most extreme environmental conditions. They can be installed in very tight spaces and will satisfy even the most stringent demands. HUBER+SUHNER is the professional partner in the development and production of system solutions which incorporate all our knowledge and engineering expertise. Unpredictabel conditions, fulfilment of extreme environmental and operating requirements while meeting top quality standards. • RADOX® single core and multi core cables • VG transmission lines • Hybrid cables • Various MIL styles RADOX® single core and multi core cables have been developed and are produced for high grade defence solutions. • • • • • • wide temperature range stationary as well as mobile applications small overall diameter flexible and rugged light weight and space saving solutions chemical and mechanical resistance See table overview on pages 18 and 19. HUBER+SUHNER 19 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=20</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=20</link><title>HUBER+SUHNER   Low Frequency Page 20</title><description>Preferred fields of application Cable type RADOX® 125 flexible single core RADOX® 125 RW, reduced wall thickness RADOX® 125 IEC marine single core RADOX® 125 solid wire RADOX® eco-F RADOX® 155 flexible single core RADOX® 155 S high resistance to oil RADOX® 155 S RW, reduced wall thickness RADOX® 155 solid wire KDJ-11, flexible single core RADOX® 125 multi core cables, screened and unscreened RADOX® 155 multi core cables, screened and unscreened RADOX® UL/CSA flexible single core RADOX® UL/CSA solid wire RADOX® UL/CSA multi core cables, screened and unscreened System cables MIL and VG 95218 div. types RADOX® MFH Hybrid cables RADOX® Solar single core cables RADOX® Solar multi core cables, screened and unscreened RADOX® FR page 102 page 104 page 104 page 28 page 30 page 32 page 34 page 36 page 38 page 40 page 42 page 46 page 52 page 60 page 62 page 72 page 72 page 80 Industry page 22 page 24 Automation 20 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=21</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=21</link><title>HUBER+SUHNER   Low Frequency Page 21</title><description>Coil winding (catalogue no. 84022718) Marine Solar (catalogue no. 84017606) Safety page 22 Defence page 26 page 28 page 30 page 32 page 38 page 42 page 52 page 72 page 80 page 102 page 104 page 108 page 114 page 120 page 102 page 104 HUBER+SUHNER 21 Introduction</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=22</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=22</link><title>HUBER+SUHNER   Low Frequency Page 22</title><description>22 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=23</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=23</link><title>HUBER+SUHNER   Low Frequency Page 23</title><description>RADOX® 125, RADOX® 155, KDJ–11 ® 125, RADOX® ® 155, RADOX® KDJ-11 KDJ-11 Flexible single cores, multi core cables and wires RADOX® 125, flexible single core RADOX® 125 RW, reduced wall thickness RADOX® 125 IEC marine single core RADOX® 125 solid wire RADOX® eco–F RADOX® 155, flexible single core RADOX® 155 S, high resistance to oil RADOX® 155 S RW, reduced wall thickness RADOX® 155, solid wire RADOX® KDJ–11, flexible single core RADOX® 125, multi core cable RADOX® 125, multi core cable, screened RADOX® 155, multi core cable RADOX® 155, multi core cable, screened 22 24 26 28 30 32 34 36 38 40 42 44 46 48 All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS). HUBER+SUHNER 23</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=24</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=24</link><title>HUBER+SUHNER   Low Frequency Page 24</title><description>RADOX® 125 Flexible single core     • excellent high and low temperature and ozone resistance • weatherproof • halogen free • flexible, easy to strip and process • high resistance to thermal pressure • high abrasion resistance • oil–resistant Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, white goods and lighting fixtures. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range The cables are in conformity with: Halogen--free compound Corrosivityofcombustiongases Amountofhalogenacidgas Contentoffluorine stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 125 extruded and electron beam crosslinked polyolefin copolymer various, on request ≤0.50mm2 ≤0.50mm2 &gt; 0.50 mm2 &gt; 0.50 mm2 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –40 °C up to +125 °C fulfilled pH≥4.3,σ≤10μS/mm HCI+HBr≤0.5% HF≤0.1% EN 50363 EN50267--2--2 EN50267--2--1 EN60684--2,#45.2 24 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=25</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=25</link><title>HUBER+SUHNER   Low Frequency Page 25</title><description>RADOX® 125 RADOX® 125, RADOX® 155, KDJ-11 Flexible single core Extract from our delivery programme Cross section nom. mm2 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 Construction nom. n x mm dia. 19 x 0.13 19 x 0.16 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 50 x 0.25 56 x 0.30 81 x 0.30 78 x 0.40 119 x 0.40 182 x 0.40 266 x 0.40 378 x 0.40 348 x 0.50 444 x 0.50 551 x 0.50 722 x 0.50 874 x 0.50 1147 x 0.50 Conductor dia. max. mm 0.6 0.8 0.9 1.15 1.3 1.55 2.05 2.6 3.4 4.4 5.4 6.7 7.9 9.4 11.5 12.9 14.8 17.0 18.5 21.3 R20 IEC 60228 max.Ω/km 85.9 52.1 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 Core dia. mm 1.45 ± 0.05 1.60 ± 0.10 1.70 ± 0.10 2.20 ± 0.10 2.60 ± 0.10 2.73 ± 0.10 3.50 ± 0.10 4.15 ± 0.15 4.95 ± 0.15 6.15 ± 0.15 7.35 ± 0.15 8.9 ± 0.2 10.3 ± 0.2 12.1 ± 0.25 14.4 ± 0.25 16.0 ± 0.3 18.6 ± 0.3 20.5 ± 0.3 22.2 ± 0.3 25.4 ± 0.3 Weight nom. kg/100m 0.4 0.5 0.7 1.1 1.5 1.9 3.0 4.6 6.7 11 16.5 25 34.9 50 70.8 89 116 145 173 225 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. Bending radius min. Various colours on request. HUBER+SUHNER 25</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=26</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=26</link><title>HUBER+SUHNER   Low Frequency Page 26</title><description>RADOX® 125 RW Flexible single core – reduced wall thickness     • excellent high and low temperature and ozone resistance • weatherproof • halogen free • flexible, easy to strip and process • high resistance to heat pressure • high abrasion resistance • reduced wall thickness • soldering resistant Application Protected and fixed installation inside electrical equipment. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Test voltage Temperature range Min. bending radius The cables are in conformity with: Halogen--free compound Corrosivityofcombustiongases Amountofhalogenacidgas Contentoffluorine stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 125 extruded and electron beam crosslinked polyolefin copolymer various, on request (UL rating) 300 / 500 V AC 2500 V AC –40 °C up to +125 °C 3 x core–dia. fulfilled pH≥4.3,σ≤10μS/mm HCI+HBr≤0.5% HF≤0.1% EN 50363 EN50267--2--2 EN50267--2--1 EN60684--2,#45.2 26 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=27</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=27</link><title>HUBER+SUHNER   Low Frequency Page 27</title><description>RADOX® 125 RW RADOX® 125, RADOX® 155, KDJ-11 27 Flexible single core – reduced wall thickness Extract from our delivery programme Cross section nom. mm2 0.34 0.50 0.75 1.0 Construction nom. n x mm dia. 19 x 0.16 19 x 0.18 19 x 0.23 9 x 0.25 Conductor dia. max. mm 0.77 0.9 1.1 1.25 R20 IEC 60228 max.Ω/km 53.1 40.1 26.7 21.5 Core dia. mm 1.25 + 0.05 1.40 + 0.05 1.65 + 0.05 1.75 + 0.05 Weight nom. kg/100 m 0.41 0.56 0.83 1.00 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=28</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=28</link><title>HUBER+SUHNER   Low Frequency Page 28</title><description>RADOX® 125 IEC Marine single core     • excellent high and low temperature and ozone resistance • weatherproof • halogen free • flame retardant • high abrasion resistance • soldering resistant • low smoke • easy to strip and process • flexible • electron beam crosslinked insulation Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of general power devices, lighting and switchboards. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Test voltage Temperature range Temperature range IEC 60092 Short circuit temperature IEC 60092 Min. bending radius stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 125 extruded and electron beam crosslinked polyolefin copolymer various, on request Ø &lt; 12 mm Ø &gt; 12 mm 600 / 1000 V AC 3500 V AC –25 up to +110 °C +90 °C +250 °C 3 x core–dia. 4 x core–dia. Approvals DET NORSKE VERITAS (DNV) Classification of ships and mobile offshore units, IEC 60092–353, IEC 60332–3–22 cat. A, IEC 61034–2, IEC 60754–2 (cross section 1.5 – 300 mm2) BUREAU VERITAS (BV) Classification of steel ships, IEC 60092–353, IEC 60332–3–22 cat. A, IEC 61034–2, IEC 60754–2 (cross section 1.5 – 300 mm2) 28 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=29</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=29</link><title>HUBER+SUHNER   Low Frequency Page 29</title><description>RADOX® 125 IEC RADOX® 125, RADOX® 155, KDJ-11 Weight nom. kg/100 m 1.1 1.3 1.6 2.2 3.1 4.8 6.5 11.0 16.3 24.4 34.3 50.2 68.8 87.9 109 140 170 226 276 29 Marine single core The cables are in conformity with: Fire protection in ships Verticalflamespread Verticalflamespread,bunched Smokedensity Corrosivityofcombustiongases Amountofhalogenacidgas Extract from our delivery programme Cross section nom. mm2 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 nom. n x mm dia. 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 48 x 0.25 56 x 0.30 81 x 0.30 78 x 0.40 119 x 0.40 182 x 0.40 266 x 0.40 378 x 0.40 348 x 0.50 444 x 0.50 551 x 0.50 722 x 0.50 874 x 0.50 1147 x 0.50 1443 x 0.50 Conductor dia. max. mm 0.95 1.2 1.3 1.6 2.1 2.6 3.4 4.4 5.4 6.7 7.9 9.4 11.5 12.9 14.8 17.0 18.5 21.3 23.9 R20 IEC 60228 max.Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 Core dia. mm 2.40 ± 0.10 2.65 ± 0.10 2.80 ± 0.10 3.05 ± 0.10 3.55 ± 0.10 4.20 ± 0.15 4.85 ± 0.15 5.85 ± 0.15 6.95 ± 0.15 8.70 ± 0.20 9.90 ± 0.20 11.6 ± 0.20 14.0 ± 0.25 15.4 ± 0.25 17.8 ± 0.30 20.0 ± 0.30 22.0 ± 0.30 25.0 ± 0.30 27.8 ± 0.30 fulfilled 50&lt;L≤540mm L≤2.5m T≥60% pH≥4.3,C≤10mS/mm HCl+HBr≤0.5% IEC 60092 IEC60332--1--2 IEC60332--3--22 IEC61034--2 IEC60754--2 IEC60754--1 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=30</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=30</link><title>HUBER+SUHNER   Low Frequency Page 30</title><description>RADOX® 125 Solid wire     • excellent high and low temperature and ozone resistance • halogen free • high resistance to heat pressure • high abrasion resistance • easy to process • soldering resistant Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of switchboards, magnets and transformers. Composition of the cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. bending radius The cables are in conformity with: Halogen--free compound Corrosivityofcombustiongases Amountofhalogenacidgas Contentoffluorine stranded bare or tin plated copper, acc. to EN 60228, class 1 RADOX® 125 extruded and electron beam crosslinked polyolefin copolymer various, on request ≤0.50mm2 ≤0.50mm2 &gt; 0.50 mm2 &gt; 0.50 mm2 450 / 750 V AC 2500 V AC 600/1000 V AC 3500 V AC –40 °C up to +125 °C 3 x wire–dia. fulfilled pH≥4.3,σ≤10μS/mm HCI+HBr≤0.5% HF≤0.1% EN 50363 EN50267--2--2 EN50267--2--1 EN60684--2,#45.2 30 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=31</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=31</link><title>HUBER+SUHNER   Low Frequency Page 31</title><description>RADOX® 125 RADOX® 125, RADOX® 155, KDJ-11 31 Solid wire Extract from our delivery programme Cross section nom. mm2 0.50 0.75 1.0 1.5 dia. max. mm 0.8 1.0 1.15 1.4 Conductor R20 IEC 60228 max.Ω/km 36.7 24.8 18.2 12.2 Core dia. mm 1.90 ± 0.10 2.10 ± 0.10 2.35 ± 0.10 2.60 ± 0.10 Weight nom. kg/100 m 0.8 1.0 1.4 1.9 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=32</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=32</link><title>HUBER+SUHNER   Low Frequency Page 32</title><description>RADOX® eco–F Flexible single core     • excellent high and low temperature and ozone resistance • weatherproof • halogen free • easy to process • soldering resistant • flexible • resistant to impregnation resins and varnishes Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, white goods, lighting fixtures, etc. Composition of cable  Conductor  Insulation Core colours stranded tin plated copper RADOX® eco–F, extruded and electron beam crosslinked polyolefin various, on request Technical data Voltage rating Uo/U Test voltage Min. operating temperature Max. continuous conductor temperature Max. continuous conductor temperature at short circuit (max. 5s) fixed flexing Min. bending radius The cables are in conformity with: Halogen--free compound Corrosivityofcombustiongases Amountofhalogenacidgas Contentoffluorine 450 / 750 V AC 2500 V AC –40 °C +125 °C +250 °C +200 °C 3 x core–dia. fulfilled pH≥4.3,σ≤10μS/mm HCI+HBr≤0.5% HF≤0.1% EN 50363 EN50267--2--2 EN50267--2--1 EN60684--2,#45.2 32 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=33</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=33</link><title>HUBER+SUHNER   Low Frequency Page 33</title><description>RADOX® eco–F RADOX® 125, RADOX® 155, KDJ-11 33 Flexible single core Extract from our delivery programme Cross section nom. mm2 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 Construction nom. n x mm dia. 19 x 0.13 19 x 0.16 19 x 0.18 19 x 0.23 19 x 0.26 30 x 0.25 48 x 0.25 56 x 0.30 Conductor dia. max. mm 0.6 0.8 0.9 1.1 1.2 1.5 2.1 2.6 R20 IEC 60228 max.Ω/km 85.9 52.1 40.1 26.7 20.0 13.7 8.21 5.09 Core dia. mm 1.35 ± 0.05 1.60 ± 0.10 1.71 ± 0.10 1.90 ± 0.10 2.15 ± 0.10 2.45 ± 0.10 3.05 ± 0.10 3.65 ± 0.15 Weight nom. kg/100 m 0.4 0.6 0.7 1.0 1.2 1.8 2.8 4.7 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=34</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=34</link><title>HUBER+SUHNER   Low Frequency Page 34</title><description>RADOX® 155 Flexible single core     • excellent high and low temperature and ozone resistance • weatherproof • easy to process • high resistance to heat pressure • high abrasion resistance • soldering resistant • flexible • resistant to impregnation resins and varnishes Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer various, on request ≤0.50mm2 ≤0.50mm2 &gt; 0.50 mm2 &gt; 0.50 mm2 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –55 °C up to +155 °C 34 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=35</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=35</link><title>HUBER+SUHNER   Low Frequency Page 35</title><description>RADOX® 155 RADOX® 125, RADOX® 155, KDJ-11 Flexible single core Extract from our delivery programme Cross section nom. mm2 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 Construction nom. n x mm dia. 19 x 0.13 19 x 0.16 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 48 x 0.25 56 x 0.30 81 x 0.30 78 x 0.40 119 x 0.40 182 x 0.40 266 x 0.40 378 x 0.40 348 x 0.50 444 x 0.50 551 x 0.50 722 x 0.50 874 x 0.50 1147 x 0.50 Conuctor dia. max. mm 0.6 0.8 0.9 1.15 1.3 1.55 2.05 2.6 3.4 4.4 5.4 6.7 7.9 9.4 11.5 12.9 14.8 17.0 18.5 21.3 R20 IEC 60228 max.Ω/km 85.9 52.1 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 Core dia. mm 1.45 ± 0.05 1.60 ± 0.10 1.70 ± 0.10 2.20 ± 0.10 2.60 ± 0.10 2.70 ± 0.10 3.35 ± 0.10 4.05 ± 0.15 5.2 ± 0.15 6.4 ± 0.15 7.6 ± 0.15 9.2 ± 0.2 10.6 ± 0.2 12.3 ± 0.25 14.6 ± 0.25 16.3 ± 0.3 18.4 ± 0.3 20.8 ± 0.3 22.5 ± 0.3 25.7 ± 0.3 Weight nom. kg/100 m 0.4 0.5 0.7 1.1 1.5 1.9 3.0 4.6 6.5 11 16.5 25 34.5 50 68 89 110 142 171 225 Bending radius min. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. Various colours on request. HUBER+SUHNER 35</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=36</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=36</link><title>HUBER+SUHNER   Low Frequency Page 36</title><description>RADOX® 155 S Flexible single core – high oil resistance     • excellent high and low temperature and ozone resistance • weatherproof • high resistance to heat pressure • high abrasion resistance • easy to strip and process • resistant to hydrolysis, oil and fuels • resistant to impregnation resins and varnishes Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. bending radius stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 155 S extruded electron beam crosslinked polyolefin copolymer various, on request ≤0.50mm2 ≤0.50mm2 &gt; 0.50 mm2 &gt; 0.50 mm2 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –55 °C up to +155 °C 3 x core–dia. 36 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=37</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=37</link><title>HUBER+SUHNER   Low Frequency Page 37</title><description>RADOX® 155 S RADOX® 125, RADOX® 155, KDJ-11 37 Flexible single core – high oil resistance Extract from our delivery programme Cross section nom. mm2 0.50 0.75 1.0 1.5 2.5 4.0 6.0 Construction nom. n x mm dia. 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 48 x 0.25 56 x 0.25 81 x 0.25 Conductor dia. max. mm 0.9 1.15 1.3 1.55 2.05 2.6 3.4 R20 IEC 60228 max.Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 Core dia. mm 1.70 ± 0.10 2.20 ± 0.10 2.60 ± 0.10 2.70 ± 0.10 3.50 ± 0.10 4.15 ± 0.15 5.20 ± 0.15 Weight nom. kg/100 m 0.7 1.1 1.5 1.9 3.0 4.5 6.6 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=38</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=38</link><title>HUBER+SUHNER   Low Frequency Page 38</title><description>RADOX® 155 S RW Flexible single core – reduced wall thickness     • reduced wall thickness • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high abrasion resistance • easy to strip and process • resistant to hydrolysis, oil and fuels • resistant to impregnation resins and varnishes Applications Protected and fixed installation inside equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers where space is rare. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Test voltage Temperature range Min. bending radius stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 155 S extruded and electron beam crosslinked polyolefin copolymer various, on request 300 / 500 V AC 2000 V AC –40 °C up to +155 °C 3 x core–dia. 38 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=39</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=39</link><title>HUBER+SUHNER   Low Frequency Page 39</title><description>RADOX® 155 S RW RADOX® 125, RADOX® 155, KDJ-11 39 Flexible single core – reduced wall thickness Extract from our delivery programme Cross section nom. mm2 0.14 0.25 0.35 0.50 0.75 1.0 1.5 2.5 4.0 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.15 19 x 0.18 19 x 0.22 19 x 0.26 30 x 0.26 50 x 0.26 56 x 0.31 Conductor dia. max. mm 0.51 0.61 0.80 0.91 1.12 1.26 1.7 2.2 2.75 R20 IEC 60228 max.Ω/km 135.5 86.0 54.5 38.2 25.4 19.1 13.0 7.8 4.8 Core dia. mm 0.95 ± 0.05 1.10 ± 0.05 1.25 ± 0.05 1.40 ± 0.05 1.65 ± 0.05 1.75 ± 0.05 2.30 ± 0.1 2.85 ± 0.15 3.55 ± 0.15 Weight nom. kg/100 m 0.3 0.3 0.4 0.6 0.8 1.0 1.6 2.6 4.2 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=40</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=40</link><title>HUBER+SUHNER   Low Frequency Page 40</title><description>RADOX® 155 Solid wire     • excellent high and low temperature and ozone resistance • weatherproof • high resistance to heat pressure • high abrasion resistance • soldering resistant • easy to process • resistant to impregnation resins and varnishes Applications Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. bending radius stranded bare or tin plated copper, acc. to EN 60228, class 1 RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer various, on request ≤0.50mm2 ≤0.50mm2 &gt; 0.50 mm2 &gt; 0.50 mm2 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –55 °C up to +155 °C 3 x wire–dia. 40 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=41</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=41</link><title>HUBER+SUHNER   Low Frequency Page 41</title><description>RADOX® 155 RADOX® 125, RADOX® 155, KDJ-11 41 Solid wire Extract from our delivery programme Cross section nom. mm2 0.50 0.75 1.0 1.5 dia. max. mm 0.8 1.0 1.15 1.4 Conductor R20 IEC 60228 max.Ω/km 36.7 24.8 18.2 12.2 Core dia. mm 1.90 ± 0.10 2.10 ± 0.10 2.35 ± 0.10 2.60 ± 0.10 Weight nom. kg/100 m 0.8 1.0 1.4 1.9 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=42</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=42</link><title>HUBER+SUHNER   Low Frequency Page 42</title><description>RADOX® KDJ–11 Flexible single core     • resistant to solvents, oils, fuels, alkaline solutions, acids and hydrolysis • weatherproof • impermeable to vapour • compact design • mechanical robustness in agressive environment at high and low temperatures Application • Wiring of equipment for heating and refrigeration units, chemical plants, wet or humid rooms and rooms with high ambient temperatures. • Compatible to moudling compounds. • Transformer in oil, class H motors. Composition of cable  Conductor  Insulation Core colours Technical data Voltage rating Uo/U Test voltage Max. conductor temperature Short circuit temperature Min. operating temperature Min. bending radius stranded bare copper, acc. to EN 60228, class 5 FEP various, on request 0.50 and 1.0 mm2 1.50 up to 25 mm2 (continuous) (max. 5s) fixed flexing fixed flexing 300 / 500 V AC 450 / 750 V AC 2500 V AC +180 °C +250 °C –100 °C –55 °C 3 x core–dia. 5 x core–dia. 42 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=43</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=43</link><title>HUBER+SUHNER   Low Frequency Page 43</title><description>RADOX® KDJ–11 RADOX® 125, RADOX® 155, KDJ-11 43 Flexible single core Extract from our delivery programme Cross section nom. mm2 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 Construction nom. n x mm dia. 19 x 0.18 24 x 0.20 32 x 0.20 19 x 0.32 50 x 0.25 56 x 0.30 84 x 0.30 80 x 0.40 Conductor dia. max. mm 0.91 1.16 1.33 1.63 1.98 2.50 2.98 3.94 R20 IEC 60228 max.Ω/km 37.1 24.7 18.5 12.6 7.58 4.70 3.14 1.87 Core dia. mm 1.85 2.10 2.30 2.60 3.20 3.80 4.90 5.50 Weight nom. kg/100 m 0.8 1.2 1.4 2.0 3.0 4.3 6.8 11.1 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=44</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=44</link><title>HUBER+SUHNER   Low Frequency Page 44</title><description>RADOX® 125 Multi core cable     • excellent high and low temperature and ozone resistance • weatherproof • halogen free • flame retardant • soldering resistant • flexible • in case of fire no corrosive gases and low smoke emission • easy to strip    Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Core: Conductor Insulation Core colours  Fillers (optional)  Separator  Sheath Colour Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. operating temperature Max. conductor temperature Min. bending radius Fire tests Flame propagation: Verical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 125 extruded and electron beam crosslinked polyolefin copolymer 2 up to 5 core acc. to CENELEC HD 308 (see page 139) 6 core and more: black numbered with yellow/green earthing RADOX® 125 plastic tape RADOX® 125M: extruded and electron beam crosslinked polyolefin copolymer black ≤16x0.50mm2 ≤16x0.50mm2 &gt; 16 x 0.50 mm2 &gt; 16 x 0.50 mm2 fixed flexing at short circuit (max. 5s) fixed flexing 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –40 °C up to +125 °C –25 °C +280 °C 3 x cable–dia. 5 x cable–dia. EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 EN 50267–2–1, IEC 60754–1 EN 50267–2–2, IEC 60754–2 EN 50268–2, IEC 61034–2 Category C 0 mg/g 44 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=45</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=45</link><title>HUBER+SUHNER   Low Frequency Page 45</title><description>RADOX® 125 RADOX® 125, RADOX® 155, KDJ-11 45 Multi core cable Extract from our delivery programme Cross section n x mm2 4 x 0.25 4 x 0.5 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.0 3 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 4 x 4.0 5 x 4.0 4 x 10 5 x 10 Construction nom. n x mm dia. 19 x 0.12 19 x 0.18 24 x 0.20 24 x 0.20 24 x 0.20 24 x 0.20 32 x 0.20 32 x 0.20 30 x 0.25 30 x 0.25 30 x 0.25 30 x 0.25 30 x 0.25 50 x 0.25 50 x 0.25 50 x 0.25 50 x 0.25 56 x 0.30 56 x 0.30 78 x 0.40 78 x 0.40 Conductor dia. max. mm 0.61 0.9 1.15 1.15 1.15 1.15 1.3 1.3 1.55 1.55 1.55 1.55 1.55 2.05 2.05 2.05 2.05 2.6 2.6 4.4 4.4 R20 IEC 60228 max.Ω/km 88.5 40.1 26.7 26.7 26.7 26.7 20.0 20.0 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 5.09 5.09 1.95 1.95 Core dia. mm 1.45 ± 0.05 1.7 ± 0.10 2.2 ± 0.10 2.2 ± 0.10 2.2 ± 0.10 2.2 ± 0.10 2.6 ± 0.10 2.6 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 4.15 ± 0.15 4.15 ± 0.15 6.15 ± 0.15 6.15 ± 0.15 Cable dia. mm 5.4 ± 0.3 6.1 ± 0.3 6.6 ± 0.3 7.3 ± 0.3 7.7 ± 0.3 8.6 ± 0.3 7.5 ± 0.3 7.9 ± 0.3 7.8 ± 0.3 8.3 ± 0.3 9.2 ± 0.3 10.4 ± 0.4 12.3 ± 0.4 9.1 ± 0.3 10.1 ± 0.4 11.3 ± 0.4 12.4 ± 0.4 13.0 ± 0.4 14.6 ± 0.4 19.0 ± 0.5 21.4 ± 0.5 Weight nom. kg/100 m 4.0 6.5 6.3 7.9 8.8 10.9 7.4 9.1 8.6 11.0 13.6 16.8 23.6 13.0 16.6 20.9 24.9 29.8 36.7 78.2 83.3 Other cross sections on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=46</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=46</link><title>HUBER+SUHNER   Low Frequency Page 46</title><description>RADOX® 125 Multi core cable – screened       • excellent high and low temperature and ozone resistance • weatherproof • halogen free • flame retardant • soldering resistant • flexible • in case of fire no corrosive gases and low smoke emission • easy to strip     Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Core: Conductor Insulation Core colours      Fillers (optional) Separator (optional) Screen Separator (optional) Sheath Colour Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. operating temperature Max. conductor temperature Min. bending radius Fire tests Flame propagation: Verical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density 46 stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 125 extruded and electron beam crosslinked polyolefin copolymer 2 up to 5 core acc. to CENELEC HD 308 (see page 139) 6 core and more: black numbered with yellow/green earthing other colours on request RADOX® 125 plastic tape copper braid, optical coverage:≥85% plastic tape RADOX® 125M extruded and electron beam crosslinked polyolefin copolymer black ≤16x0.50mm2 ≤16x0.50mm2 &gt; 16 x 0.50 mm2 &gt; 16 x 0.50 mm2 fixed flexing at short circuit (max. 5s) fixed flexing 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –40 °C up to +125 °C –25 °C +280 °C 4 x cable–dia. 5 x cable–dia. EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 EN 50267–2–1, IEC 60754–1 EN 50267–2–2, IEC 60754–2 EN 50268–2, IEC 61034–2 Category C 0 mg/g HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=47</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=47</link><title>HUBER+SUHNER   Low Frequency Page 47</title><description>RADOX® 125 RADOX® 125, RADOX® 155, KDJ-11 47 Multi core cable – screened Extract from our delivery programme Cross section Construction nom. n x mm dia. 19 x 0.13 19 x 0.18 19 x 0.18 24 x 0.20 24 x 0.20 24 x 0.20 32 x 0.20 32 x 0.20 32 x 0.20 30 x 0.25 30 x 0.25 50 x 0.25 50 x 0.25 Conductor dia. max. mm 0.6 0.9 0.9 1.15 1.15 1.15 1.3 1.3 1.3 1.55 1.55 2.05 2.05 R20 IEC 60228 max.Ω/km 85.9 40.1 40.1 26.7 26.7 26.7 20.0 20.0 20.0 13.7 13.7 8.21 8.21 Core dia. mm 1.45 ± 0.05 1.7 ± 0.10 1.7 ± 0.10 2.2 ± 0.10 2.2 ± 0.10 2.2 ± 0.10 2.6 ± 0.10 2.6 ± 0.10 2.6 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 Screen dia. mm 4.1 4.0 4.8 4.9 5.5 6.2 5.9 6.3 7.0 6.5 7.6 9.8 10.4 Cable dia. mm 5.9 ± 0.3 5.9 ± 0.3 6.8 ± 0.3 6.9 ± 0.3 7.6 ± 0.3 8.4 ± 0.3 7.9 ± 0.3 8.7 ± 0.3 9.3 ± 0.3 8.7 ± 0.3 10.0 ± 0.4 12.4 ± 0.4 13.1 ± 0.4 Weight nom. kg/100 m 5.2 5.7 8.0 7.4 9.7 11.7 10.6 12.7 14.4 13.2 17.5 26.8 30.9 n x mm2 4 x 0.25 2 x 0.5 4 x 0.5 2 x 0.75 3 x 0.75 4 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 3 x 1.5 4 x 1.5 4 x 2.5 5 x 2.5 Other cross sections on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=48</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=48</link><title>HUBER+SUHNER   Low Frequency Page 48</title><description>RADOX® 155 Multi core cable     • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • soldering resistant • flexible • easy to strip    Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Core: Conductor Insulation Core colours  Fillers (optional)  Separator (optional)  Sheath Colour Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. operating temperature Max. conductor temperature Min. bending radius stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer 2 up to 5 core acc. to CENELEC HD 308 (see page 139) 6 core and more: black numbered with yellow/green earthing other colours on request RADOX® 125 plastic tape RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer black ≤16x0.50mm2 ≤16x0.50mm2 &gt; 16 x 0.50 mm2 &gt; 16 x 0.50 mm2 fixed flexible at short circuit (max. 5s) fixed flexible 450 / 750 V AC 2500 V AC 600 / 1000 V AC 3500 V AC –55 °C up to +155 °C –40 °C +280 °C 3 x cable–dia. 5 x cable–dia. 48 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=49</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=49</link><title>HUBER+SUHNER   Low Frequency Page 49</title><description>RADOX® 155 RADOX® 125, RADOX® 155, KDJ-11 49 Multi core cable Extract from our delivery programme Cross section n x mm2 4 x 0.25 3 x 0.34 2 x 0.50 3 x 0.50 8 x 0.50 16 x 0.50 3 x 0.75 4 x 0.75 2 x 1.0 3 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 3 x 2.5 4 x 2.5 5 x 2.5 Construction nom. n x mm dia. 19 x 0.13 19 x 0.15 19 x 0.18 19 x 0.18 19 x 0.18 19 x 0.18 24 x 0.20 24 x 0.20 32 x 0.20 32 x 0.20 30 x 0.25 30 x 0.25 30 x 0.25 30 x 0.25 50 x 0.25 50 x 0.25 50 x 0.25 Conductor dia. max. mm 0.6 0.75 0.9 0.9 0.9 0.9 1.15 1.15 1.3 1.3 1.55 1.55 1.55 1.55 2.05 2.05 2.05 R20 IEC 60228 max.Ω/km 85.9 57.2 40.1 40.1 40.1 40.1 26.7 26.7 20.0 20.0 13.7 13.7 13.7 13.7 8.21 8.21 8.21 Core dia. mm 1.45 ± 0.05 1.55 ± 0.10 1.7 ± 0.10 1.7 ± 0.10 1.7 ± 0.10 1.7 ± 0.10 2.2 ± 0.10 2.2 ± 0.10 2.6 ± 0.10 2.6 ± 0.10 2.7 ± 0.10 2.7 ± 0.10 2.7 ± 0.10 2.7 ± 0.10 3.35 ± 0.10 3.35 ± 0.10 3.35 ± 0.10 Cable dia. mm 5.4 ± 0.3 5.1 ± 0.3 5.2 ± 0.3 5.6 ± 0.3 8.75 ± 0.3 10.4 ± 0.4 6.7 ± 0.3 7.5 ± 0.3 7.0 ± 0.3 7.6 ± 0.3 7.5 ± 0.3 7.9 ± 0.3 8.8 ± 0.3 10.1 ± 0.4 9.9 ± 0.3 11.0 ± 0.4 11.9 ± 0.4 Weight nom. 3.3 – – 4.0 – – 5.9 – 6.1 7.7 6.6 9.2 11.7 15.0 14.6 18.6 22.3 Other cross sections on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=50</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=50</link><title>HUBER+SUHNER   Low Frequency Page 50</title><description>RADOX® 155 Multi core cable – screened       • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • soldering resistant • flexible • easy to strip     Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Core: Conductor Insulation Core colours  Fillers (optional)  Separator (optional)  Screen  Separator (optional)  Sheath Colour Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Test voltage Temperature range Min. operating temperature Max. conductor temperature Min. bending radius stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer 2 up to 5 core acc. to CENELEC HD 308 (see page 139) 6 core and more: black numbered with yellow/green earthing other colours on request RADOX® 125 plastic tape copperbraid,opticalcoverage:≥85% plastic tape RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer black ≤16x0.50mm2 ≤16x0.50mm2 &gt; 16 x 0.50 mm2 &gt; 16 x 0.50 mm2 fixed flexible at short circuit (max. 5s) fixed flexible 450/750 V AC 2500 V AC 600/1000 V AC 3500 V AC –55 °C up to +155 °C –40 °C +280 °C 4 x cable–dia. 5 x cable–dia. Fire tests Flame propagation: Verical of a single cable Vertical of bunched cables EN 50265–2–1, IEC 60332–1 DIN EN 50266–2–5 Category D 50 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=51</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=51</link><title>HUBER+SUHNER   Low Frequency Page 51</title><description>RADOX® 155 RADOX® 125, RADOX® 155, KDJ-11 51 Multi core cable – screened Extract from our delivery programme Cross section Construction nom. n x mm dia. 19 x 0.12 19 x 0.12 19 x 0.12 19 x 0.18 19 x 0.18 30 x 0.25 30 x 0.25 30 x 0.25 50 x 0.25 50 x 0.25 Conductor dia. max. mm 0.61 0.61 0.61 0.9 0.9 1.61 1.61 1.61 2.06 2.06 R20 IEC 60228 max.Ω/km 88.5 88.5 88.5 40.1 40.1 13.3 13.3 13.3 8.6 8.6 Core dia. mm 1.45 ± 0.05 1.45 ± 0.05 1.45 ± 0.05 1.71 ± 0.10 1.71 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 2.73 ± 0.10 3.5 ± 0.10 3.5 ± 0.10 Screen dia. mm 3.35 5.07 11.2 5.55 9.0 6.6 11.9 18.0 14.5 15.1 Cable dia. mm 5.1 ± 0.3 6.95 ± 0.15 14.0 ± 0.4 7.6 ± 0.15 11.6 ± 0.4 8.7 ± 0.3 14.7 ± 0.4 22.0 ± 0.5 17.9 ± 0.5 18.6 ± 0.5 Weight nom. kg/100 m 3.43 6.71 27.7 7.62 20.3 11.6 33.2 74.1 49.8 51.8 n x mm2 2 x 0.25 6 x 0.25 4x2x0.25 4 x 0.5 16 x 0.5 3 G 1.5 10 G 1.5 26 G 1.5 8 G 2.5 9 G 2.5 Other cross sections on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=52</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=52</link><title>HUBER+SUHNER   Low Frequency Page 52</title><description>52 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=53</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=53</link><title>HUBER+SUHNER   Low Frequency Page 53</title><description>RADOX® UL/CSA Flexible single cores, multi core cables and wires UL recognised RADOX® UL 1385/CSA AWM I A/B flexible single core, 600 V RADOX® UL 3266/CSA AWM I A/B flexible single core, 300 V RADOX® UL 3271/CSA AWM I A/B flexible single core, 600 V RADOX® UL 3289/CSA CL 1503 flexible single core, 600 V RADOX® UL 3289/CSA CL 1503 single core solid wire, 600 V RADOX® UL 4486/CSA AWM I/II A/B multi core cables, 300 V RADOX® UL 4486/CSA AWM I/II A/B multi core cables, screened, 300 V RADOX® UL 4486/CSA AWM I/II A/B multi core cables, 600 V RADOX® UL 4486/CSA AWM I/II A/B multi core cables, screened, 600 V 52 54 56 58 60 62 64 66 68 RADOX® UL/CSA All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS). HUBER+SUHNER 53</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=54</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=54</link><title>HUBER+SUHNER   Low Frequency Page 54</title><description>RADOX® UL1385 / CSA AWM I A/B Flexible single core       • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high abration reistance • highly resistant to hydrolysis • resistant to impregnation resins and varnishes • easy to process • soldering resistant insulation • flexible Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable Conductor   Insulation 1  Insulation 2 Core colours Technical data Voltage rating Operating temperature Min. temperature Min. bending radius Approvals UL AWM 1385 CSA AWM I A/B stranded tin plated copper, acc. to EN 60228, class 5 electron beam crosslinked polyalcen electron beam crosslinked polyvinilydenfluorid (PVDF) various, on request (UL temperature rating) 600 V AC +125 °C –65 °C 3 x core–dia. 125 °C, no voltage rating 125 °C, 300 V, FT1, FT2 54 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=55</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=55</link><title>HUBER+SUHNER   Low Frequency Page 55</title><description>RADOX® UL1385 / CSA AWM I A/B Flexible single core Extract from our delivery programme Cross section nom. AWG 28 26 24 22 20 18 16 mm2 0.09 0.15 0.25 0.38 0.60 0.93 1.25 Construction nom. n x mm dia. 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 Conductor dia. max. mm 040 0.51 0.61 0.77 0.99 1.23 1.40 R20 MIL–W–81044/12 max.Ω/km 239 150 94.2 59.4 36.7 23.2 15.8 Core dia. mm 0.77 ± 0.05 0.87 ± 0.05 1.02 ± 0.05 1.18 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 1.83 ± 0.05 Weight nom. kg/100 m 0.13 0.19 0.43 0.65 0.95 1.30 Various colours on request. HUBER+SUHNER 55 RADOX® UL/CSA 0.30</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=56</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=56</link><title>HUBER+SUHNER   Low Frequency Page 56</title><description>RADOX® UL 3266 / CSA AWM I A/B Flexible single core     • excellent high and low temperature and ozone resistance • weatherproof • high abrasion reistance • resistant to impregnation resins and varnishes • easy to process • soldering resistant • flexible Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable Conductor   Insulation Core colours Technical data Voltage rating Uo / U Test voltage Operating temperature Min. temperature Min. bending radius Approvals UL CSA stranded tin plated copper, acc. to EN 60228, class 5 RADOX® extruded and electron beam crosslinked polyolefin copolymer various, on request (UL temperature rating) 300 V AC 2000 V AC +125 °C –40 °C 3 x core–dia. Underwriters Laboratories Canadian Standards Association File no. E63322 Report no. 69581 AWM I A/B 125 °C 300 V The cables comply with the following standards: Appliance wiring material CSA C22.2 no. 210.2 Appliance wiring material UL 758 Style 3266 The cables pass the following fire tests: VerticalflamespreadFT2 L≤100mm Horizontal flame spread, Applicance-wire V≤25mm/Min. CSAC22.2no.0.3#4.11.2 UL1581#1090 56 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=57</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=57</link><title>HUBER+SUHNER   Low Frequency Page 57</title><description>RADOX® UL 3266 / CSA AWM I A/B Flexible single core Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 (16) 14 12 10 mm2 0.15 0.25 0.38 0.62 0.96 1.5 2.1 3.3 5.26 Construction n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.31 19 x 0.37 37 x 0.35 37 x 0.44 Conductor dia. max. mm 0.51 0.61 0.77 0.99 1.23 1.52 1.86 2.35 3.02 Core dia. mm 1.32 ± 0.05 1.45 ± 0.05 1.65 ± 0.10 1.85 ± 0.10 2.10 ± 0.10 2.41 ± 0.10 2.72 ± 0.10 3.21 ± 0.10 3.88 ± 0.10 Weight nom. kg/100 m 0.32 0.41 0.53 1.13 1.65 2.33 3.53 5.61 Various colours on request. HUBER+SUHNER 57 RADOX® UL/CSA 0.83</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=58</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=58</link><title>HUBER+SUHNER   Low Frequency Page 58</title><description>RADOX® UL 3271 / CSA AWM I A/B Flexible single core     • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high abrasion reistance • easy to process • soldering resistant • flexible Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable Conductor   Insulation Core colours Technical data Voltage rating Test voltage Operating temperature Max. conductor temperature Min. operating temperature stranded tin plated copper, acc. to EN 60228, class 5 RADOX® extruded and electron beam crosslinked polyolefin copolymer various, on request (UL/CSA temperature rating) at short circuit (max. 5s) flexing fixed 600 V AC 2500 V AC +125 °C +280 °C –65 °C –25 °C –40 °C Standards Applicance wiring material Applicance wiring material Approvals UL CSA CSA C22.2 no. 210.2 UL 758 AWM I A/B 125°C 600 V FT2 Style 3271 Underwriters Laboratories Canadian Standards Association File no. E63322 Certificate no.1418425 58 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=59</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=59</link><title>HUBER+SUHNER   Low Frequency Page 59</title><description>RADOX® UL 3271 / CSA AWM I A/B Flexible single core The cables pass the following fire tests: VerticalflamespreadFT1 ≥16mm2 Horizontal flame spread FT2 Verticalflamespread ≥16mm2 Horizontal flame spread, Appliance–wire Verticalflamespread,VW-1 ≥16mm2 L≤250mm,t≤60s L≤100mm 50&lt;L≤540mm V≤25mm/Min. L≤250mm,t≤60s CSAC22.2no.0.3#4.11.1 CSAC22.2no.0.3#4.11.2 EN60332-1-2,IEC60332–1-2 UL1581#1090 UL1581#1080 RADOX® UL/CSA Conductor Construction nom. n x mm dia. 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.31 19 x 0.37 37 x 0.35 37 x 0.44 80 x 0.40 119 x 0.40 182 x 0.40 266 x 0.40 378 x 0.40 348 x 0.50 444 x 0.50 551 x 0.50 722 x 0.50 dia. max. mm 0.61 0.77 0.99 1.23 1.52 1.86 2.35 3.02 4.3 5.4 6.7 7.9 9.4 11.5 13.0 15.1 17.0 R20 IEC 60228 max.Ω/km 84.2 52.1 31.8 20.2 12.9 8.8 5.53 3.34 1.91 1.22 0.795 0.554 0.385 0.271 0.206 0.164 0.132 Core dia. mm 2.22 ± 0.10 2.40 ± 0.10 2.60 ± 0.10 2.85 ± 0.10 3.20 ± 0.10 3.50 ± 0.10 4.0 ± 0.15 4.7 ± 0.15 6.4 ± 0.15 8.6 ± 0.2 9.9 ± 0.2 11.1 ± 0.2 13.7 ± 0.25 15.8 ± 0.25 17.4 ± 0.3 19.3 ± 0.3 22.2 ± 0.3 Weight nom. kg/100 m 0.72 0.92 1.2 1.6 2.1 2.9 4.2 6.4 12.1 18.8 26.8 36.4 54.3 72.3 95.5 116 150 Bending radius min. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. 59 Extract from our delivery programme Cross section nom. AWG 24 22 20 18 (16) 14 12 10 (8) (6) (4) (2) (1) (2/0) (3/0) (4/0) mm2 (0.25) (0.38) (0.62) (0.96) 1.5 (2.1) (3.3) (5.26) 10 16 25 35 50 70 95 120 150 Various colours on request. HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=60</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=60</link><title>HUBER+SUHNER   Low Frequency Page 60</title><description>RADOX® UL 3289/CSA CL 1503 Flexible single core     • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high abrasion resistance • easy to process • soldering resistant • flexible • resistant to impregnation resins and varnishes Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable Conductor   Insulation Core colours Technical data Voltage rating Test voltage Operating temperature Min. temperature Approvals UL CSA stranded tin plated copper, acc. to EN 60228, class 5 RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer various, on request (UL temperature rating) 600 V AC 2500 V AC +150 °C –55 °C Underwriters Laboratories Canadian Standards Association File no. E63322 Certificate no. 039507 60 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=61</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=61</link><title>HUBER+SUHNER   Low Frequency Page 61</title><description>RADOX® UL 3289/CSA CL 1503 Flexible single core Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 (16) 14 12 10 (8) (6) (4) (2) (1) (2/0) (3/0) (4/0) mm2 0.149 0.205 0.324 0.519 0.823 1.50 2.08 3.31 5.26 10 16 25 35 50 70 95 120 Conductor Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.31 19 x 0.37 37 x 0.34 37 x 0.43 80 x 0.40 119 x 0.40 182 x 0.40 266 x 0.40 378 x 0.40 348 x 0.50 444 x 0.50 551 x 0.50 dia. max. mm 0.51 0.61 0.79 0.99 1.23 1.55 1.86 2.35 3.02 3.94 5.4 6.7 7.9 9.4 11.5 12.9 14.8 Core dia. mm 2.13 ± 0.10 2.27 ± 0.10 2.40 ± 0.10 2.61 ± 0.10 2.85 ± 0.10 3.20 ± 0.10 3.50 ± 0.10 4.00 ± 0.15 4.68 ± 0.15 6.40 ± 0.15 8.90 ± 0.2 10.2 ± 0.2 11.4 ± 0.2 14.0± 0.25 16.1± 0.3 17.6± 0.3 19.3 ± 0.3 Weight nom. kg/100 m 0.55 0.66 0.79 1.1 1.5 2.1 2.7 4.0 6.1 11.7 18.4 25.8 36.5 54.3 71.3 93.6 113 Bending radius min. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 3 x dia. 4 x dia. 4 x dia. 4 x dia. 4 x dia. Various colours on request. HUBER+SUHNER 61 RADOX® UL/CSA 3 x dia.</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=62</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=62</link><title>HUBER+SUHNER   Low Frequency Page 62</title><description>RADOX® UL 3289 / CSA CL 1503 Single core solid wire     • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high abrasion resistance • easy to process • soldering resistant • resistant to impregnation resins and varnishes Application Protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. Composition of cable Conductor   Insulation Core colours Technical data Voltage rating Operating temperature Min. temperature Approvals UL CSA stranded tin plated copper, acc. to EN 60228, class 1 RADOX® 155 extruded and electron beam crosslinked polyolefin copolymer various, on request (UL temperature rating) 600 V AC +150 °C –55 °C Underwriters Laboratories Canadian Standards Association File no. E63322 Certificate no. 039507 62 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=63</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=63</link><title>HUBER+SUHNER   Low Frequency Page 63</title><description>RADOX® UL 3289 / CSA CL 1503 Single core solid wire Extract from our delivery programme Cross section nom. AWG 20 18 16 14 mm2 0.517 0.821 1.31 2.08 Conductor dia. max. mm 0.8 1.1 1.4 1.8 Core dia. mm 2.45 ± 0.10 2.70 ± 0.10 3.05 ± 0.10 3.45 ± 0.10 Weight nom. kg/100 m 1.0 1.4 2.1 3.1 Bending radius min. 3 x dia. 3 x dia. 3 x dia. 3 x dia. Various colours on request. HUBER+SUHNER 63 RADOX® UL/CSA</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=64</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=64</link><title>HUBER+SUHNER   Low Frequency Page 64</title><description>RADOX® UL4486 / CSA AWM I/II A/B Multi core cable – 300 V • excellent high and low temperature and ozone resistance • weatherproof • easy to strip and process • flame retardant • in case of fire no corrosive gases and low smoke emission • flexible      Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Cores: Conductor Insulation Core colours  Fillers (optional)  Sheath Colour Technical data Voltage rating Test voltage Operating temperature Max. conductor temperature Min. operating temperature Min. bending radius Standards Applicance wiring material Applicance wiring material stranded tin plated copper, acc. to EN 60228, class 5 RADOX® various, on request RADOX® RADOX® 125M grey (UL temperature rating) at short circuit (max. 5s) flexing fixed 300 V AC 2000 V AC +125 °C +280 °C –25 °C –40 °C 5 x cable–dia. CSA C22.2 no. 210.2 UL 758 AWM I/II A/B 125°C 300 V FT1 Style 4486 64 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=65</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=65</link><title>HUBER+SUHNER   Low Frequency Page 65</title><description>RADOX® UL4486 / CSA AWM I/II A/B Multi core cable – 300 V Fire tests Flame propagation: Vertical flame spread, single cable Horizontal flame propagation Vertical flame spread, single cable Vertical flame spread, bunched cables Flame propagation: Horizontal flame propagation of an applicance wire Vertical flame spread, single cable Vertical flame spread, single cable Approvals CSA Certificate UL File CSA C22.2 no. 0.3 cl. 4.11.1 CSA C22.2 no. 0.3 cl. 4.11.2 EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 FT1 FT2 Category C UL 1581 sec. 1090 UL 1581 sec. 1061 UL 1581 sec. 1080 VW–1 1241318 E63322 Extract from our delivery programme Cross section nom. n x(G) AWG 2 x 20 2 x 18 2 x 12 4 x 14 Conductor Construction nom. n x mm dia. 19 x 0.20 19 x 0.25 37 x 0.34 19 x 0.37 R20 IEC 60228 max.Ω/km 32.6 21.3 5.67 9.02 dia. nom. mm 1.85 2.10 3.21 2.72 Core Colours* BU,BN BU,BN BU,BN BU,BN,BK,GY Cable dia. nom. mm 5.5 ± 0.3 6.0 ± 0.3 8.3 ± 0.3 8.5 ± 0.3 * abbreviations for core colours see page 139 Other cross sections on request. HUBER+SUHNER 65 RADOX® UL/CSA</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=66</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=66</link><title>HUBER+SUHNER   Low Frequency Page 66</title><description>RADOX® UL4486 / CSA AWM I/II A/B Multi core cable – screened – 300 V      • excellent high and low temperature and ozone resistance • weatherproof • easy to strip and process • flame retardant • in case of fire no corrosive gases and low smoke emission • flexible    Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Cores: Conductor Insulation Core colours  Fillers (optional)  Screen  Separator  Sheath Colour Technical data Voltage rating Test voltage Operating temperature Max. conductor temperature Min. operating temperature Min. bending radius Standards Applicance wiring material Applicance wiring material stranded tin plated copper, acc. to EN 60228, class 5 RADOX® various, on request RADOX® tin plated copper braid plastic tape RADOX® 125M grey UL temperature rating at short circuit (max. 5s) flexing fixed 300 V AC 2000 V AC +125 °C +280 °C –25 °C –40 °C 5 x cable–dia. CSA C22.2 no. 210.2 UL 758 AWM I/II A/B 125°C 300 V FT1 Style 4486 66 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=67</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=67</link><title>HUBER+SUHNER   Low Frequency Page 67</title><description>RADOX® UL4486 / CSA AWM I/II A/B Multi core cable – screened – 300 V Fire tests Flame propagation: Vertical flame spread, single cable Horizontal flame spread, single cable Vertical flame spread, single cable Vertical flame spread, bunched cables Flame propagation: Horizontal flame propagation of an applicance wire Vertical flame spread, single cable Vertical flame spread, single cable Approvals CSA Certificate UL File CSA C22.2 no. 0.3 cl. 4.11.1 CSA C22.2 no. 0.3 cl. 4.11.2 EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 FT1 FT2 Category C UL 1581 sec. 1090 UL 1581 sec. 1061 UL 1581 sec. 1080 VW–1 1241318 E63322 Extract from our delivery programme Cross section nom. n x(G) AWG 2 x 18 2 x 14 3 G 20 3 x 14 4 G 18 4 x 12 Conductor Construc. nom. n x mm dia. 19 x 0.25 19 x 0.37 19 x 0.20 19 x 0.37 19 x 0.25 37 x 0.34 R20 IEC 60228 max.Ω/km 21.3 9.02 32.6 9.02 21.3 5.67 dia. nom. mm 2.10 2.72 1.85 2.72 2.10 3.21 Core Colours* BU,BN BU,BN BU,BN,GNYE BU, BN,BK BU,BN,BK,GNYE BU,BN,BK,GY Screen dia. nom. mm 4.6 6.0 4.5 6.5 5.7 8.8 Cable dia. nom. mm 6.6 ± 0.3 7.9 ± 0.3 6.4 ± 0.3 8.3 ± 0.3 7.6 ± 0.3 10.7 ± 0.4 * abbreviations for core colours see page 140 Other cross sections on request HUBER+SUHNER 67 RADOX® UL/CSA</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=68</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=68</link><title>HUBER+SUHNER   Low Frequency Page 68</title><description>RADOX® UL4486 / CSA AWM I/II A/B Multi core cable – 600 V      • excellent high and low temperature and ozone resistance • weatherproof • easy to strip and process • flame retardant • in case of fire no corrosive gases and low smoke emission • flexible Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Cores: Conductor Insulation Core colours  Fillers (optional)  Sheath Colour Technical data Voltage rating Test voltage Max. conductor temperature stranded tin plated copper, acc. to EN 60228, class 5 RADOX® diverse, on request RADOX® RADOX® 125M grey Min. operating temperature Min. bending radius Standards Applicance wiring material Applicance wiring material in continuous operation 10'000 h 3'000 h at short circuit (max. 5s) flexing fixed 600 V AC 2500 V AC +125 °C +130 °C +145 °C + 280 °C –25 °C –40 °C 5 x cable–dia. CSA C22.2 no. 210.2 UL 758 AWM I/II A/B 125°C 600 V FT1 Style 4486 68 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=69</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=69</link><title>HUBER+SUHNER   Low Frequency Page 69</title><description>RADOX® UL4486 / CSA AWM I/II A/B Multi core cable – 600 V Fire tests Flame propagation: Vertical flame spread, single cable Horizontal flame spread, single cable Vertical flame spread, single cable Vertical flame spread, bunched cables Flame propagation: Horizontal flame propagation of an applicance wire Vertical flame spread, single cable Vertical flame spread, single cable Approvals CSA Certificate UL File CSA C22.2 no. 0.3 cl. 4.11.1 CSA C22.2 no. 0.3 cl. 4.11.2 EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 FT1 FT2 Category C UL 1581 sec. 1090 UL 1581 sec. 1061 UL 1581 sec. 1080 VW–1 1241318 E63322 Extract from our delivery programme Cross section nom. n x (G) AWG 1 x 1 2 x 20 3 G 20 3 x 14 4 G 12 Conductor Construction nom. n x mm dia. 378 x 0.40 19 x 0.20 19 x 0.20 19 x 0.37 37 x 0.34 R20 IEC 60228 max.Ω/km 0.385 32.6 32.6 9.02 5.67 dia. nom. mm 13.7 2.60 2.60 3.50 4.00 Core Colours* BK BU,BN BU,BN,GNYE BU,BN,BK BU,BN,BK,GNYE Cable dia. nom. mm 16.5 ± 0.3 7.0 ± 0.3 7.45 ± 0.3 9.4 ± 0.3 11.7 ± 0.4 * abbreviations for core colours see page 140 Other cross sections on request. HUBER+SUHNER 69 RADOX® UL/CSA</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=70</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=70</link><title>HUBER+SUHNER   Low Frequency Page 70</title><description>RADOX® UL 4486/CSA AWM I/II A/B Multi core cable – screened — 600 V • excellent high and low temperature and ozone resistance • weatherproof • easy to strip and process • flame retardant • in case of fire no corrosive gases and low smoke emission • flexible          Application Permanent installation indoor and outdoor for the connection of fixed and loose parts. Composition of cable  Cores: Conductor Insulation Core colours  Fillers (optional)  Screen  Separator  Sheath Colour Technical data Voltage rating Test voltage Operating temperature Max. conductor temperature Min. operating temperature Min. bending radius Standards Applicance wiring material Applicance wiring material stranded tin plated copper, acc. to EN 60228, class 5 RADOX® various, on request RADOX® tin plated copper braid plastic tape RADOX® 125M grey (UL temperature rating) at short circuit (max. 5s) flexing fixed 600 V AC 2500 V AC +125 °C +280 °C –25 °C –40 °C 5 x cable–dia. CSA C22.2 no. 210.2 UL 758 AWM I/II A/B 125°C 600 V FT1 Style 4486 70 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=71</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=71</link><title>HUBER+SUHNER   Low Frequency Page 71</title><description>RADOX® UL 4486/CSA AWM I/II A/B Multi core cable – screened — 600 V Fire tests Flame propagation: Vertical flame spread, single cable Horizontal flame spread, single cable Vertical flame spread, single cable Vertical flame spread, bunched cables Flame propagation: Horizontal flame propagation of an applicance wire Vertical flame spread, single cable Vertical flame spread, single cable Approvals CSA Certificate UL File CSA C22.2 no. 0.3 cl. 4.11.1 CSA C22.2 no. 0.3 cl. 4.11.2 EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 FT1 FT2 Category C UL 1581 sec. 1090 UL 1581 sec. 1061 UL 1581 sec. 1080 VW–1 1241318 E63322 Extract from our delivery programme Cross section nom. n x (G) AWG 1 G 2* 1 x 3/0 2 x 14 3 G 20 3x8 4 x 22 4 G 16 4x6 5 x 18 12 G 14 Conductor Construct. nom. n x mm dia. 266 x 0.40 444 x 0.50 19 x 0.37 19 x 0.20 80 x 0.40 19 x 0.16 19 x 0.31 119 x 0.40 19 x 0.25 19 x 0.37 R20 IEC 60228 max.Ω/km 0.554 0.206 9.02 32.6 1.96 54.7 13.7 1.25 21.3 9.02 dia. nom. mm 11.1 17.3 3.50 2.60 6.40 2.4 3.10 8.60 2.85 3.50 Core Colours* GNYE BK BU, BN BU, BN, GNYE BK, YE num. WH num. BU, BN, BK, GNYE BU, BN, BK, GY BU, BN, BK, GY, BK BK, YE num., GNYE Screen dia. nom. mm 12.2 18.4 7.7 6.2 15.1 6.6 8.7 22.5 8.7 15.7 Cable dia. mm 14.1 ± 0.3 22.8 ± 0.3 9.6 ± 0.3 8.1 ± 0.3 18.2 ± 0.5 8.5 ± 0.3 10.7 ± 0.4 27.3 ± 0.6 10.7 ± 0.4 18.8 ± 0.5 * abbreviations for core colours see page 140 Other cross sections on request. HUBER+SUHNER 71 RADOX® UL/CSA</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=72</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=72</link><title>HUBER+SUHNER   Low Frequency Page 72</title><description>72 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=73</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=73</link><title>HUBER+SUHNER   Low Frequency Page 73</title><description>RADOX® System cables Single cores, single core cables, multi core cables and wires MA 12 A1 system element MA 12 E1, single core, screened MA 12 E2, screened pair MA 14 A1, single core MIL 5932 A1, single core (MIL 22759/32) 72 74 76 78 80 ® system RADOX® system cables RADOX cables MIL 5932 E1, single core, screened (MIL 22759/32) 82 MIL 5932/34 E2, E3, E4, screened pair, (MIL 22759/32) MIL 4412 A1, single core (MIL-W-81044/12) MIL 4412 E1, single core, screened (MIL-W-81044/12) MIL 4412 E2, screened pair (MIL-W-81044/12) VG single cores and cables RADOX® MFH, power and signal cables, multi core, screend and unscreend Hybrid cables 84 86 88 90 92 – 101 102 104 – 105 All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS). HUBER+SUHNER 73</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=74</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=74</link><title>HUBER+SUHNER   Low Frequency Page 74</title><description>MA 12 A1 System element     • halogen free • easy to process • high media and abrasion resistance • excellent resistance to high and low temperatures • flame retardant • high resistance to heat pressure Application Dry and protected, flexible and fixed installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor  Insulation Colours Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable Content of halogen acid gas stranded tin plated copper, acc. to MIL-W-29606 TCC Multi A–12, extruded polyster various, on request 600 V AC 3000 V AC –40 °C up to +120 °C 3 x core–dia. EN 50265–2–1, IEC 60332–1 EN 50267–2–1, IEC 60754–1 0 mg/g 74 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=75</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=75</link><title>HUBER+SUHNER   Low Frequency Page 75</title><description>MA 12 A1 System element Extract from our delivery programme Cross section nom. AWG 28 26 24 22 20 18 16 14 12 10 mm2 0.09 0.15 0.25 0.38 0.60 0.93 1.25 1.93 2.97 4.74 Construction nom. n x mm dia. 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 19 x 0.35 37 x 0.32 37 x 0.40 Conductor dia. max. mm 0.40 0.51 0.61 0.79 0.99 1.23 1.40 1.64 2.24 2.77 R20 MIL–W–81044/12 max.Ω/km 225.0 135.5 85.96 53.15 32.42 20.44 15.78 10.04 6.63 4.14 Core dia. mm 0.76 ± 0.05 0.87 ± 0.05 1.02 ± 0.05 1.19 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 1.83 ± 0.05 2.27 ± 0.08 2.75 ± 0.08 3.53 ± 0.1 Weight nom. kg/100 m 0.10 0.17 0.30 0.43 0.65 0.95 1.30 1.86 2.87 4.76 Various colours on request. HUBER+SUHNER 75 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=76</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=76</link><title>HUBER+SUHNER   Low Frequency Page 76</title><description>MA 12 E1 Single core – screened • halogen free • easy to process • high media and abrasion resistance • excellent resistance to high and low temperatures • flame retardant • high resistance to heat pressure • constructions and dimensions acc. to NEMA WC 27500         Application Dry and protected, flexible and fixed installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor  Insulation Core colours  EMV screen  Sheath Colour Technical data Voltage rating Test voltage Temperature range Transferimpedanceupto30MHz Min. bending radius Fire tests Flame propagation: Vertical of a single cable Content of halogen acid gas stranded tin plated copper, acc. to MIL-W-29606 TCC Multi A–12, extruded polyster white or blue optimised Multi A–12 polyester white 600 V AC 2500 V AC –40 °C up to +120 °C 250mΩ/m 3 x core–dia. EN 50265–2–1, IEC 60332–1 EN 50267–2–1, IEC 60754–1 0 mg/g 76 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=77</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=77</link><title>HUBER+SUHNER   Low Frequency Page 77</title><description>MA 12 E1 Single core – screened Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 16 14 12 mm2 0.15 0.25 0.38 0.60 0.93 1.25 1.93 2.97 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 37 x 0.26 37 x 0.32 Conductor max. dia. mm 0.51 0.61 0.79 0.99 1.23 1.40 1.80 2.24 R20 IEC 60228 max.Ω/km 135.5 85.96 53.15 32.42 20.44 15.78 10.04 6.63 dia. mm 0.87 ± 0.05 1.02 ± 0.05 1.19 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 1.83 ± 0.05 2.27 ± 0.08 2.75 ± 0.08 Core Outer–dia. mm 1.65 ± 0.1 1.90 ± 0.1 2.05 ± 0.1 2.30 ± 0.1 2.50 ± 0.1 2.70 ± 0.1 3.15 ± 0.1 3.60 ± 0.1 Weight nom. kg/100 m 0.17 0.30 0.43 0.65 0.95 1.30 1.97 2.87 HUBER+SUHNER 77 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=78</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=78</link><title>HUBER+SUHNER   Low Frequency Page 78</title><description>MA 12 E2 Screend pair     • halogen free • easy to process • high media and abrasion resistance • excellent resistance to high and low temperatures • flame retardant • high resistance to heat pressure • constructions and dimensions acc. to NEMA WC 27500     Application Dry and protected, flexible and fixed installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor  Insulation Core colours  EMV screen  Sheath Colour Technical data Voltage rating Test voltage Temperature range Transferimpedanceupto30MHz Min. bending radius Fire tests Flame propagation: Vertical of a single cable Content of halogen acid gas stranded tin plated copper, acc. to MIL-W-29606 TCC Multi A–12, extruded polyester white/blue, white/red, white/black, white/green two cores twisted optimised Multi A–12 polyester white 600 V AC 2500 V AC –40 °C up to +120 °C 250mΩ/m 3 x core–dia. EN 50265–2–1, IEC 60332–1 EN 50267–2–1, IEC 60754–1 0 mg/g 78 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=79</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=79</link><title>HUBER+SUHNER   Low Frequency Page 79</title><description>MA 12 E2 Screend pair Extract from our delivery programme Cross section nom. AWG 2 x 26 2 x 24 2 x 22 2 x 20 2 x 18 mm2 0.15 0.25 0.38 0.60 0.93 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 Conductor dia. max. mm 0.51 0.61 0.79 0.99 1.23 R20 IEC 60228 max.Ω/km 138.5 87.9 54.4 33.2 20.9 dia. mm 0.87 ± 0.05 1.02 ± 0.05 1.19 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 Core Outer–dia. mm 2.60 ± 0.1 2.85 ± 0.1 3.15 ± 0.1 3.60 ± 0.1 4.30 ± 0.1 Weight nom. kg/100 m 0.94 1.33 1.71 2.14 3.38 HUBER+SUHNER 79 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=80</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=80</link><title>HUBER+SUHNER   Low Frequency Page 80</title><description>MA 14 A1 Single core       • halogen free • easy to process • high media and abrasion resistance • excellent resistance to high and low temperatures • flame retardant • high resistance to heat pressure • constructions and dimensions acc. to MIL–W–81044 Application Protected, flexible and fixed installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor Insulation 1  Insulation 2  Colours Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable Content of halogen acid gas stranded tin plated copper high tech polymer aromatic polymer various, on request 600 V AC 2500 V AC –40 °C up to +140 °C 3 x core–dia. EN 50265–2–1, IEC 60332–1 EN 50267–2–1, IEC 60754–1 0 mg/g 80 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=81</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=81</link><title>HUBER+SUHNER   Low Frequency Page 81</title><description>MA 14 A1 Single core Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 16 14 12 –– –– –– –– –– mm2 (0.15) (0.25) (0.38) (0.60) (0.93) (1.25) (1.96) (2.97) 0.50 0.75 1.00 1.50 2.50 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 37 x 0.26 37 x 0.32 19 x 0.18 19 x 0.22 19 x 0.25 37 x 0.22 37 x 0.29 Conductor dia. max. mm 0.51 0.61 0.77 0.99 1.23 1.40 1.74 2.22 0.91 1.12 1.23 1.57 1.97 R20 MIL–W–81044/12 max.Ω/km 135.5 85.96 53.15 32.42 20.44 15.78 10.8 6.63 40.1 26.7 20.0 13.7 8.21 Core dia. mm 0.87 ± 0.02 1.02 ± 0.02 1.18 ± 0.02 1.39 ± 0.02 1.67 ± 0.03 1.83 ± 0.03 2.29 ± 0.04 2.78 ± 0.04 1.30 ± 0.02 1.52 ± 0.03 1.67 ± 0.03 2.04 ± 0.04 2.54 ± 0.04 Weight nom. kg/100 m 0.18 0.30 0.43 0.65 0.95 1.30 1.97 2.87 0.53 0.79 1.48 2.36 HUBER+SUHNER 81 RADOX® system cables 0.94</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=82</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=82</link><title>HUBER+SUHNER   Low Frequency Page 82</title><description>MIL 5932 A1 Single core     • easy to process • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high media and abrasion resistance • constructions and dimensions acc. to MIL–W–22759 Application Protected, flexible and fixed installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable Conductor  Insulation  Colours Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable stranded tin plated copper, acc. to MIL-W-29606 TCC ETFE–X, extruded fluorcarbon, electron beam crosslinked various, on request 600 V AC 2500 V AC –65 °C up to +150 °C 3 x core–dia. EN 50265–2–1, IEC 60332–1 82 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=83</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=83</link><title>HUBER+SUHNER   Low Frequency Page 83</title><description>MIL 5932 A1 Single core Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 16 14 12 mm2 0.15 0.25 0.38 0.60 0.93 1.25 1.93 2.97 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.28 19 x 0.36 37 x 0.32 Conductor dia. max. mm 0.51 0.61 0.77 0.99 1.23 1.40 1.73 2.22 R20 MIL–W–81044/12 max.Ω/km 133 84.2 52.1 31.8 20.2 15.6 10.04 6.63 Core dia. mm 0.81 ± 0.05 0.94 ± 0.05 1.09 ± 0.05 1.27 ± 0.05 1.52 ± 0.05 1.73 ± 0.05 2.16 ± 0.08 2.62 ± 0.08 Weight nom. kg/100 m 0.21 0.30 0.42 0.64 0.97 1.25 1.95 2.95 Other cross sections on request. RADOX® system cables HUBER+SUHNER 83</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=84</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=84</link><title>HUBER+SUHNER   Low Frequency Page 84</title><description>MIL 5932 E1 Single core – screened     • easy to process • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure • high media and abrasion resistance • constructions and dimensions acc. to MIL–W–22759     Application Protected, flexible and fixed installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable Conductor  Insulation  Core colours EMV screen  Sheath  Colour Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable Content of halogen acid gas stranded tin plated copper, acc. to MIL-W-29606 TCC ETFE–X, extruded fluorcarbon, electron beam crosslinked various, on request optimised ETFE–X, extruded fluorcarbon, electron beam crosslinked white 600 V AC 2500 V AC –55 °C up to +150 °C 3 x core–dia. EN 50265–2–1, IEC 60332–1 EN 50267–2–1, IEC 60754–1 0 mg/g 84 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=85</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=85</link><title>HUBER+SUHNER   Low Frequency Page 85</title><description>MIL 5932 E1 Single core – screened Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 16 mm2 0.15 0.25 0.38 0.60 0.93 1.25 nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.28 Conductor dia. max. mm 0.50 0.60 0.76 0.96 1.20 1.36 R20 IEC 60228 max.Ω/km 133 84.2 52.1 31.8 20.2 15.6 dia. mm 0.81 ± 0.05 0.94 ± 0.05 1.09 ± 0.05 1.27 ± 0.05 1.52 ± 0.05 1.73 ± 0.05 Core Outer–dia. mm 1.64 ± 0.12 1.76 ± 0.12 1.90 ± 0.12 2.09 ± 0.15 2.35 ± 0.15 2.55 ± 0.15 Weight nom. kg/100 m 0.17 0.30 0.43 0.65 0.95 1.30 Other cross sections on request. HUBER+SUHNER 85 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=86</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=86</link><title>HUBER+SUHNER   Low Frequency Page 86</title><description>MIL 5932/34 E2 Screened pairs     • easy to process • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • high resistance to heat pressure  Figure shows MIL 5932 E2   Application For applications inside electrical equipment and for control and supply cables. Composition of cable  Conductor Insulation  Core colours EMV screen  Sheath  Colour Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable stranded tin plated copper, acc. to MIL-W-29606 TCC ETFE–X, extruded fluorcarbon, electron beam crosslinked various, on request two cores twisted optimised ETFE–X, extruded fluorcarbon, electron beam crosslinked white 600 V AC 2500 V AC –55 °C up to +150 °C 3 x core–dia. EN 50265–2–1, IEC 60332–1 86 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=87</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=87</link><title>HUBER+SUHNER   Low Frequency Page 87</title><description>MIL 5932/34 E2 Screened pairs Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 16 14 mm2 0.15 0.25 0.38 0.60 0.96 1.2 1.94 Construction nom. n x mm dia. 19 x 0.10 19 x 0.12 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 19 x 0.36 Conductor dia. max. mm 0.51 0.61 0.77 0.99 1.23 1.40 1.68 R20 IEC 60228 max.Ω/km 140.0 88.5 54.7 33.4 21.1 14.9 10.3 dia. mm 0.81 ± 0.05 0.94 ± 0.05 1.09 ± 0.05 1.27 ± 0.05 1.52 ± 0.05 1.73 ± 0.05 2.15 ± 0.05 Core Outer–dia. mm 2.45 ± 0.12 2.70 ± 0.12 2.98 ± 0.12 3.36 ± 0.12 3.87 ± 0.12 4.34 ± 0.13 5.20 ± 0.13 Weight nom. kg/100 m 1.1 1.3 1.7 2.2 3.0 3.7 5.4 HUBER+SUHNER 87 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=88</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=88</link><title>HUBER+SUHNER   Low Frequency Page 88</title><description>MIL 4412 A1 Single core       • flame retardant • easy to process • high media and abrasion resistance • excellent high and low temperature and ozone resistance • weatherproof • constructions and dimensions acc. to MIL–W–81044 Application For protected installations inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor Insulation 1  Insulation 2  Core colours Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable Approval Department of the Navy stranded tin plated copper, acc. to MIL-W-29606 TCC polyalkene, extruded polyalkene, electron beam crosslinked XLPVDF, extruded polyvinylidenefluoride, electron beam crosslinked various, on request 600 V AC 2500 V AC –65 °C up to +150 °C 3 x core–dia. EN 50265–2–1, IEC 60332–1 Ref. 0812 101-AD 3 88 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=89</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=89</link><title>HUBER+SUHNER   Low Frequency Page 89</title><description>MIL 4412 A1 Single core Extract from our delivery programme Cross section nom. AWG 28 26 24 22 20 18 16 14 12 mm2 0.09 0.15 0.25 0.38 0.60 0.93 1.25 1.93 2.97 Construction nom. n x mm dia. 7 x 0.13 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 19 x 0.36 37 x 0.32 Conductor dia. max. mm 0.40 0.51 0.61 0.77 0.99 1.23 1.40 1.68 2.22 R20 MIL–W–81044/12 max.Ω/km 225.1 135.5 85.96 53.15 32.42 20.44 15.78 10.04 6.63 Core dia. mm 0.76 ± 0.05 0.87 ± 0.05 1.02 ± 0.05 1.18 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 1.83 ± 0.05 2.27 ± 0.08 2.75 ± 0.08 Weight nom. kg/100 m 0.13 0.19 0.30 0.43 0.65 0.95 1.30 1.97 2.87 HUBER+SUHNER 89 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=90</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=90</link><title>HUBER+SUHNER   Low Frequency Page 90</title><description>MIL 4412 E1 Single core – screened      • flame retardant • easy to process • high media and abrasion resistance • excellent high and low temperature and ozone resistance • weatherproof • constructions and dimensions acc. to NEMA WC 27500      Application For protected installations inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor Insulation 1  Insulation 2  Core colours  EMV screen  Sheath Colour Technical data Voltage rating Test voltage Temperature range Transferimpedanceupto30MHz Min. bending radius Fire tests Flame propagation: Vertical of a single cable stranded tin plated copper, acc. to MIL-W-29606 TCC polyalkene, extruded polyalkene, electron beam crosslinked XLPVDF, extruded polyvinylidenefluoride, electron beam crosslinked various, on request optimised XLPVDF, electron beam crosslinked white 600 V AC 2500 V AC –55 °C up to +150 °C 250mΩ/m 3 x core–dia. EN 50265–2–1, IEC 60332–1 90 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=91</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=91</link><title>HUBER+SUHNER   Low Frequency Page 91</title><description>MIL 4412 E1 Single core – screened Extract from our delivery programme Cross section nom. AWG 26 24 22 20 18 16 14 12 mm2 0.15 0.25 0.38 0.60 0.93 1.25 1.93 2.97 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 19 x 0.36 37 x 0.32 Conductor dia. max. mm 0.51 0.61 0.79 0.99 1.23 1.40 1.80 2.24 R20 IEC 60228 max.Ω/km 135.5 85.96 53.15 32.42 20.44 15.78 10.04 6.63 dia. mm 0.87 ± 0.05 1.02 ± 0.05 1.19 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 1.83 ± 0.05 2.27 ± 0.08 2.75 ± 0.08 Core Outer–dia. mm 1.65 ± 0.1 1.90 ± 0.1 2.05 ± 0.1 2.30 ± 0.1 2.50 ± 0.1 2.70 ± 0.1 3.15 ± 0.1 3.60 ± 0.1 Weight nom. kg/100 m 0.17 0.30 0.43 0.65 0.95 1.30 1.97 2.87 HUBER+SUHNER 91 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=92</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=92</link><title>HUBER+SUHNER   Low Frequency Page 92</title><description>MIL 4412 E2 Multicore – screened      • easy to process • high resistance to heat pressure • high chemical and abrasion resistance • excellent high and low temperature and ozone resistance • weatherproof • flame retardant • constructions and dimensions acc. to NEMA WC 27500      Application For protected installation inside electrical equipment, elements of control and supply cables and system cables. Composition of cable  Conductor Insulation 1  Insulation 2  Core colours  EMVscreen  Sheath Colour Technical data Voltage rating Test voltage Temperature range Transferimpedanceupto30MHz Min. bending radius Fire tests Flame propagation: Vertical of a single cable stranded tin plated copper, acc. to MIL-W-29606 TCC polyalkene, extruded polyalkene, electron beam crosslinked XLPVDF, extruded polyvinylidenefluoride, electron beam crosslinked various, on request two cores twisted optimised XLPVDF, electron beam crosslinked white 600 V AC 2500 V AC –55 °C up to +150 °C 200mΩ/m 3 x core–dia. EN 50265–2–1, IEC 60332–1 92 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=93</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=93</link><title>HUBER+SUHNER   Low Frequency Page 93</title><description>MIL 4412 E2 Multicore – screened Extract from our delivery programme Cross section nom. AWG 2 x 26 2 x 24 2 x 22 2 x 20 2 x 18 mm2 0.15 0.25 0.38 0.60 0.93 Construction nom. n x mm dia. 19 x 0.10 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 Conductor dia. max. mm 0.51 0.61 0.79 0.99 1.23 R20 IEC 60228 max.Ω/km 138.5 87.9 54.4 33.2 20.9 dia. mm 0.87 ± 0.05 1.02 ± 0.05 1.19 ± 0.05 1.40 ± 0.05 1.66 ± 0.05 Core Outer–dia. mm 2.60 ± 0.1 2.85 ± 0.1 3.15 ± 0.1 3.60 ± 0.1 4.30 ± 0.1 Weight nom. kg/100 m 0.94 1.33 1.71 2.14 3.38 HUBER+SUHNER 93 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=94</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=94</link><title>HUBER+SUHNER   Low Frequency Page 94</title><description>VG 95218 T020 Type A and type G • temperature range –55 °C up to +150 °C • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • small outer diameter, low weight • flame retardant, self-extinguishing • easy to strip • easy to process • soldering resistant Application Wiring of electrical/electronic systems, for system cables in defence, aircraft, sensor systems, instrumentation, motors, transformers and industrial automation. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Approvals BA für Wehrtechnik und Beschaffung VDE type A type G type A type G 600 V AC 1 VG 95218/BWB specification 0.25 – 16 mm2 1.5 – 95 mm2 ETFE polyolefin–X Certificate of approval no. U3.h/10015 Certificate no. 9430 94 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=95</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=95</link><title>HUBER+SUHNER   Low Frequency Page 95</title><description>VG 95218 T020 Type E and type F • temperature range –55 °C up to +105 °C • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • small outer diameter, low weight • flame retardant, self-extinguishing • easy to strip • easy to process • soldering resistant • halogen free Cross section from to Insulation material Voltage rating Number of conductors Conductor class Approvals BA für Wehrtechnik und Beschaffung VDE type E type F type E type F 600 V 1 VG 95218/BWB specification 0.15 – 3 mm2 1.5 – 95 mm2 high tech polymer/aromatic p. polyolefin–X Certificate of approval no. U3.h/10015 Certificate no. 106443 and 134557 HUBER+SUHNER 95 RADOX® system cables Application Wiring of electrical/electronic systems, for system cables in defence, aircraft, sensor systems, instrumentation, motors, transformers and industrial automation.</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=96</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=96</link><title>HUBER+SUHNER   Low Frequency Page 96</title><description>VG 95218 T021 Type C and type E • type C acc. to T020 type E • type E acc. to T020 type A Application Wiring of electrical/electronic systems, for system cables in defence, aircraft, sensor systems, instrumentation, motors, transformers and industrial automation. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Approvals BA für Wehrtechnik und Beschaffung VDE 0.15 – 3 mm2 high tech polymer/aromatic p. ETFE white type C type E 600 V 2–4 VG 95218/BWB specification Certificate of approval no. U3.h/10016 Certificate no. 9431 and 106444 96 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=97</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=97</link><title>HUBER+SUHNER   Low Frequency Page 97</title><description>VG 95218 T022 Type C screened • temperature range –55 °C up to +150 °C • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • small outer diameter, low weight • flame retardant, self-extinguishing • easy to strip • easy to process • soldering resistant Application Wiring of electrical/electronic systems, for system cables in defence, aircraft, sensor systems, instrumentation, motors, transformers and industrial automation. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Screen Jacket Approvals BA für Wehrtechnik und Beschaffung VDE 0.25 – 2.5 mm2 ETFE white 600 V 1 VG 95218/BWB specification CU tinned, optimized ETFE white RADOX® system cables 97 Certificate of approval no. U3.h/10017 Certificate no. 9432 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=98</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=98</link><title>HUBER+SUHNER   Low Frequency Page 98</title><description>VG 95218 T023 Type F, multi core screened • temperature range –55 °C up to +150 °C • resistant to oils, fuels, lubricants, alkaline solutions and acids • notch and abrasion resistant • small outer diameter, low weight • flame retardant, self-extinguishing • easy to strip • easy to process • soldering resistant Application Wiring of electrical/electronic systems, for system cables in defence, aircraft, sensor systems, instrumentation, motors, transformers and industrial automation. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Screen Jacket Approvals BA für Wehrtechnik und Beschaffung VDE 0.25 – 3.0 mm2 ETFE 600 V 2–7 VG 95218/BWB specification CU tinned, optimized ETFE white Certificate of approval no. U3.h/10018 Certificate no. 9433 98 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=99</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=99</link><title>HUBER+SUHNER   Low Frequency Page 99</title><description>VG 95218 T024 Type K • temperature range –40 °C up to +150 °C • weatherproof • resistant to mineral oils and fuels • high abrasion resistance • flame resistant, self-extinguishing • non-melting • flexible • system compatibility with heat shrink parts according to VG 95343 part 14 Application System cables in defence, aircraft, sensor systems and instrumentation. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Jacket Approvals BA für Wehrtechnik und Beschaffung VDE 1.5 – 95 mm2 RADOX® 600 V 1 VG 95218/BWB specification RADOX® elastomer S, black RADOX® system cables 99 Certificate of approval no. U48/05019 Certificate no. 40000936 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=100</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=100</link><title>HUBER+SUHNER   Low Frequency Page 100</title><description>VG 95218 T025 Type G, high flexible • temperature range –40 °C up to +150 °C • weatherproof • resistant to mineral oils and fuels • high abrasion resistance • flame resistant, self-extinguishing • non-melting • flexible • system compatibility with heat shrink parts according to VG 95343 part 14 Application System cables in defence, sensor systems, instrumentation and ground wires. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Approvals BA für Wehrtechnik und Beschaffung VDE 10 – 240 mm2 RADOX® elastomer S, black 600 V 1 VG 95218/BWB specification, plain Certificate of approval no. U48/06099 Certificate no. 40000952 100 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=101</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=101</link><title>HUBER+SUHNER   Low Frequency Page 101</title><description>VG 95218 T026 Type H, high flexible • temperature range –40 °C up to +150 °C • weatherproof • resistant to mineral oils and fuels • high abrasion resistance • flame resistant, self-extinguishing • non-melting • flexible • system compatibility with heat shrink parts according to VG 95343 part 14 Application Control and supply cables in fixed and moving systems of defence and sensor systems. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Screen Jacket Approvals BA für Wehrtechnik und Beschaffung VDE 25 – 240 mm2 RADOX® elastomer S, black 600 V 1 VG 95218/BWB specification, bare CU tinned, optimized RADOX® elastomer S, black RADOX® system cables 101 Certificate of approval no. U48/06100 Certificate no. 40000957 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=102</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=102</link><title>HUBER+SUHNER   Low Frequency Page 102</title><description>VG 95218 T027 Type B, multi core • temperature range –40 °C up to +150 °C • weatherproof • resistant to mineral oils and fuels • high abrasion resistance • flame resistant, self-extinguishing • non-melting • flexible • system compatibility with heat shrink parts according to VG 95343 part 14 Application Control and supply cables in fixed and moving systems of defence and sensor systems. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Jacket Approvals BA für Wehrtechnik und Beschaffung VDE 0.25 – 35 mm2 ETFE white 600 V 2 – 61 VG 95218/BWB specification RADOX® elastomer S, black Certificate of approval no. U48/08018 Certificate no. 40000959 102 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=103</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=103</link><title>HUBER+SUHNER   Low Frequency Page 103</title><description>VG 95218 T028 Type D and type A, multi core, screened • temperature range –40 °C up to +150 °C • weatherproof • resistant to mineral oils and fuels • high abrasion resistance • flame resistant, self-extinguishing • non-melting • flexible • system compatibility with heat shrink parts according to VG 95343 part 14 Application Control and supply cables in fixed and moving systems of defence and sensor systems. Cross section from to Insulation material Voltage rating Number of conductors Conductor class Screen Jacket Approvals BA für Wehrtechnik und Beschaffung VDE 0.25 – 13 mm2 ETFE white 600 V 2 – 104 VG 95218/BWB specification CU tinned, optimized (type A double screen) RADOX® elastomer S, black RADOX® system cables 103 Certificate of approval no. U3.h/10019 Certificate no. 9438 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=104</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=104</link><title>HUBER+SUHNER   Low Frequency Page 104</title><description>RADOX® MFH MFH–S MFH–P Signal cable screened and unscreened Power cable       • ozone, hydrolysis, chemical resistant • weatherproof • easy to process • leight weight • wide operating temperature range • halogen free • flame retardant     Application For fixed installations in dry, damp or wet locations, inside and outside of ships, industrial equipment, defence equipment, buses, other vehicles and railway rolling stock. Composition of cable  Centre (if necessary)  Cores 2 x 0.75 mm2 Conductor Dual wall insulation Core colours Fillers (optional)   EMVscreening Separator  Sheath  Colour Technical data Voltage rating Uo/U Test voltage Temperature range Min.bendingradius RADOX® filler stranded tin plated copper, acc. to EN 60228, class 5 type Multi A 14 A2–0.75 high tech polymer see table two cores twisted RADOX® optimisedtinplatedcopperbraid,opticalcoverage:≥85% textile yarn RADOX® elastomer S FH black fixed ≤12mm ≥12mm flexing &gt;12 mm &gt;12 mm 600 / 1000 V AC 3500 V AC –25 °C up to +120 °C 3xcable–dia. 4xcable–dia. 5 x cable–dia. 6 x cable–dia. Fire tests Flame propagation: Vertial of a single cable Content of halogen acid gas EN 50265–2–1, IEC 60332–1 EN 50267–2–1, IEC 60754–1 0 mg/g 104 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=105</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=105</link><title>HUBER+SUHNER   Low Frequency Page 105</title><description>RADOX® MFH MFH–S MFH–P Signal cable screened and unscreened Power cable Certificate no. 43159–02 HH IEC 60332–1:1999 IEC 60754–2:1997 Approvals for MFH-S signal cables GERMANISCHER LLOYD IEC 60092–359:1999 IEC 60754–1:1994 Extract from our delivery programme Cross section n x mm2 2 x 0.4 6 x 1.5 3 x 0.5 25 x 0.5 4 x 2 x 0.75 8 x 2 x 0.75 2x4 4x4 5x4 Stranded dia. mm 2.35 6.4 2.85 7.8 6.9 8.2 8.3 10.3 11.5 R20 IEC 60228 max. Ω/km 54.7 13.7 40.1 40.1 26.7 26.7 5.09 5.09 5.09 IEC 60332–3 cat. A: 1992 IEC61034–2:1997 ZT max.** max. mΩ/m --200 70 80 70 --55 Screen dia. mm --3.3 8.5 7.6 9.0 --12.6 Cable dia. mm 4.1 ± 0.3 8.5 ± 0.3 5.1 ± 0.3 11.0 ± 0.4 10.0 ± 0.3 11.6 ± 0.4 10.8 ± 0.4 13.0 ± 0.4 15.8 ± 0.5 Core colours Weight nom. kg/100 m Type WH num. WN num. bk, bu, bn WN num. WN num. WN num. BK, BU BU, BN, BK, BK BK, BU, BN, BK, BK 2.5 14.2 4.7 23.7 16.4 24.5 18.6 29.7 46.8 MFH-S unscreened MFH-S unscreened MFH-S screened MFH-S screened MFH-S screened MFH-P unscreened MFH-P unscreened MFH-P screened MFH-S screened Other cross sections on request. HUBER+SUHNER 105 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=106</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=106</link><title>HUBER+SUHNER   Low Frequency Page 106</title><description>Hybrid cables 2 x 2 x 0.25 mm2 + 1KO MA14 / REMS FH BK (example out of our product range)      • customised solutions • physical and chemical characteristics according to specifications • power and data transmission • installation of one cable only • small dimensions • low weight • multifunctional     Application Control cable, CCTV for example in tunnels, buildings, airports Composition of cable  coaxialcable75Ω Inner conductor Insulation Screening Sheath  2 pairs of 2 x 0.25 mm2 Conductor Dual wall Colours  3 x fillers  Separator  Sheath Colour Technical data Conductorresistanceat20°C Voltage rating Test voltage Max. conductor temperature Min. operating temperature Min. bending radius CoaxialcableRG_179-B/U: Impedance Capacitance Velocityofsignalpropagation Attenuation at 20 °C (typ. value) . typeRG_179–B/U steel, copper and silver plated PTFE silver plated copper braid FEP, colour: brown type Multi A–14 A2–0.25 tin plated copper high tech polymer blue/brown, black/grey RADOX® plastic tape RADOX® elastomer S FH black Dia: 0.30 mm Dia: 1.53 mm Dia: 2.00 mm Dia: 2.54 mm Dia: 19 x 0.12 mm Dia: 1.02 mm Dia: 2.04 mm Dia: 7.1 ± 0.3 mm &lt;86.0Ω/km 600 V AC 2500 V +120 °C –25 °C 10 x cable–dia. 75Ω 63 pF/m 69%ofthespeedoflight 3.0 dB/100 m 9.5 dB/100 m 30 dB/100 m f = 1 MHz f = 10 MHz f = 100 MHz 106 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=107</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=107</link><title>HUBER+SUHNER   Low Frequency Page 107</title><description>Hybrid cables 3 x 24 AWG + 3 x KO 2253D–02 (example out of our product range) • customised solutions • physical and chemical characteristics according to specifications • power and data transmission • installation of one cable only • small dimensions • low weight • multifunctional      Application Control cable, CCTV for example in tunnels, buildings, airports Composition of cable  3coaxialcables75Ω Inner conductor Insulation Screening 1 Screening 2 Sheath  3 cores 24 AWG Conductor Insulation Colours  Separator  EMV screening  Separator  Sheath Colour Technical data Conductorresistanceat20°C Voltage rating Test voltage Transferimpedance Temperature range Temperature range Coaxial cable K 02253D–02: Impedance Capacitance Velocityofsignalpropagation Attenuation at 20 °C (typ. value) Temperature range typeK02253D–02 steel, copper and silver plated PTFE silver plated copper braid silver plated copper braid FEP, colour: brown type 22759–32A1–24 tin plated copper XETFE white, blue, orange plastic tape tin plated copper braid plastic tape RADOX® elastomer S black f≤30MHz (cores) (sheath) f = 1 MHz f = 10 MHz f = 100 MHz Dia: 0.30 mm Dia: 1.53 mm Dia: 2.00 mm Dia: 2.50 mm Dia: 3.00 mm Dia: 19 x 0.13 mm Dia: 0.94 mm Dia: 7.3 mm Dia: 9.3 ± 0.3 mm &lt;90.5Ω/km 600 V 1500 V 80mΩ/m –50 up to +150 °C –40 up to +150 °C 75Ω 63 pF/m 69%ofthespeedoflight 30 dB/100 m 9.5 dB/100 m 30 dB/100 m –40 up to +150 °C HUBER+SUHNER 107 RADOX® system cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=108</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=108</link><title>HUBER+SUHNER   Low Frequency Page 108</title><description>108 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=109</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=109</link><title>HUBER+SUHNER   Low Frequency Page 109</title><description>RADOX® SOLAR cables RADOX® SOLAR cable single core RADOX® SMART RADOX® SolarLink RADOX® SOLAR cable multi core RADOX® SOLAR cable multi core, screened 108 110 112 114 116 All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS). HUBER+SUHNER 109 RADOX® solar cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=110</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=110</link><title>HUBER+SUHNER   Low Frequency Page 110</title><description>RADOX® SOLAR cable Single core cable       • nominal cross sections with TÜV approval • space saving outer diameter • long service life, extremly robust • electron beam, crosslinked insulation and sheath • high resistance against heat, cold, oil, abrasion, ozone, UV and weather • improved characteristics in case of fire • halogen free, flame retardant • flexible, easy to strip Application Specifically designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions. For permanent installations. Composition of cable Conductor  Insulation  Sheat  Colours Technical data Conductor resistance at 20 °C TüV: stranded tin plated copper, fine wired, acc. to EN 60228, class 5 RADOX® black RADOX® see table Voltage rating line to ground Voltage rating line to line maximum voltage line to ground maximum voltage line to line maximum voltage line to ground maximum voltage line to line test voltage AC test voltage DC lower ambient temperature upper ambient temperature max. conductor temperature D &lt; 8 mm D≥8mm Uo U Um Vo see table 600 V AC 1000 V AC 660 V AC 1100 V AC 1000 V DC 1650 V DC 3.5 kV 8.4 kV –40°C +85°C +110°C Min. bending radius 4 x cable–dia. 6xcable–dia. 110 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=111</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=111</link><title>HUBER+SUHNER   Low Frequency Page 111</title><description>RADOX® SOLAR cable Single core cable Fire tests Flame propagation: Vertical of a single cable Content of halogen acid gas Corrosivity of combustion gases Smoke density Approvals (2.5 – 6.0 mm2) Wires for photovoltaic–systems Extract from our delivery programme Cross section mm2 1.5 2.5* 2.5* 2.5* 4.0* 4.0* 4.0* 6.0* 6.0* 6.0* 10 16 25 35 50 70 95 120 150 Conductor Construction nom. n x mm dia. 30 x 0.25 48 x 0.25 48 x 0.25 48 x 0.25 56 x 0.30 56 x 0.30 56 x 0.30 81 x 0.30 81 x 0.30 81 x 0.30 78 x 0.40 119 x 0.40 182 x 0.40 266 x 0.40 378 x 0.40 348 x 0.50 444 x 0.50 551 x 0.50 722 x 0.50 R20 IEC 60228 max.Ω/km 1.52 ± 0.05 2.01 ± 0.05 2.01 ± 0.05 2.01 ± 0.05 2.54 ± 0.05 2.54 ± 0.05 2.54 ± 0.05 3.30 ± 0.10 3.30 ± 0.10 3.30 ± 0.10 4.30 ± 0.10 5.30 ± 0.10 6.60 ± 0.10 7.80 ± 0.10 9.30 ± 0.10 11.40 ± 0.10 12.80 ± 0.10 14.60 ± 0.10 16.80 ± 0.10 Cable dia. nom. mm 4.3 ± 0.15 5.2 ± 0.15 5.2 ± 0.15 5.2 ± 0.15 5.8 ± 0.15 5.8 ± 0.15 5.8 ± 0.15 6.9 ± 0.20 6.9 ± 0.20 6.9 ± 0.20 8.1 ± 0.15 9.5 ± 0.20 11.1 ± 0.20 12.8 ± 0.25 15.0 ± 0.25 17.5 ± 0.30 19.3 ± 0.30 21.8 ± 0.30 24.4 ± 0.30 Weight nom. kg/100 m 3.2 4.6 4.6 4.6 6.6 6.6 6.6 9.2 9.2 9.2 14.4 21.0 29.6 41.7 60.2 80.8 103.1 126.0 161.7 black red blue black red blue black red blue black black black black black black black black black black 12558072 12529712 12529713 12529714 12545801 12537896 12545802 12568182 12568183 12552756 12537897 12567377 12567378 12567379 12567380 12567381 12567382 12567383 12567384 Colour Item no. IEC 60332–1, EN 50265–2–1 IEC 670754–1, EN 50267–2–1 IEC 60754–2, EN 50267–2–3 IEC 61034–2, EN 50268–2 0mg/g RADOX® solar cable TÜV Rheinland 2 Pfg 1169 certificate R02210086 *Approvals: TÜV Rheinland design–tested, certificate R 02210086 Other cross sections and colours on request. HUBER+SUHNER 111 RADOX® solar cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=112</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=112</link><title>HUBER+SUHNER   Low Frequency Page 112</title><description>RADOX® SMART Single core cable       • for all climate zones • for reliable and durable connections • with UL and TÜV approvals • halogen free, flame retardant • lean, powerful and flexible • of proven RADOX® quality Composition of cable Conductor  Inner insulation  Outer insulation  Colour Technical data UL: stranded tin plated copper, fine wired, acc. to EN 60228, class 5 RADOX® FI RADOX® FS black voltage rating test voltage temperature rating Voltage rating line to ground Voltage rating line to line maximum voltage line to ground maximum voltage line to line test voltage AC test voltage DC lower ambient temperature upper ambient temperature maximum conductor temperature 600 V AC 3.0 kV AC 90 °C wet or dry, sunlight resistant Uo U Vo 600 V AC 1000 V AC 1000 V DC 1650 V DC 3.5 kV AC 8.4 kV DC –40 °C +85 °C +110 °C 4 x cable–dia. TÜV: Minimum bending radius Application • Type PV: Suitable for interconnection wiring of grounded and ungrounded photovoltaic power systems as descriebed in section 690.31 (A) and other parts of the National Electrical Code (NEC), NFPA 70. For single conductor, double--insulated wires installation without using a conduit is permitted according to section 690.35 (D) of the NEC. • Type RHH oder RHW--2: Suitable for any of the wiring methods recognised in chapter 3 and as specified in their respective tables or as permitted elsewhere in the NEC. Europe: • Suitable for the installation methods reference no. 2, 3A, 4A, 5A, 11, 11A, 12, 13, 14, 15, 16, 21, 22A, 23A, 24A, 25, 31A, 32A, 33A, 41, 43, 51, 72, 73, 75 in table 52H of HD 384.5.52 (CH: SEV 1000 section 5.2; DE: DIN VDE 0100--520). 112 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=113</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=113</link><title>HUBER+SUHNER   Low Frequency Page 113</title><description>RADOX® SMART Single core cable Fire tests flame propagation: VerticalFT1 Vertical Contentofhalogenacidgas Corrosivityofcombustiongases Approvals UL UL TÜV Rheinland Photovoltaic Wire Thermoset–insulated Wires and Cables Wires for photovoltaic–systems Type PV, UL subject 4703, UL listed E305787 Type RHH kand RHW–2, UL 44, listed E310273 2 Pfg 1169, certificate R60017683 UL1581#1060 EN 60332–1–2 IEC60332–1–2 EN50267–2–1,IEC60754–1 EN50267–2–2,IEC60754–2 L≤250mm,T≤60s 50&lt;L≤540mm HCI+HBr≤0.5% pH≥4.3,σ≤10μS/mm Extract from our delivery programme Cross section nom. AWG 14 12 10 mm2 2.5 4.0 6.0 Constr. nom. n x mm dia. 48 x 0.26 61 x 0.29 82 x 0.30 Conductor dia. nom. nom. mm 2.0 2.5 3.2 R20 IEC 60228 max.Ω/km 8.21 5.09 3.39 Cable dia. mm 5.3 5± 0.10 6.05 ± 0.10 7.15 ± 0.15 Weight nom. kg/100 m 5.1 7.1 9.9 12583222 12583780 12583781 Item no. HUBER+SUHNER 113 RADOX® solar cables Other cross sections and colours on request.</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=114</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=114</link><title>HUBER+SUHNER   Low Frequency Page 114</title><description>RADOX® SolarLink Single core cable       • UL and TÜV approval • double insulated construction allows for installation without a conduit • smaller outer diameter • of proven RADOX® quality • very flexible Composition of cable Conductor  Inner insulation  Outer insulation  Colour Technical data UL: stranded tin plated copper, fine wired, acc. to EN 60228, class 5 RADOX® 155 RADOX® 155 black voltage rating test voltage AC temperature rating Voltage rating line to ground Voltage rating line to line maximum voltage line to ground maximum voltage line to line test voltage AC test voltage DC lower ambient temperature upper ambient temperature maximum conductor temperature 600 V AC 3.0 kV AC 90 °C wet or dry, sunlight resistant Uo U Vo 600 V AC 1000 V AC 1000 V DC 1650 V DC 3.5 kV AC 8.4 kV DC –40 °C +85 °C +110 °C 4 x cable–dia. TÜV: Min. bending radius Application United States: • Type PV: suitable for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in section 690.31 (A) and other parts of the National Electrical Code (NEC), NFPA 70. For single conductor, double insulated wires installation without using a conduit is permitted according to section 690.35 (D) of the NEC. • Type RHH or RHW-2: suitable for use in any of the wiring methods recognized in chapter 3 and as specified in their respective tables or as permitted elsewhere in the NEC. Europe: • suitable for the installation mehods reference no. 2, 3A, 4A, 5A, 11, 11A, 12, 13, 14, 15, 16, 21, 22A, 23A, 24A, 25, 31A, 32A, 33A, 41, 43, 51, 72, 73, 75 given in table 52H of HD 384.5.52 (CH: SEV 1000 cl. 5.2; DE: DIN VDE 0100-520). 114 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=115</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=115</link><title>HUBER+SUHNER   Low Frequency Page 115</title><description>RADOX® SolarLink Single core cable Fire tests Flame propagation: VerticalFT1 Vertical Approvals UL UL TÜV Rheinland Photovoltaic Wire Thermoset–insulated Wires and Cables Wires for photovoltaic–systems Type PV, UL subject 4703, UL listed E305787 Type RHH kand RHW–2, UL 44, listed E310273 2 Pfg 1169, certificate R60017683 UL1581#1060 EN60332–1–2,IEC60332–1–2 L≤250mm,T≤60s 50&lt;L≤540mm Extract from our delivery programme Cross section nom. AWG 14 12 10 mm2 2.5 4.0 6.0 Constr. nom. n x mm dia. 48 x 0.26 56 x 0.30 82 x 0.30 Conductor dia. max. nom. mm 2.0 2.5 3.2 R20 IEC 60228 max.Ω/km 8.21 5.09 3.39 Cable dia. mm 5.35 ± 0.10 6.05 ± 0.10 7.15 ± 0.15 Weight nom. kg/100 m 5.1 7.1 9.9 12582664 12582665 12583784 Item no. Other cross sections and colours on request. HUBER+SUHNER 115 RADOX® solar cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=116</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=116</link><title>HUBER+SUHNER   Low Frequency Page 116</title><description>RADOX® SOLAR cable Multi core cable       • high resistance against heat, ozone and weatherproof • extremely mechanically robust, very long lifetime • halogen free • space saving, easy to install • flame retardant • no corrosive gases and low smoke occurrence in case of fire • soldering resistant • flexible, easy to strip Application Connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather influences. For permanent installations. Composition of cable Conductor  Insulation  Colour Sheat  Colour Technical data Voltage rating Test voltage Temperature range Min. operating temperature Max. conductor temperature Min. bending radius stranded tin plated copper, fine wired, acc. to EN 60228, class 5 RADOX® 125 2–5 cores acc. to CENELEC, HD 308 S2 (see page 139) as of 6 cores black-numbered with earth conductor yellow-green (other colours on request) RADOX® 125 black fixed flexing (short circuit at max. 5s) fixed flexing 1000V DC or 600 / 1000V AC 3500 V AC –40 up to +125 °C –25 °C + 280 °C 3 x cable–dia. 5 x cable–dia. 116 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=117</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=117</link><title>HUBER+SUHNER   Low Frequency Page 117</title><description>RADOX® SOLAR cable Multi core cable Fire tests Flame propagation: Vertical of a single cable Vertical of bunched cable Content of halogen acid gas Corrosivity of combustion gases Smoke density Extract from our delivery programme Cross section mm2 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 2 x 4.0 4 x 4.0 5 x 4.0 4 x 6.0 2 x 10.0 3 x 10.0 4 x 10.0 5 x 10.0 Conductor Construction nom. n x mm dia. 48 x 0.25 48 x 0.25 48 x 0.25 48 x 0.25 48 x 0.25 56 x 0.30 56 x 0.30 56 x 0.30 81 x 0.30 78 x 0.40 78 x 0.40 78 x 0.40 78 x 0.40 dia. nom. mm 2.05 2.05 2.05 2.05 2.05 2.60 2.60 2.60 3.40 4.40 4.40 4.40 4.40 Core dia. nom. mm 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 4.15 ± 0.15 4.15 ± 0.15 4.15 ± 0.15 4.95 ± 0.15 6.15 ± 0.15 6.15 ± 0.15 6.15 ± 0.15 6.15 ± 0.15 Cable dia. nom. mm 9.1 ± 0.3 10.1 ± 0.4 11.4 ± 0.4 12.4 ± 0.4 15.3 ± 0.5 11.0 ± 0.4 13.0 ± 0.4 14.6 ± 0.4 15.6 ± 0.5 15.8 ± 0.5 17.0 ± 0.5 18.9 ± 0.5 21.4 ± 0.5 Weight nom. kg/100 m 13.0 16.6 20.9 24.9 37.9 18.7 29.8 36.7 41.8 50.4 62.0 77.5 98.3 EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 EN 50267–2–1, IEC 60754–1 EN 50267–2–2, IEC 60754–2 EN 50268–2, IEC 61034–2 Category C 0 mg/g Other cross sections and colours on request. HUBER+SUHNER 117 RADOX® solar cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=118</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=118</link><title>HUBER+SUHNER   Low Frequency Page 118</title><description>RADOX® SOLAR cable Multi core cable – screened     • high resistance against heat, ozone and weatherproof • extremely mechanically robust, very long lifetime • halogen free • space saving, easy to install    Application For connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions. For permanent installations. Composition of cable Conductor  Insulation  Colour Screening   Sheat Colour Technical data Voltage rating Test voltage Temperature range Min. operating temperature Max. conductor temperature Min. bending radius stranded tin plated copper, fine wired, acc. to EN 60228, class 5 RADOX® 125 2–5 cores acc. to CENELEC, HD 308 S2 (see page 139) as of 6 cores black-numbered with earth conductor yellow-green (other colours on request) tin plated copper braid RADOX® 125 black fixed flexing (short circuit at max. 5s) fixed flexing 1000V DC or 600 / 1000V AC 3500V AC –40 up to +125 °C –25 °C +280 °C 3 x cable–dia. 5 x cable–dia. 118 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=119</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=119</link><title>HUBER+SUHNER   Low Frequency Page 119</title><description>RADOX® SOLAR cable Multi core cable – screened Fire tests Flame propagation: Vertical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density Extract from our delivery programme Cross section mm2 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 2 x 4.0 4 x 4.0 3 x 6.0 4 x 6.0 Conductor Construction nom. n x mm dia. 48 x 0.25 48 x 0.25 48 x 0.25 48 x 0.25 48 x 0.25 56 x 0.30 56 x 0.30 81 x 0.30 81 x 0.30 dia. nom. mm 2.05 2.05 2.05 2.05 2.05 2.60 2.60 3.40 3.40 Core dia. nom. mm 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 3.50 ± 0.10 4.15 ± 0.15 4.15 ± 0.15 4.95 ± 0.15 4.95 ± 0.15 Screening dia. nom. mm 7.7 8.3 9.8 10.4 13.2 9.2 11.2 11.6 13.3 Cable dia. nom. mm 10.2 ± 0.4 10.8 ± 0.4 12.0 ± 0.4 13.1 ± 0.4 16.3 ± 0.5 11.9 ± 0.4 14.1 ± 0.4 14.5 ± 0.4 16.5 ± 0.5 Weight nom. kg/100 m 17.5 20.6 26.8 30.9 45.9 24.4 37.1 38.8 51.7 EN 50265–2–1, IEC 60332–1 EN 50266–2–4, IEC 60332–3–24 EN 50267–2–1, IEC 60754–1 EN 50267–2–2, IEC 60754–2 EN 50268–2, IEC 61034–2 Category C 0mg/g Other cross sections and colours on request. RADOX® solar cables HUBER+SUHNER 119</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=120</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=120</link><title>HUBER+SUHNER   Low Frequency Page 120</title><description>120 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=121</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=121</link><title>HUBER+SUHNER   Low Frequency Page 121</title><description>RADOX® FR Safety cables with circuit integrity in case of fire RADOX® FR AUS, single core RADOX® FR AUS multi core cable, 0.75 – 2.5 mm RADOX® FR AUS multi core cable, 4.0 – 35 mm RADOX® FR INTERNATIONAL cores, single and multi core cable RADOX® FR INTERNATIONAL ALU communication cable 120 122 124 126 130 All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS). HUBER+SUHNER 121 RADOX® FR safety cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=122</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=122</link><title>HUBER+SUHNER   Low Frequency Page 122</title><description>RADOX® FR AUS Single core cable with circuit integrity in case of fire       • halogen free • flame retardant • in case of fire no corrosive gases and low smoke • circuit integrity in case of fire • excellent high and low temperature, and ozone resistance • weatherproof • easy to strip Application For emergency support systems: emergency lighting, smoke spill fans, fire alarms and sprinklers, emergency evacuation intercommunication systems, etc. Composition of cable Core  Flame barrier  Insulation  Technical data Voltage rating Test voltage Max. conductor temperature Max. conductor temperature Min. operating temperature Min. conductor temperature Min. bending radius stranded bare copper acc. to EN 60228, class 2 RADOX® 125 (short circuit max. 5s) flexing fixed fixed flexing 600 / 1000 V 3500 V AC +110 °C +280 °C –25 °C –40 °C 6 x cable–dia. 10 x cable–dia. Fire tests Content of halogen acid gas Corrosivity of combustion gases Smoke density Circuit integrity 180 Min. Circuit integrity IEC 60754–1, EN 50267–2–1 IEC 60754–2, EN 50267–2–3 IEC 61034–2, EN 50268–2 IEC 60331–21 AS/NZS 3013, WS5 0 mg/g 122 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=123</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=123</link><title>HUBER+SUHNER   Low Frequency Page 123</title><description>RADOX® FR AUS Single core cable with circuit integrity in case of fire Extract from our delivery programme Cross section Construction nom. n x mm dia. 7 x 0.54 7 x 0.69 Conductor R20 IEC 60228 max.Ω/km 11.50 7.56 Core mm2 1.5 2.5 dia. nom. mm 1.62 2.07 dia. nom. mm 3.50 4.10 Colour black black Weight nom. kg/100 m 2.5 3.7 Fire load kj/m 180 266 HUBER+SUHNER 123 RADOX® FR safety cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=124</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=124</link><title>HUBER+SUHNER   Low Frequency Page 124</title><description>RADOX® FR AUS – 0.75 to 2.5 mm2 Multi core cable with circuit integrity in case of fire – LSFH        • halogen free • flame retardant • in case of fire no corrosive gases and low smoke • circuit integrity in case of fire • excellent high and low temperature, and ozone resistance • weatherproof • easy to strip Application For emergency support systems: emergency lighting, smoke spill fans, fire alarms and sprinklers, emergency evacuation intercommunication systems, etc. Composition of cable  Cores Conductor Flame barrier Insulation Colours Fillers (optional)   Conductor Insulation Colour Sheath  Colour Technical data Voltage rating Test voltage Temperature range Min. bending radius Fire tests Flame propagation:: Vertical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density Circuit integrity 180 Min. Circuit integrity stranded bare copper acc, to EN 60228, class 5 RADOX® 125 see table RADOX® stranded bare copper acc, to EN 60228, class 5 RADOX® 125 yellow-green LSFH see table 0.75 and 1.0 mm2 1.5 and 2.5 mm2 fixed 300 / 500 V 600 / 1000 V 3500 V –40 °C up to +90 °C 10 x cable–dia. IEC 60332–1, EN 50265–2–1 IEC 60332–3–24, EN 50266–2–4 IEC 60754–1, EN 50267–2–1 IEC 60754–2, EN 50267–2–3 IEC 61034–2, EN 50268–2 IEC 60331–21 AS/NZS 3013, WS5 category C 0 mg/g 124 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=125</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=125</link><title>HUBER+SUHNER   Low Frequency Page 125</title><description>RADOX® FR AUS – 0.75 bis 2.5 mm2 Multi core cable with circuit integrity in case of fire – LSFH Extract from our delivery programme Cross section Construction nom. n x mm dia. 7 x 0.37 7 x 0.37 7 x 0.37 7 x 0.37 7 x 0.37 7 x 0.43 7 x 0.43 7 x 0.43 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.53 7 x 0.67 7 x 0.67 7 x 0.67 7 x 0.67 7 x 0.67 7 x 0.67 7 x 0.67 7 x 0.67 7 x 0.67 Conductor dia. mm 1.11 1.11 1.11 1.11 1.11 1.29 1.29 1.29 1.59 1.59 1.59 1.59 1.59 1.59 1.59 1.59 1.59 1.59 1.59 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.01 R20 IEC 60228 max.Ω/km 24.8 24.8 24.8 24.8 24.8 18.2 18.2 18.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 dia. mm 2.5 2.5 2.5 2.5 2.5 3.1 3.1 3.1 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 Core colours* Colour WH,RD WH,RD,BU WH,RD,BK,BU WH numb. WH numb. WH,RD WH,RD,BU WH,RD,BK,BU WH,RD WH,RD,BU RD,BK,GNYE WH,RD,BK,BU WH,RD,BK,GNYE WH,RD,BK,BU,GNYE Cable dia. mm 7.8 8.4 9.3 14.5 19.2 8.5 9.1 10.3 9.2 9.9 10.9 12.1 13.1 17.4 17.9 20.3 22.6 32.3 36.3 10.6 11.3 12.6 14.0 15.4 20.8 20.8 26.3 40.8 16.7 20.1 25.3 31.7 39.6 60.5 64.6 106 244 1715 1858 1341 2525 3231 4828 5188 7759 17928 Weight nom. kg/100 m 8.1 9.6 11.8 25.5 46.6 9.8 11.7 14.8 12.1 14.5 18.2 22.8 27.4 40.4 44.9 59.2 73.9 144.5 Fire load kJ / m 955 1055 1250 2474 4274 1131 1248 1519 1305 1446 1724 2125 2363 3464 3756 4824 5875 11150 Colour RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD OG RD RD RD RD RD RD RD RD RD RD mm2 2x0.75 3x0.75 4x0.75 10x0.75 20x0.75 2x1.0 3x1.0 4x1.0 2x1.5 3x1.5 3G1.5 4x1.5 4G1.5 5G1.5 7x1.5 7G1.5 10x1.5 12G1.5 16x1.5 21G1.5 41G1.5 56G1.5 2x2.5 3x2.5 3G2.5 4x2.5 4G2.5 5G2.5 7G2.5 11G2.5 12G2.5 21G2.5 50x2.5 WH numb. BK numb, GNYE WH numb. WH numb.,GNYE WH numb. WH numb,GNYE WH numb.,GNYE BK numb.,BU,GNYE WH,RD WH,RD,BU RD,BK,GNYE WH,RD,BK,BU WH, RD,BU,GNYE WH,RD,BK,BU,GNYE WH numb.GNYE WH numb.GNYE WH numb.GNYE WH numb.GNYE WH numb. * Description for core colours see page 138 HUBER+SUHNER 125 RADOX® FR safety cables RD</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=126</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=126</link><title>HUBER+SUHNER   Low Frequency Page 126</title><description>RADOX® FR AUS – 4.0 – 35 mm2 Multi core cable with circuit integrity in case of fire – RADOX® 125        • halogen free • flame retardant • in case of fire no corrosive gases and low smoke • circuit integrity in case of fire • excellent high and low temperature, and ozone resistance • weatherproof • easy to strip Application For emergency support systems: emergency lighting, smoke spill fans, fire alarms and sprinklers, emergency evacuation intercommunication systems, etc. Aufbau Cores  Conductor Flame barrier Insulation  Fillers (optional)  Conductor Insulation Colours  Sheath Colour Technical data Voltage rating Test voltage Max. conductor temperature Max. conductor temperature Min. operating temperature Min. conductor temperature Min. bending radius Fire tests Flame propagation: Vertical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density Circuit integrity 180 Min. Circuit integrity stranded bare copper, 4 and 6 mm2 stranded bare copper, 10 up to 120 mm2 RADOX® 125, colours see table RADOX® stranded bare copper, 4 and 6 mm2 stranded bare copper, 10 up to 120 mm2 RADOX® 125 yellow–green RADOX® 125 see table 600 / 1000 V 3500 V AC +110 °C +280 °C –25 °C –40 °C 6 x cable–dia. 10 x cable–dia. (short circuit max. 5s) flexing fixed fixed flexing IEC 60332–1, EN 50265–2–1 IEC 60332–3–24, EN 50266–2–4 IEC 60754–1, EN 50267–2–1 IEC 60754–2, EN 50267–2–3 IEC 61034–2, EN 50268–2 IEC 60331–21 AS/NZS 3013, WS5 category C 0 mg/g 126 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=127</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=127</link><title>HUBER+SUHNER   Low Frequency Page 127</title><description>RADOX® FR AUS – 4.0 – 35 mm2 Multi core cable with circuit integrity in case of fire – RADOX® 125 Extract from our delivery programme Cross section Construction nom. n x mm dia. 7 x 0.86 7 x 0.86 7 x 0.86 Conductor dia. mm 2.58 2.58 2.58 R20 IEC 60228 max.Ω/km 4.70 4.70 4.70 dia. mm 4.4 4.4 4.4 Core Colour* BK,RD WH,RD WH,RD,BU RD,BK,GNYE WH,RD,BK,BU WH,RD,BU,GNYE WH,RD,BK,BU,GNYE Cable dia. mm 12.1 12.9 14.6 16.2 13.6 14.5 16.4 18.1 17.9 19.0 21.1 22.9 20.7 23.1 23.1 25.2 24.4 27.0 30.3 26.9 29.7 33.6 Weight nom. kg/100 m 23.0 28.1 36.4 44.9 30.5 37.0 48.8 59.8 53.8 63.6 78.3 96.1 84.5 108.3 75.1 127.4 126.3 157.4 197.5 160.6 203.6 257.6 1130 4 1391 2 1054 1176 1 7683 6144 7132 2892 2996 1430 3778 4378 Fire load kJ / m 2313 2468 3047 Colour OG RD RD red RD RD RD RD RD RD RD OG OG OG OG OG OG OG OG OG OG OG OG OG OG OG OG OG OG mm2 2x4 2x4 3x4 3G4 4x4 4G4 5G4 2x6 3G6 4G6 5G6 2x10 3x10 3G10 4x10 4G10 5G10 3x16 4x16 4G16 5G16 3x25 4x25 4G25 5G25 3x35 4x35 4G35 5G35 7 x 1.07 7 x 1.07 7 x 1.07 7 x 1.07 7 x 1.36 7 x 1.36 7 x 1.36 7 x 1.36 7 x 1.36 7 x 1.36 7 x 1.70 7 x 1.70 7 x 2.15 7 x 2.15 7 x 2.15 7 x 2.53 7 x 2.53 7 x 2.53 3.21 3.21 3.21 3.21 4.08 4.08 4.08 4.08 4.08 4.08 4.85 4.85 6.10 6.10 6.10 7.2 7.2 7.2 3.11 3.11 3.11 3.11 1.83 1.83 1.83 1.83 1.83 1.83 1.15 1.15 0.734 0.734 0.734 0.524 0.524 0.524 5.0 5.0 5.0 5.0 6.6 6.6 6.6 6.6 6.6 6.6 7.5 7.5 9.2 9.2 WH,RD RD,BK,GNYE WH,RD,BU,GNYE WH,RD,BK,BU,GNYE BK,RD WH,RD, BURD,BK,GNYE WH,RD,BK,BU WH,RD,BU, GNYE WH,RD,BK,BU,GNYE WH,RD,BU WH,RD,BK,BU WH,RD,BU,GNYE WH,RD,BK,BU,GNYE WH,RD,BU WH,RD,BK,BU WH,RD,BU,GNYE WH,RD,BK,BU,GNYE 10.3 10.3 10.3 WH,RD,BU WH,RD,BK,BU WH,RD,BU,GNYE WH,RD,BK,BU,GNYE * Description for core colours see page 138 HUBER+SUHNER 127 RADOX® FR safety cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=128</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=128</link><title>HUBER+SUHNER   Low Frequency Page 128</title><description>RADOX® FR INTERNATIONAL Single core or multi core cables with circuit integrity in case of fire • halogen free • flame retardant • in case of fire no corrosive gases and low smoke • circuit integrity in case of fire • excellent high and low temperature, and ozone resistance • weatherproof • easy to strip     A  B C Application For emergency support systems: emergency lighting, smoke spill fans, fire alarms and sprinklers, emergency evacuation intercommunication systems, etc. Composition of cable  Filler (optional)  Cores &lt;1.5 mm2 2.5 and 4.0 mm2 &gt;4.0 mm2  Flame barrier  Insulation Colour  Sheath Colour Technical data Voltage rating Uo/U Testvoltage Voltage rating Uo/U Testvoltage Max. conductor temperature Max. conductor temperature Min. operating temperature Min. conductor temperature Min. bending radius RADOX® conductor: tin plated copper OF copper, class 2 conductor: tin plated copper OF copper, class 2 conductor: tin plated ETP copper class 2 RADOX® 125 crosslinked HD 308 S2 (see page 139) RADOX® 125 crosslinked orange ≤1.0mm2 ≤1.0mm2 ≤1.5mm2 ≤1.5mm2 (short circuit max. 5s) flexing fixed 470 / 750 V 2500 V AC 600 / 1000 V 3500 V AC +110 °C +280 °C –25 °C –40 °C 10 x cable–dia. 128 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=129</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=129</link><title>HUBER+SUHNER   Low Frequency Page 129</title><description>RADOX® FR INTERNATIONAL Single core cables with circuit integrity in case of fire Fire tests Flame propagation: Vertical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density Circuit integrity 180 Min. IEC 60332–1, EN 50265–2–1 IEC 60332–3–24, EN 50266–2–4 IEC 60754–1, EN 50267–2–1 IEC 60754–2, EN 50267–2–3 IEC 61034–2, EN 50268–2 IEC 60331–21 category C 0 mg/g Core (drawing A) Extract from our delivery programme Cross section nom. mm2 0.75 1.0 1.0 1.5 1.5 1.5 2.5 2.5 4.0 6.0 10 16 25 35 Constr. nom. n x mm dia. 7 x 0.38 7 x 0.45 7 x 0.45 7 x 0.54 7 x 0.54 7 x 0.54 7 x 0.69 7 x 0.69 7 x 0.88 7 x 1.07 7 x 1.36 7 x 1.70 7 x 2.15 7 x 2.53 Conductor dia. nom. mm 1.18 1.37 1.37 1.66 1.66 1.66 2.12 2.12 2.67 3.24 4.13 4.90 6.15 7.25 R20 IEC60228 max.Ω/km 23.8 17.5 17.5 11.7 11.7 11.7 7.11 7.11 4.43 2.96 1.79 1.13 0.712 0.514 dia. nom. mm 2.6 2.9 2.9 3.5 3.5 3.5 3.95 3.95 4.55 5.1 6.0 6.8 8.5 9.6 Core A Cable Colour* BK BK WH BK BU RD BK RD BK BK BK BK BK BK dia. nom. mm –– –– –– –– –– –– –– –– –– –– –– –– –– –– Weight nom. kg/100 m 1.32 1.70 1.70 2.49 2.49 2.49 3.61 3.61 5.31 7.31 10.9 16.9 26.6 36.0 * Description for core colours see page 138 HUBER+SUHNER 129 RADOX® FR safety cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=130</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=130</link><title>HUBER+SUHNER   Low Frequency Page 130</title><description>RADOX® FR INTERNATIONAL Single core cables with circuit integrity in case of fire Single core cable (drawing B) Extract from our delivery programme Cross section nom. mm2 1 x 1.5 1 x 2.5 1 x 4.0 1 x 6.0 1 x 10 1 x 16 1 x 25 1 x 35 Construction nom. n x mm dia. 7 x 0.54 7 x 0.69 7 x 0.88 7 x 1.07 7 x 1.36 7 x 1.70 7 x 2.15 7 x 2.53 Conductor dia. nom. mm 1.66 2.12 2.67 3.24 4.13 4.90 6.15 7.25 R20 IEC60228 max.Ω/km 11.7 7.11 4.43 2.96 1.79 1.13 0.712 0.514 dia. nom. mm 3.5 3.95 4.55 5.1 6.0 6.8 8.5 9.6 Cores B Cable Colour* BN BN BN BN BN BN BN BN dia. nom. mm 5.05 5.6 6.3 6.85 9.0 9.8 11.5 12.7 Weight nom. kg/100 m 4.08 5.49 7.57 9.83 16.3 22.8 33.8 44.2 * Description for core colours see page 138 130 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=131</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=131</link><title>HUBER+SUHNER   Low Frequency Page 131</title><description>RADOX® FR INTERNATIONAL Multicore cables with circuit integrity in case of fire Multi core cable (drawing C) Extract from our delivery programme Cross section nom. mm2 2 x 0.75 2 x 1.0 2 x 1.5 2 x 1.5 2 x 2.5 2 x 2.5 3 x 0.75 3 G 1.5 3 x 2.5 3 G 2.5 3 x 6.0 3 x 16 4 G 1.5 4 G 4.0 4 G 6.0 4 x 10 4 x 16 4 x 25 4 x 35 5 G 1.5 5 G 2.5 5 G 6.0 5 G 10 5 G 16 10 x 1.5 10 x 1.5 4 x 25 + 1 G 16 Construction nom. n x mm dia. 7 x 0.38 7 x 0.45 7 x 0.54 7 x 0.54 7 x 0.69 7 x 0.69 7 x 0.38 7 x 0.54 7 x 0.69 7 x 0.69 7 x 1.07 7 x 1.70 7 x 0.54 7 x 0.88 7 x 1.07 7 x 1.36 7 x 1.70 7 x 2.15 7 x 2.53 7 x 0.54 7 x 0.69 7 x 1.07 7 x 1.36 7 x 1.70 7 x 0.54 7 x 0.54 7 x 2.15 7 x 1.70 Conductor dia. nom. mm 1.18 1.37 1.66 1.66 2.12 2.12 1.18 1.66 2.12 2.12 3.24 4.90 1.66 2.67 3.24 4.13 4.90 6.15 7.25 1.66 2.12 3.24 4.13 4.90 1.66 1.66 6.15 4.90 R20 IEC 60228 max.Ω/km 24.8 18.2 12.2 12.2 7.41 7.41 24.8 12.2 7.41 7.41 3.08 1.15 12.2 4.614.55 3.08 1.83 1.15 0.727 0.524 12.2 7.41 3.08 1.83 1.15 12.2 12.2 0.727 1.15 dia. nom. mm 2.6 2.9 3.5 3.5 3.95 3.95 2.6 3.5 3.95 3.95 5.1 6.8 3.5 bn, 5.1 6.0 6.8 8.5 9.6 3.5 3.95 5.1 6.0 6.8 3.5 3.5 8.5 6.8 Cores Colour* BN,BU BN,BU BN,BU BN,BU BN,BU BN,BU BN,BK,GY BN,BU,GNYE BN,BK,GY BN,BU,GNYE BN,BK,GY BN,BK,GY BN,BK,GY,GNYE BK,GY,GNYE BN,BK,GY,GNYE BN,BK,GY,BU BN,BK,GY,BU BN,BK,GY,BU BN,BK,GY,BU BU,BN,BK,GY,GNYE BU,BN,BK,GY,GNYE BU,BN,BK,GY,GNYE BU,BN,BK,GY,GNYE BU,BN,BK,GY,GNYE BK,YE num. BK,YE num. BU,BN,BK,GY,GNYE C Cable dia. nom. mm 7.1 7.8 7.0 9.2 7.9 10.3 7.6 9.9 10.9 10.9 13.8 18.8 11.0 13.9 15.6 18.9 20.7 25.2 28.1 12.1 13.5 17.5 20.6 22.7 17.4 20.5 27.7 Weight nom. kg/100 m 7.05 5.43 5.01 12.2 7.25 16.2 8.75 14.8 19.4 19.4 35.3 76.0 18.5 34.3 45.7 68.9 96.2 148 194 22.4 30.3 57.6 118 40.9 59.4 171 without sheath without sheath Note * Description for core colours see page 138 HUBER+SUHNER 131 RADOX® FR safety cables 83.2</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=132</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=132</link><title>HUBER+SUHNER   Low Frequency Page 132</title><description>RADOX® FR INTERNATIONAL ALU Communication cable with circuit integrity in case of fire      • halogen free • flame retardant • in case of fire no corrosive gases and low smoke • circuit integrity in case of fire • excellent high and low temperature, and ozone resistance • weatherproof • easy to strip    Application For emergency support systems: emergency lighting, smoke spill fans, fire alarms and sprinklers, emergency evacuation intercommunication systems, etc. Composition of cable  Cores &lt;1.5 mm2 Conductor Flame barrier Insulation Colours  Fillers (optional) Filler  Screening  Separator (optional)  Sheath Colour Technical data Voltage rating Uo/U Test voltage, 50 Hz, 1 Min. Temperature range Min. bending radius Fire tests Flame propagation: Vertical of a single cable Vertical of bunched cables Content of halogen acid gas Corrosivity of combustion gases Smoke density Circuit integrity 180 Min. bare copper OF copper, class 2 RADOX® 125 crosslinked white, black numbered RADOX® stranded bare copper OF copper, class 2 aluminium tape, plastic coated plastic tape RADOX® 125 crosslinked red 300 / 500 V 2000 V –40 °C up to +110 °C 10 x cable–dia. IEC 60332–1, EN 50265–2–1 IEC 60332–3–24, EN 50266–2–4 IEC 60754–1, EN 50267–2–1 IEC 60754–2, EN 50267–2–3 IEC 61034–2, EN 50268–2 IEC 60331–21 category C 0 mg/g 132 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=133</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=133</link><title>HUBER+SUHNER   Low Frequency Page 133</title><description>RADOX® FR INTERNATIONAL ALU Communication cable with circuit integrity in case of fire Extract from our delivery programme Cross section nom. mm2 1 x 2 x 0.5 2 x 2 x 0.5 3 x 2 x 0.5 5 x 2 x 0.5 7 x 2 x 0.5 10 x 2 x 0.5 1 x 2 x 0.75 2 x 2 x 0.75 3 x 2 x 0.75 5 x 2 x 0.75 7 x 2 x 0.75 10 x 2 x 0.75 1 x 2 x 1.0 2 x 2 x 1.0 3 x 2 x 1.0 5 x 2 x 1.0 7 x 2 x 1.0 10 x 2 x 1.0 1 x 3 x 1.0 1 x 4 x 1.0 1 x 2 x 1.5 2 x 2 x 1.5 Conductor R20 IEC Construction nom. dia. nom. 60228 n x mm dia. mm max.Ω/km 7 x 0.31 7 x 0.31 7 x 0.31 7 x 0.31 7 x 0.31 7 x 0.31 7 x 0.38 7 x 0.38 7 x 0.38 7 x 0.38 7 x 0.38 7 x 0.38 7 x 0.44 7 x 0.44 7 x 0.44 7 x 0.44 7 x 0.44 7 x 0.44 7 x 0.44 7 x 0.44 7 x 0.54 7 x 0.54 0.97 0.97 0.97 0.97 0.97 0.97 1.18 1.18 1.18 1.18 1.18 1.18 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.66 1.66 36.7 36.7 36.7 36.7 36.7 36.7 24.8 24.8 24.8 24.8 24.8 24.8 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 12.2 12.2 dia. nom. mm 2.4 2.4 2.4 2.4 2.4 2.4 2.6 2.6 2.6 2.6 2.6 2.6 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.5 3.5 Cores Drain wire dia. nom. mm2 0.97 0.97 0.97 0.97 0.97 0.97 1.18 1.18 1.18 1.18 1.18 1.18 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.66 1.66 Cable dia. nom. mm 6.8 11.2 12.1 15.6 16.0 20.0 7.3 12.2 12.9 17.2 17.3 21.6 7.9 13.5 14.3 19.1 19.1 24.1 8.5 9.4 9.3 16.0 Weight nom. kg/100 m 6.1 14.2 16.9 25.5 28.6 40.2 7.4 17.4 19.9 31.6 35.0 49.0 9.0 21.6 24.8 39.4 43.4 62.2 11.3 13.8 12.5 30.0 12581936 12581937 12581938 12581939 12581940 12581941 12581942 12581943 12581944 12581945 12581946 12581947 12581948 12581949 12581950 12581951 12581952 12581953 12581954 12581955 12581956 12581957 Item no. Core numbers 1+2 1/2 – 3/4 1/2 – 5/6 1/2 – 9/10 1/2 – 13/14 1/2 – 19/20 1+2 1/2 – 3/4 1/2 – 5/6 1/2 – 9/10 1/2 – 13/14 1/2 – 19/20 1+2 1/2 – 3/4 1/2 –– 5/6 1/2 – 9/10 1/2 – 13/14 1/2 – 19/20 1–3 1–4 1+2 1/2 – 3/4 * Description for core colours see page 138 HUBER+SUHNER 133 RADOX® FR safety cables</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=134</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=134</link><title>HUBER+SUHNER   Low Frequency Page 134</title><description>134 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=135</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=135</link><title>HUBER+SUHNER   Low Frequency Page 135</title><description>General technical information Electrical formulas Table of three phase current Material characteristics Colour table Material designations Core colours Resistance to cold and heat Standards Conversion AWG Thermal classes of insulating materials according to IEC 60085 Wire cross sections Guide to installation Delivery spools EMC screened cables Protection of equipment Fire test methods Current carrying capacity 134 135 136 138 138 139 140 141 142 142 143 145 146 147 149 150 153 HUBER+SUHNER 135 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=136</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=136</link><title>HUBER+SUHNER   Low Frequency Page 136</title><description>Electrical formulas Formulas Required conductor cross section for electric cables given Voltage drop, current Voltage drop, power Voltage drop, current Voltage drop, voltage Key: I γ L P po = = = = = Current in ampère Conductivity (copper 56, aluminium 34) Conductor lengths (single) in meters Transmission power in watts Powerlossin%ofthetransmissionpower A uo U cos ϕ = = = = Conductor cross section in mm2 Voltagedropin%oftheoperatingvoltage Operating voltage in volts Power factor (usually assumed to be 0.8) Direct current 200 · L · I γ · u0 · U 200 · L · P γ · u 0 · U2 200 · L · I2 γ · p0 · P 200 · L · P γ · p0 · U2 Single phase alternating current 200 · L · I · cosϕ γ · u0 · U 200 · L · P γ · u 0 · U2 200 · L · I2 γ · p0 · P 200 · L · P γ · p0 · U2 · cos2ϕ Three phase alternating current 173 · L · I · cosϕ γ · u0 · U 100 · L · P γ · u0 · U2 300 · L · I2 γ · p0 · P 100 · L · P γ · p0 · U2 · cos2ϕ The formulas stated for alternating and three-phase current do not give any consideration to the inductive resistance. This resistance is a function of the distance of the individual conductors between one another. Determination of the current if the power is known. Direct current: I P U l η = = = = = P U·η Rated power in W Voltage in V Current in A Efficiency Example: What is the current that a heating unit of 3.4 kW absorbs at 440 V ? (η = 1) I= 3400 440 · 1 = 7.7 A Alternating current: l P U l cos ϕ η = = = = = = P U · cosϕ · η Rated power in W Voltage in V Current in A Phase shift Efficiency P 1.73 · cosϕ · η · U Nennleistung in W Aussenleiterspannung in V Aussenleiterstrom in A Phasenverschiebung Wirkungsgrad Example: What is the current consumption of an alternating current motor of 1.9 kW at cos ϕ = 0.77 and an efficiencyof79%? The voltage is 230 V, 50 Hz. 1900 I = 230 · 0.77 · 0.79 = 13.6 A Three phase current: l P U l cos ϕ η = = = = = = Example: What current does a three phase motor of 22 kW consume at 400 V, 50 Hz, with cos ϕ = 0,89 and an efficiencyof90%? I= 22000 1.73 · 400 · 0.89 · 0.9 39.7 A 136 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=137</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=137</link><title>HUBER+SUHNER   Low Frequency Page 137</title><description>Table of three phase current Permissable three phase cable loading at 5% voltage drop Presentation: I = F(L) und I = F(P) cos ϕ = 0.82 A 350 I = F(P) mm2 300 240 250 225 200 150 185 150 125 120 Permissable fuse rating for fixed installation 95 100 80 60 50 40 20 10 L= P= 50 25 100 50 150 75 200 100 250 125 300 150 350 175 400 200 450 70 50 35 25 16 10 500 m KW Example: A power of 70 kW is to be transmitted across a distance of L = 450 m. The funktion I = F(P) gives us 70 kW ~= 130 A (mixed users). The function I = F(L) provides the cable cross section of 95 mm2. A length of 500 metres would already require a cable of 120 mm2 to ensure that the voltage loss and therefore also the power loss would be in an acceptable and economical range. Representation: I = F(L) shows that, for example, for 95 mm2 the permissable fuse of 200 A determines the load limit up to L = 300 m, i.e. UV&lt;5%. From 300 mm2 the cross section can no longer be fully utilized. HUBER+SUHNER 137 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=138</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=138</link><title>HUBER+SUHNER   Low Frequency Page 138</title><description>Characteristics of materials Typical characteristics of various insulation and jacket materials for cables Insulation compounds Thermoplastics Abbreviations (1) CENELEC type Thermical characteristics Thermal resistance 20’000 h (°C) 24 h (°C) Short circuit (°C) Resistance to cold, moved (°C) Mechanical characteristics Tensile strenght (N/mm2) Elongationatbreak(%) Abrasion resistance Flexibilty (2) Electrial characteristics Volume resistivity at 20°C(Ωcm) Dielectric constant at 1 kHz Fire characteristics Flame retardant Halogen free Corrosive combustion gases Smoke generation Resistance to Ionizing radiation (kGy) Solvents (3) Oils and fuels (3) Acids and alkaline solutions (3) Water/hydrolysis (3) Weather/UV radiation 100 satisf. satisf. good good good 1000 satisf. satisf. 1000 good good 1000 good good satisf. satisf. good 2000 100 1 2000 1000 satisf. satisf. 1000 satisf. satisf. 1000 good good good 1000 satisf. satisf. good 1000 500 yes no yes strong no yes no yes yes no no yes no yes no yes yes no yes low yes no yes low no yes no average no yes no yes yes no yes no yes strong yes no yes strong yes no yes low ja ja no average 1014 5.0 1016 2.3 1015 3.7 1015 3.8 1016 2.6 1018 2.2 1018 2.0 1015 3.0 1016 2.4 1014 4.2 1016 2.6 1016 2.8 1014 5.7 1015 3.0 ≥12.5 ≥125 satisf. satisf. ≥10 ≥300 good poor ≥25 ≥200 good poor ≥30 ≥200 ≥30 ≥150 ≥10 ≥200 ≥20 ≥200 satisf. poor ≥5.0 ≥200 satisf. very good Crosslinked materials PBT-FR TPE-E ETFE FEP PTFE EPR EI6 PE-X RX 125 RX 155S RX 155 PVDF-X SIR EI2 PVC TI1 PE 70 100 160 –5 70 100 100 –55 110 160 160 –40 110 160 160 –40 135 220 250 –55 180 240 250 –55 250 300 300 –70 90 180 250 –40 90 180 250 –55 120 200 250 –40 130 220 250 –55 135 220 250 –55 135 220 300 -55 180 260 350 -55 ≥12.5 ≥200 ≥12.5 ≥200 ≥12.5 ≥200 ≥15 ≥300 ≥28 ≥200 ≥5.0 ≥150 very good very good satisf. very good good very good good very good poor poor poor poor poor satisf. poor satisf. poor very good average average average low average low very good very good very good satisf. very good very good very good poor very good very good very good very good satisf. very good satisf. very good satisf. very good satisf. very good satisf. very good very good good very good good very good very good very good good very good very good very good good very good very good very good very good poor good satisf. good good good very good very good (1) RX = RADOX®, for other abbreviations see following page "Material designations" (2) depends greatly on cable construction (3) influenced by type, time and medium temperature Important: As the characteristics of compounds may vary widely according to their specific formulation, the values stated in the table must be understood as approximate values referring to typical representatives of their material class. The data is based on laboratory investigations and practical experience. It is stated to the best of our knowledge, but without guarantee. We will gladly advise you in individual cases. 138 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=139</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=139</link><title>HUBER+SUHNER   Low Frequency Page 139</title><description>Characteristics of materials Typical characteristics for cables Sheat compounds Thermoplastics Abbreviation (1) LSFH CENELEC type Thermical characteristics Thermal resistance 20’000 h (°C) 24 h (°C) Short circuit (°C) Resistance to cold, moved (°C) Mechanical characteristics Tensile strenght (N/mm2) Elongationatbreak(%) Abrasion resistance Flexibilty (2) Electrial characteristics Volume resistivity at 20°C(Ωcm) Dielectric constant at 1 kHz Fire characteristics Flame retardant Halogen free Corrosive combustion gases Smoke generation Resistance to Ionizing radiation (kGy) Solvents (3) Oils and fuels (3) Acids and alkaline solutions (3) Water/hydrolysis (3) Weather/UV radiation 1000 poor poor satisf. satisf. satisf. 5000 satisf. good satisf. 500 satisf. good 1000 satisf. satisf. 1000 satisf. good good good good 1000 satisf. good 1000 satisf. 1000 satisf. yes yes no low no yes no average Crosslinked materials CR EM2 RX 125A RX 125M RX 125TM REMS REMS FH TPU TMPU 90 130 250 –25 ≥9.0 ≥125 good satisf. 90 140 200 –55 ≥25 ≥300 60 120 200 –25 ≥10 ≥300 120 200 280 –25 ≥10 ≥125 good 120 200 280 –25 ≥9 ≥125 good good 120 200 280 –25 ≥10 ≥125 good good 130 200 280 –40 ≥15 ≥300 good good 120 200 280 –25 ≥10 ≥125 good good very good good satisf. very good satisf. 1013 5 1012 7 1010 8 1014 4.8 1012 6 1012 5 1012 4.8 1012 5.5 yes no yes stark yes yes no low yes yes no low yes yes no low yes no yes stark yes yes no low very good very good very good good very good very good good very good good good good very good good good good good good very good good (1) RX = RADOX®, for other abbreviations see following page "Material designations" (2) depends greatly on cable construction (3) influenced by type, time and medium temperature Important: As the characteristics of compounds may vary widely according to their specific formulation, the values stated in the table must be understood as approximate values referring to typical representatives of their material class. The data is based on laboratory investigations and practical experience. It is stated to the best of our knowledge, but without guarantee. We will gladly advise you in individual cases. Technical information HUBER+SUHNER 139</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=140</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=140</link><title>HUBER+SUHNER   Low Frequency Page 140</title><description>Colour table • • • • • • • BK TQ WH BN BU RD YE = = = = = = = black/schwarz turquoise/türkis white/weiss brown/braun blue/blau red/rot yellow/gelb • • • • • GN GY OG VT PK = = = = = = green/grün grey/grau orange/orange violet/violett pink/rosa green-yellow/grün-gelb • GNYE Material designations Thermoplastics ETFE FEP LSFHTM PBT FR PE PTFE PVC TPC TPU Crosslinked materials CR EPR PE-X PVDF-X RADOX® 125 RADOX® 125A RADOX® 125M RADOX® 125TM RADOX® 155 RADOX® 155S RADOX® ELASTOMER S (REMS) RADOX® ELASTOMER S FH (REMS FH) SIR ETFE-X Ethylene-tetrafluoroethylene copolymer Tetrafluoroethylene-perfluoropropylene copolymer Halogen free, flame retardant material (low smoke free of halogen) Flame retardant polybutylene terephthalate Polyethylene Polytetrafluoroethylene Polyvinylchloride Thermoplastic polyester elastomers Thermoplastic polyurethane Chloroprene rubber Ethylene propylene rubber Crosslinked polyethylene Crosslinked polyvinylidene fluoride Polyolefin copolymer Polyolefin copolymer Polyolefin copolymer Ethylene acrylate copolymer Polyolefin copolymer Polyolefin copolymer Ethylene acrylate copolymer Ethylene acrylate copolymer Silicon rubber Crosslinked Ethylene tetrafluorethylene RADOX® is a registered trademark of HUBER+SUHNER for electron beam crosslinked, heat resistant cable insulations and sheaths. LSFHTM is a registered trademark of HUBER+SUHNER for halogen free, flame retardant cable sheaths. 140 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=141</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=141</link><title>HUBER+SUHNER   Low Frequency Page 141</title><description>Core colours VDE 0293-308 / HD 308 S2 vs. HD 308 Example Core numbers: New HD 308 S2 Old HD 308 with yellow-green grounding wire 3 4 5 3 4 5 Old SEV 1101, 1102 without yellow-green grounding wire 2 3 4 5 2 3 4 5 black brown blue grey yellow-green HUBER+SUHNER 141 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=142</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=142</link><title>HUBER+SUHNER   Low Frequency Page 142</title><description>Resistance to cold and heat Typical operating temperature ranges of different insulations and sheaths SIR PVDF-X PTFE RADOX® 155 RADOX® 155S RADOX® 125TM RADOX® ELASTOMER S (REMS) RADOX® ELASTOMER S FH (REMS FH) RADOX® 125M RADOX® 125A RADOX® 125 RADOX® eco-F FEP ETFE EPR PE-X LSFH TPU CR PBT-FR TPE-E PVC PE –50°C Key: Resistance to cold moved 0°C +50°C +100°C +150°C +200°C +250°C +300°C 350°C Resistance to heat 20’000 h 24 h short circuit 142 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=143</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=143</link><title>HUBER+SUHNER   Low Frequency Page 143</title><description>Standards System for type designation of electric cables according to CENELEC HD 361 Example: light weight PVC sheathed cable, flat Block 1 H 03 V V Block 2 H – F 2 Block 3 X 0.75 1 2 3 4 5 6 7 8 9 Block 1: 1 H: A: 2 01: 03: 05: 07: Type of standard Harmonised type Acknowledged national type Voltage rating UO/U 100/100 V 300/300 V 300/500 V 450/750 V 5 Construction feature H: flat, divisible line H2: flat, non-divisible line 6 F: H: K: R: U: Conductor type stranded (class 5) with flexible cables stranded (class 6) with flexible cables stranded (class 5) with permanently installed cables stranded (class 2) solid (class 1) Block 2: 3 R: G: N: Q: R: S: V: V2: V3: V5 Z: 4 Sheat material Insulation material Ethylen propylen rubber, 90 °C Ethylen vinylacetat Polychloropren rubber Polyurethane Ethylen propylen rubber, 60 °C Silicon rubber PVC PVC, 90 °C PVC, cold resistant PVC, oil resistant Crosslinked polyolefin compound, little corrosive gases, low smoke Z1: Thermoplastic polyolefin compound, little corrosive gases, low smoke Block 3: 7 Number of cores 8 Protective earth conductor X: without protecitve earth conductor (yellow-green) G: with protecitve earth conductor (yellow-green) 9 Conductor cross section in mm2 HUBER+SUHNER 143 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=144</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=144</link><title>HUBER+SUHNER   Low Frequency Page 144</title><description>Conversion AWG Metric wire cross sections and wire diameters AWG = American Wire Gauge AWG Cross section mm2 nom. 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 0.013 0.020 0.032 0.051 0.081 0.13 0.21 0.32 0.52 0.82 1.3 2.1 3.3 5.3 8.4 13 21 27 34 42 54 67 85 107 with UL/CSA Diameter mm nom. 0.13 0.16 0.20 0.25 0.32 0.40 0.51 0.64 0.81 1.0 1.3 1.6 2.1 2.6 3.3 4.1 5.2 5.8 6.5 7.3 8.3 9.3 10 12 with MIL Cross section mm2 nom. – – – 0.057 0.090 0.15 0.24 0.38 0.62 0.96 1.2 1.9 3.0 4.7 8.6 14 22 – 34 41 53 67 84 107 Thermal classes of insulating materials according to EN 60085 Thermal class Y A E Max. limitingtemperature 90 °C 105 °C 120 °C Thermal class B F H Max. limitingtemperature 130 °C 155 °C 180 °C Thermal class 200 220 250 Max. limitingtemperature 200 °C 220 °C 250 °C 144 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=145</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=145</link><title>HUBER+SUHNER   Low Frequency Page 145</title><description>Wire cross section according to EN 60228 and CENELEC HD 383 table 1 Nom. cross section mm2 0.5 0.75 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Construction: number of wires (approximate value) strand diameter (maximum) solid, class 1 n x mm 1 x 0.80 1 x 1.00 1 x 1.13 1 x 1.38 1 x 1.78 1 x 2.25 1 x 2.76 1 x 3.57 1 x 4.50 – – – – – – – – – – – – – stranded, class 2 n x mm 7 x 0.30 7 x 0.37 7 x 0.43 7 x 0.52 7 x 0.67 7 x 0.85 7 x 1.04 7 x 1.35 7 x 1.70 7 x 2.16 7 x 2.52 19 x 1.78 19 x 2.16 19 x 2.52 37 x 2.03 37 x 2.25 37 x 2.52 61 x 2.25 61 x 2.52 61 x 2.84 61 x 3.20 91 x 2.97 max. direct current at 20 °C bare Ω/km 36.0 24.5 18.1 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 tinned Ω/km 36.7 24.8 18.2 12.2 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 0.0475 0.0369 0.0286 Terminals: Because of the larger diameter in classes 2, 5 and 6 compared with class 1, you have to select a terminal for these classes that is one nominal cross section larger. HUBER+SUHNER 145 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=146</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=146</link><title>HUBER+SUHNER   Low Frequency Page 146</title><description>Wire cross sections according to EN 60228 and Cenelec HD 383 table 2 Nom. cross section mm2 0.5 0.75 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Construction: number of wires (approximate value) strand diameter (maximum) stranded, class 5 n x mm 19 x 0.21 24 x 0.21 32 x 0.21 30 x 0.26 50 x 0.26 56 x 0.31 80 x 0.31 77 x 0.41 123 x 0.41 190 x 0.41 266 x 0.41 385 x 0.41 348 x 0.51 468 x 0.51 589 x 0.51 741 x 0.51 912 x 0.51 1184 x 0.51 1480 x 0.51 1961 x 0.51 1702 x 0.61 2146 x 0.61 stranded, class 6 n x mm 25 x 0.16 38 x 0.16 50 x 0.16 75 x 0.16 125 x 0.16 200 x 0.16 174 x 0.21 290 x 0.21 462 x 0.21 722 x 0.21 1012 x 0.21 664 x 0.31 928 x 0.31 1260 x 0.31 1590 x 0.31 1990 x 0.31 2452 x 0.31 3180 x 0.31 3976 x 0.31 – – – max. direct current at 20 °C bare Ω/km 39.0 26.0 19.5 13.3 7.98 4.95 3.30 1.91 1.21 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.0801 0.0641 0.0486 0.0384 0.0287 tinned Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 0.0391 0.0292 146 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=147</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=147</link><title>HUBER+SUHNER   Low Frequency Page 147</title><description>Guide to installation Smallest allowable bending radii for power and signal cables Conductor type Installation method solid, class 1/stranded, class 2 – carefully bent at connection – normal use stranded, class 5 (HUBER+SUHNER) – fixed – flexing 3D 4D 3D 4D 4D 5D 4D 6D 2D 4D 3D 5D 4D 6D 4D 6D D≤8 Cable diameter D (mm) 8&lt;D≤12 12&lt;D≤20 D &lt; 20 Allowable tensile stress 1. For installing cables by pulling on the conductors, or by drawing sleeve, the following max. pulling force (P) is allowed: P = 50 x A (N) A = Sum of conductor cross section (mm2) 2. When installing cables with high tensile armouring, the following max. pulling force (P) is allowed: P = 9 x D2 (N) D = cable diameter over armouring (mm) The calculation of pulling forces necessary for installation is done using the following formulas: Pulling force for installation of a straight section without elevation difference. P= with P: G: L: μ: 10xGxLxμ pulling force at the end of the stretch (N) weight of the cable (kg/m) length of the section (m) coefficientoffriction with 0.15 – 0.30 0.40 – 0.60 0.15 – 0.25 0.15 – 0.30 Pulling force for installation of a straight section with elevation difference P= 10xGx(Lxμ±h) h: elevation difference (m) Frictioncoefficientμ installation with rollers installation in cement pipes installation in plastic pipes – with special lubricating grease – with water N.B.: Very long cables with thermoplastic sheaths can be pulled into plastic pipes with the aid of lubricants only. Local heating, occurring mainly in bends, may cause the cable to stick to the pipe wall. HUBER+SUHNER 147 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=148</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=148</link><title>HUBER+SUHNER   Low Frequency Page 148</title><description>Delivery spools l1 l2 d2 d3 Spool type One way spools Nr. 5 d1 d2 d3 l1 l2 Tara kg Cable dia mm 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 45 48 140 65 60 56 50 0.08 Nr. 6 140 65 60 106 100 0.10 Nr. 7 170 65 60 135 130 0.15 DIN 250 250 160 22 200 160 0.71 L 355 355 200 36 160 150 1.54 L 450/13 450 200 50 244 228 2.48 L 450/14 450 312 50 244 228 3.02 L 500 500 250 50 321 305 3.16 LHL 710 710 360 82 430 400 10 LHL 900 900 450 82 545 450 36 LHL 1050 1050 550 82 698 600 53 LHL 1250 1250 700 92 726 630 74 LHL 1400 1400 700 92 880 760 120 LHL 1600 1600 800 92 1025 900 174 Cable length per delivery spool m 970 2020 500 3710 930 8100 2030 510 220 5820 1450 650 360 230 940 420 230 150 2240 1000 560 360 250 180 140 110 5880 2610 1470 940 650 480 370 290 230 4770 2680 1720 1190 880 670 530 430 350 300 250 220 190 170 150 130 120 8380 4710 3010 2090 1540 1180 930 750 620 520 450 380 330 290 260 230 210 190 150 130 1060 880 740 630 540 470 410 370 330 290 260 210 180 1750 1450 1220 1040 890 780 680 610 540 490 440 350 300 2710 2240 1880 1610 1380 1210 1060 940 840 750 680 540 470 148 d1 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=149</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=149</link><title>HUBER+SUHNER   Low Frequency Page 149</title><description>EMC screened cables The screening of cables can be described by the two coupling quantities of transfer impedance ZT and transfer admittance YT. Both coupling quantities are basically a function of the geometry and the environment; depending on the specific application and requirements, the coupling quantities can be optimised for a given cable. EMI EMP ESD LEMP NEMP TEMPEST NEXT electromagnetic interference electromagnetic pulse electrostatic discharge lightning electromagnetic pulse nuclear electromagnetic pulse tap-proofness (eaves-dropping protection) near end crosstalk With HUBER+SUHNER, your screening problems will end. We can ensure this thanks to the vast experience accumulated in this field responding to every kind of customer need and collaborating continuously with research institutes. Measurement engineering at HUBER+SUHNER Complies with the following standards: IEC 96-1 and 46 A/DIN 47250/ VG 95373/CCITT/. Screenings for all EMC requirements HUBER+SUHNER designs, optimises and produces products for a wide variety of performance classes. These products are implemented using different braids, foils, high-permeability intermediate layers, microwave absorbing and semi-conducting layers, mixed screens, etc. HUBER+SUHNER 149 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=150</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=150</link><title>HUBER+SUHNER   Low Frequency Page 150</title><description>EMC screened cables Screened cables from single braid to superscreen Transfer impedance values of single braid screening Approximate values 1 ZT 2 100m Ω) (m 5 2 10m 5 2 1m 5 2 100µ 5 2 10µ 5 2 1µ D= 1mm 3mm 8mm 15mm Transfer impedance values of superscreen Approximate values 1 ZT 2 100m Ω) (m 5 2 10m 5 2 1m 5 2 100µ 5 2 10µ 5 2 1µ D= 1mm 3mm 8mm 15mm 2 4 68 2 4 68 2 4 68 2 4 68 2 4 68 1K 10K 100K 1M 10M 100M 2 4 68 2 4 68 2 4 68 2 4 68 2 4 68 1K 10K 100K 1M 10M 100M f (Hz) Transfer impedance values ZT as a function of the frequency f and the cable diameter D as parameters f (Hz) Transfer impedance ZT as a function of the frequency f and of the cable diameter D as parameters The transfer impedance ZT (also called “coupling resistance”) refers to the relationship between the current in one wire and the longitudinal voltage it induces in the other wire (ohmic-inductive coupling) Definition of transfer impedance ZT i2 Outer conductor Inner conductor The transfer admittance YT refers to the relationship between the voltage in one wire and the leak current it induces in the other line (capacitive coupling). Definition of transfer admittance YT u1 l ZT = u1 i2 · l [Ω/m] YT = i1 u2 · l [S/m] i2 i2 l V i2 u1 A u2 V l i1 The cable together with its surroundings form a threeconductor system. It consists of two coupled conductors with one common conductor (screen). Transfer impedance ZT and transfer admittance YT are cable quantities which are always defined in conjunction with the surroundings of the cable and the construction of the cable itself. 150 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=151</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=151</link><title>HUBER+SUHNER   Low Frequency Page 151</title><description>Protect your equipment and machinery from interference and failure Lightning protector (earth) Fluorescent lamp Computer Mains Radio set Main RF oven The situation Environmental pollution is a modern buzzword. But do you ever think of it as "pollution" by electromagnetic radiation, by "electrosmog"? Your problem Only when machinery starts to fail and plant operation is disrupted do the people in charge start thinking. But things don’t have to reach that point. Non-screened single braid optimised single braid + foil double braid optimised double braid cables act in the same way as antennas, attracting interference from the outside or radiating it. Our solution Copper braids prevent dangerous interferences with cables. At the same time, the interference radiated by the cable is reduced. Our solution consists not only in the specification of a degree of coverage. HUBER+SUHNER also defines the effectiveness of a copper braid as a measurable quantity. This noise immunity is expressed by the transfer impedance (coupling resistance)atagivenfrequency(MHz)inΩ/m. Optimized, high grade screening Optimized screening braids enable even the most intractable screening problems to be solved. And in screening cables, we take care to ensure that performance of the screened cables will not be significantly affected in terms of flexibility, workability, weight and dimensions. transfer impedance "pipe" frequency HUBER+SUHNER 151 Technical information 2nd braid + amorphous metal (superscreen)</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=152</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=152</link><title>HUBER+SUHNER   Low Frequency Page 152</title><description>Fire test methods Fire test methods for electrical wires and cables Designation Flame temperature Test duration Conditions EN 50265-2-1 IEC 60332-1 Determined by the prescribed adjustment of the flame. CablediaD≤25mm: 60s Cabledia25&lt;D≤50mm:120s The cable shall be self extinguishing. The damage by fire shall be more than 50 mm from the top fastening clamp. EN 50265-2-2 IEC 60332-2 Determined by the prescribed adjustment of the flame. 20 s The cable shall be self extinguishing. The damage by fire shall be more than 50 mm from the top fastening clamp. 180 125 600 600 45° 100 55 45° Designation Flame temperature Test duration Conditions EN 50266-2-4 IEC 60332-3-24 Determined by the prescribed propane gas and air volumes. Cat. A (7 l compustible material): 40 min. Cat. B (3.5 l compustible material): 40 min. Cat. C (1.5 l compustible material): 20 min. The damage by fire shall be maximum 2.5 m from the lower burner end. 100 NF C32-070 test 2 UIC 895 VE appendix 7 830 ± 50 °C. 30 min. The cable piece projecting from the pipe shall be not damaged. fan 10 min. 250 3500 pipe dia 125 1600 75 800 30 ignition flame oven 500 air 100 air air 152 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=153</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=153</link><title>HUBER+SUHNER   Low Frequency Page 153</title><description>Fire test methods Fire test methods for electrical wires and cables Designation Flame temperature Test duration MIL-W-22759 and MIL-W-81044 VG 95218-2 procedure 4 min. 950 °C 30 s The specimen shall not continue to burn for more than 30 s, and damage by fire shall not exceed 76 mm. Dripping material shall not ignite the tensioned tissue paper (S). VG 95218-2 procedure 3 Determined by the prescribed adjustment of the flame. CablediaD≤25mm: Cabledia25&lt;D≤50mm: 60s 120s Conditions The specimen shall not continue to burn for more than 30 s, and damage by fire shall not exceed 76 mm. Dripping material shall not ignite the tensioned tissue paper (S). 18 0 25 G 75 20 250 13 125 250 455 230-240 55 0 45° 45° 60 0 0 10 250 60° S 30° S Designation Flame temperature Test duration UL 1581 section 1090 Horizontal specimen AWM flame test Determined by the prescribed adjustment of the flame. 30 s The rate of the flame propagation shall not exceed 25 mm/min. Dripping material shall not ignite the cotton wool underneath (B). 13 UL 1581 section 1061 UL 1581 section 1080 (VW1) Determined by the prescribed adjustment of the flame. Sect.1061: 60 s flaming, 30 s pause (3x) Sect.1080: 15 s flaming, 15 s pause (5x) Thepapershallnotbeburnedmorethan25%, and the specimen shall not continue to burn for more than 60 s. Dripping material shall not ignite the cotton wool underneath (B). Papier 10 x 20 Conditions 50 230-240 17 40 20° B 50-75 B HUBER+SUHNER 153 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=154</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=154</link><title>HUBER+SUHNER   Low Frequency Page 154</title><description>Fire test methods Fire test methods for electrical wires and cables Designation Flame temperature Test duration IEC 60331-21, IEC 60331-23 DIN VDE 0472-814 BS 6387, category C IEC, DIN VDE: min. 750 °C BS : 950 ± 40 °C. IEC: 90 min. recommended DIN VDE, BS: 180 min. Zwischen den Adern wird eine Prüfspannung angelegt. IEC: power cable: UO/U IEC, DIN VDE: data cable: 110 V DIN VDE: power cable: 230/400 V BS: all UO/U The fuses shall not blow and the incandescent lamps shall not extinguish. BS 6387, category W 650 ± 40 °C 30 min. A test voltage is applied between the cores which equals the mains voltage UO/U. After 15 min. exposure to the flame, the sprinkler is additionally switched on. The fuses shall not blow and the incandescent lamps shall not extinguish. Conditions R S T 3A holder 75 1200 20 350 0 150 Designation Flame temperature Test duration Conditions EN 50267-2-2 IEC 60754-2 min. 935 °C 30 min. EN 50268-2 IEC 61034-2 Determined by the composition of the combustion liquid. 40 min. The pH value of the washing water shall be min. The light permeability of the resulting 4.3, its conductivity shall not exceed smokeshallbemin.60%. 10μS/mm. 1000 test chamber height=3000 mm oven synth. air gas washing bottles lamp specimen 1 g fan photocell unit 3000 154 HUBER+SUHNER 3000 cable trouh with combustion liquid recirculation air screening</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=155</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=155</link><title>HUBER+SUHNER   Low Frequency Page 155</title><description>Current carrying capacity of RADOX® 125 single core and multi core cables Scope The following tables referring to RADOX® connecting leads and multicore cables give easy and fast support for the layout of apparatus and components. The following remarks are based on today’s state of the art and practical experience as described in the standard IEC 60216, IEC 60287 and IEC 60364. The application of products will frequently vary from the theoretical values of constant ambient temperature, constant current carrying, homogeneous laying and others. That means, in practice the theoretical current carrying will differ from the real values. For a safe layout of apparatus and components it is recommended to carry out a test with the installed connecting lead or cable under service conditions. Definitions Current load Continuous operation Current rating Permissible operating temperature Wire Cable Conductor temperature current passed through the cable during operation an operation with constant current whose duration is at least long enough to allow the system to reach thermal equilibrium, but may then go on indefinitely maximum permissible current under determined operating maximum permissible temperature on the condutor in continuous operation insulated single core bundle with jacket with one ore more insulated single cores temperature of the surface of the core material General remarks The current rating of a cable depends on the conductor cross section, on the cable design, on the characteristics of the insulation materials, on the installation conditions and, for larger cross sections, on the frequency (skin and proximity effects). Also, additional heating effects due to higher ambient temperatures, due to heating elements and due to bunching of cables have to be taken into account. The conductor cross section has to be selected in such a way that the actual current load does not exceed the curent rating, i.e. the conductor temperature does not exceed the permissible operating temperature. The determining factor is the appropriate, most unfavourable operating condition, encountered during operation over the whole length of the cable. Current rating under service conditions (I [A]) I = IN•f1•f2•f3•f4•f5 I [A] IN[A] f1 f2 f3 f4 f5 Current rating for continuous operation under service conditions Current rating for continuous operation under standard conditions Reduction factor for increased ambient temperature Conversion factor for deviated conductor temperature, acc. to. temperature index, IEC 60216 (20'000 h) Reduction factor for multicore cables Reduction factor for increased frequency Reduction factor for bundeled cables HUBER+SUHNER 155 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=156</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=156</link><title>HUBER+SUHNER   Low Frequency Page 156</title><description>Current carrying capacity of RADOX® single core and multi core cables Standard conditions for current rating (IN [A]) The tabled values for the current rating were calculated according to IEC 60287 for the following standard conditions: • continuous operation • single circuit for 3-phase current, single conductor for 1-phase current • 30°C ambient temperature and sufficiently large and ventilated spaces, whose ambient temperature is not appreciably increased by the heat coming from the cables. • 120 °C conductor temperature • frequency up to 200 Hz Installation in air, unrestricted heat dissipation, means that the following installation conditions are observed: • distance of the cables from the wall, from the floor, from the ceiling &gt; cable diameter • distance between two adjacent power circuits &gt; 2 x cable diameter • vertical distance between power circuits laid one upon another for individual cables &gt; 2 x cable diameter and for layers of cables &gt; 200 mm • perforatedtraywithaperforation&gt;30%ofthetotalsurface Opentraysarecontinuoussupportswithverticalsides,butwithoutcover.Apossibleperforationaccountsfor&lt;30% of the total surface. Closedductsareentirelyclosed.Pipesbelongtothiscategoryalso.Themax.fillingdegreeis60%. Maximum permitted conductor temperature for various insulating materials according to IEC 60216 (20'000h/50%elongationatbreak): PVC, CR PE-X, EPR RADOX® 125 RADOX® 155 70 °C 90 °C 120 °C 135 °C Life time expectation If crosslinked wires are used at higher temperatures than indicated by the temperature index of IEC 60216, the life time is reduced accordingly. Analogical, the life time will increase at lower temperature. RADOX® 125 for example has a life span of 20'000 h at a conductor temperature of +120 °C, which is approx. 2.5 years. If it is used at another temperature, life time expectations are as follows: Example RADOX® 125, d.h. 120 °C / 20'000 h 160 °C 150 °C 140 °C 130 °C 120 °C 110 °C 100 °C 90 °C 80 °C 1'250 h 2'500 h 5'000 h 10'000 h 20'000 h 40'000 h 80'000 h 160'000 h 320'000 h 156 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=157</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=157</link><title>HUBER+SUHNER   Low Frequency Page 157</title><description>Current carrying capacity of RADOX® single core and multi core cables Reduction factors for increased ambient temperature (f1) Ambient temp. [°C] Reduction factor f1 30 1 35 0.97 40 0.94 45 0.91 50 0.88 55 0.85 60 0.82 65 0.78 70 0.75 75 0.71 80 0.67 85 0.62 90 0.58 95 0.53 100 0.47 105 0.41 110 0.33 115 0.22 Reduction factors for different permissible conductor temperature (f2) Conductor temp. (°C) Reduction factor f2 135 1.04 120 1 110 0.96 100 0.91 90 0.85 80 0.79 Reduction factors for multicore cables (f3) No. of cores in cable Reduction factor f3 3 1.0 4 0.80 5 0.75 7 0.65 8 0.62 10 0.55 14 0.50 16 0.48 19 0.45 20 0.44 24 0.40 27 0.39 33 0.37 40 0.35 61 0.30 Reduction factors for increased frequency (f4) Frequency [Hz]* Copper conductor cross section mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 1 1 1 1 1 1 1 1 1 1 0.98 0.94 0.90 0.88 0.85 0.79 0.75 1 1 1 1 1 1 1 1 1 0.95 0.93 0.88 0.85 0.82 0.77 0.73 0.69 1 1 1 1 1 1 1 1 0.97 0.91 0.88 0.84 0.80 0.77 0.72 0.69 0.65 1 1 1 1 1 1 1 0.98 0.94 0.88 0.84 0.80 0.77 0.74 0.69 0.66 0.63 400 600 800 1000 2000 faktors f4 1 1 1 1 1 1 0.94 0.89 0.83 0.77 0.73 0.69 0.66 0.64 0.60 0.57 0.54 3000 4000 5000 10000 1 1 1 1 1 0.95 0.88 0.82 0.76 0.71 0.67 0.64 0.61 0.58 0.54 0.52 0.49 1 1 1 1 0.96 0.91 0.83 0.77 0.72 0.67 0.63 0.60 0.57 0.54 0.51 0.48 0.46 1 1 1 0.99 0.93 0.87 0.80 0.74 0.69 0.63 0.60 0.57 0.54 0.52 0.48 0.46 0.44 1 1 0.98 0.93 0.82 0.76 0.69 0.64 0.59 0.54 0.51 0.48 0.46 0.44 0.41 0.39 0.37 * We recommend that you use a special conductor design for frequencies &gt; 800 Hz and cross sections &gt; 25 mm2 (waveguide design). HUBER+SUHNER 157 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=158</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=158</link><title>HUBER+SUHNER   Low Frequency Page 158</title><description>Current carrying capacity of RADOX® single cores Installation method Connecting lead in free air or perforated tray ≥d Number of simultaneous loaded conductors on each tray Reduction factor f5 Copper conductor cross section mm2 0.50 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 ≥d 1 1 2 0.87 3 0.81 4 0.78 6 0.75 8 0.74 10 0.73 16 0.72 20 0.71 4 0.71 6 0.62 Current carrying capacity in [A] 19 24 29 36 49 66 85 121 163 219 272 344 439 523 621 723 825 996 1150 1473 16.4 20.8 24.8 31 43 57 74 105 142 191 237 299 382 455 540 629 718 867 1001 1282 15.3 19.4 23.1 29 40 53 69 98 132 177 220 279 356 424 503 586 668 807 932 1194 14.7 18.6 22.2 28 38 51 67 94 127 171 212 268 342 408 484 564 644 777 897 1149 14.2 17.9 21.4 27 37 49 64 91 122 164 204 258 329 392 466 542 619 747 863 1105 14.0 17.7 21.1 26 36 49 63 90 121 162 201 255 325 387 460 535 611 737 851 1091 13.8 17.4 20.8 26 36 48 62 88 119 160 199 251 320 382 453 528 602 727 840 1076 13.6 17.2 20.5 26 35 47 61 87 117 158 196 248 316 377 447 521 594 717 828 1061 13.4 17.0 20.2 25 35 47 61 86 116 155 193 244 312 371 441 513 586 707 817 1046 13.4 17.0 20.2 25 35 47 61 86 116 155 193 244 312 371 441 513 586 707 817 1046 11.7 14.8 17.7 22 30 41 53 75 101 136 169 213 272 324 385 448 512 618 713 914 158 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=159</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=159</link><title>HUBER+SUHNER   Low Frequency Page 159</title><description>Continuous current rating conductor temperature 120 °C, ambient temperature 30 °C 8 0.57 10 0.53 16 0.47 20 0.45 4 0.67 6 0.59 8 0.54 10 0.50 16 0.45 20 0.43 4 0.71 6 0.58 8 0.52 10 0.48 16 0.41 20 0.38 10.8 13.6 16.2 20 28 38 49 69 93 125 155 196 250 298 354 412 470 568 656 840 10.0 12.7 15.1 19 26 35 45 64 86 116 144 182 233 277 329 383 437 528 610 781 8.9 11.2 13.4 17 23 31 40 57 77 103 128 162 206 246 292 340 388 468 541 693 8.5 10.8 12.8 16 22 30 38 54 73 99 122 155 198 235 279 325 371 448 518 663 12.7 16.0 19.1 24 33 44 57 81 109 147 182 230 294 350 416 484 553 667 771 987 11.2 14.1 16.8 21 29 39 50 71 96 129 160 203 259 309 366 427 487 588 679 870 10.2 12.9 15.4 19 26 36 46 65 88 118 147 186 237 282 335 390 446 538 621 796 9.5 12.0 14.3 18 24 33 43 61 82 110 136 172 220 262 311 362 413 498 575 737 8.5 10.8 12.8 16 22 30 38 54 73 99 122 155 198 235 279 325 371 448 518 663 8.1 10.3 12.3 15 21 28 37 52 70 94 117 148 189 225 267 311 355 428 495 634 13.4 17.0 20.2 25 35 47 61 86 116 155 193 244 312 371 441 513 586 707 817 1046 11.0 13.9 16.5 21 28 38 49 70 95 127 158 200 255 303 360 419 479 578 667 855 9.8 12.4 14.8 19 25 34 44 63 85 114 141 179 228 272 323 376 429 518 598 766 9.1 11.5 13.7 17 23 32 41 58 78 105 131 165 211 251 298 347 396 478 552 708 7.7 9.8 11.7 15 20 27 35 50 67 90 112 141 180 214 255 296 338 408 472 604 7.2 9.1 10.8 14 19 25 32 46 62 83 103 131 167 199 236 275 314 378 437 560 HUBER+SUHNER 159 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=160</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=160</link><title>HUBER+SUHNER   Low Frequency Page 160</title><description>Current carrying capacity of RADOX® single cores Installation method on floor or wall fixed on a ceiling or under floor or Number of simultaneous loaded conductors on each tray Reduction factor f5 Copper conductor cross section mm2 0.50 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 1 1 2 0.87 3 0.79 4 0.75 1 0.95 2 0.81 3 0.72 4 0.68 5 0.66 6 0.64 7 0.63 8 0.62 Current carrying capacity in [A] 18 23 27 34 46 63 81 115 155 208 258 327 417 497 590 687 784 946 1093 1352 15.3 19.3 23.0 29 39 53 69 98 132 177 220 278 354 422 501 584 666 804 929 1150 14.2 17.9 21.4 27 37 49 64 91 122 164 204 258 329 393 466 543 619 747 863 1069 13.5 17.0 20.3 25 35 47 61 86 116 156 194 245 313 373 442 515 588 710 819 1114 17.1 21.6 25.7 32 44 59 77 109 147 198 245 310 396 472 560 653 745 899 1038 1285 14.5 18.4 21.9 27 38 51 66 93 125 169 209 265 338 402 478 556 635 766 885 1096 12.9 16.3 19.5 24 33 45 58 83 111 150 186 235 300 358 425 495 564 681 787 974 12.2 15.4 18.4 23 32 43 55 78 105 141 176 222 284 338 401 467 533 643 743 920 11.9 15.0 17.9 22 31 41 53 76 102 137 171 216 275 328 389 453 517 624 721 893 11.5 14.5 17.3 22 30 40 52 74 99 133 165 209 267 318 378 440 502 606 699 866 11.3 14.3 17.1 21 29 39 51 72 98 131 163 206 263 313 372 433 494 596 688 852 11.1 14.1 16.8 21 29 39 50 71 96 129 160 203 259 308 366 426 486 587 677 839 160 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=161</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=161</link><title>HUBER+SUHNER   Low Frequency Page 161</title><description>Continuous current rating conductor temperature 120 °C, ambient temperature 30 °C in conduit, in a void or in a pipe ≥9 0.61 1 1 2 0.80 3 0.70 4 0.65 5 0.60 6 0.57 7 0.54 8 0.52 9 0.50 10 0.48 12 0.45 14 0.43 16 0.41 20 0.38 11.0 13.9 16.5 21 28 38 49 70 94 127 158 199 254 303 360 419 478 577 666 825 14.4 18.2 22 27 37 50 65 92 124 166 207 261 334 397 472 549 627 757 874 973 11.5 14.5 17.3 22 30 40 52 74 99 133 165 209 267 318 378 440 502 606 699 779 10.1 12.7 15.2 19 26 35 45 64 87 117 145 183 234 278 330 385 439 530 612 682 9.3 11.8 14.1 18 24 33 42 60 81 108 134 170 217 258 307 357 408 492 568 633 8.6 10.9 13.0 16 22 30 39 55 74 100 124 157 200 238 283 330 376 454 524 584 8.2 10.4 12.3 15 21 29 37 52 71 95 118 149 190 227 269 313 357 431 498 555 7.8 9.8 11.7 15 20 27 35 50 67 90 112 141 180 215 255 297 339 409 472 526 7.5 9.4 11.3 14 19 26 34 48 64 87 107 136 173 207 245 286 326 394 454 506 7.2 9.1 10.8 14 19 25 32 46 62 83 103 131 167 199 236 275 314 378 437 487 6.9 8.7 10.4 13 18 24 31 44 59 80 99 125 160 191 227 264 301 363 420 468 6.5 8.2 9.7 12 17 23 29 41 56 75 93 118 150 179 212 247 282 341 393 438 6.2 7.8 9.3 12 16 22 28 40 53 72 89 112 143 171 203 236 270 325 376 419 5.9 7.4 8.9 11 15 21 27 38 51 68 85 107 137 163 194 225 257 310 358 399 5.5 6.9 8.2 10 14 19 25 35 47 63 79 99 127 151 179 209 238 288 332 370 HUBER+SUHNER 161 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=162</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=162</link><title>HUBER+SUHNER   Low Frequency Page 162</title><description>Current carrying capacity of RADOX® multi core cables Installation method Multicore cables in free air or perforated trays Number of simultaneous loaded conductors on each tray Reduction factor f5 Copper conductor cross section mm2 0.50 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 ≥0.3d 1 1 2 0.87 3 0.81 4 0.78 6 0.75 8 0.74 10 0.73 16 0.72 20 0.71 4 0.71 6 0.62 Current carrying capacity in [A] 14.5 18.5 22 28 38 51 66 95 128 167 205 257 325 382 443 12.6 16.1 19.1 25 34 44 58 83 112 146 179 224 283 333 386 11.7 15.0 17.8 23 31 42 54 77 104 136 167 209 264 310 359 11.3 14.4 17.2 22 30 40 52 75 100 131 160 201 254 298 346 10.9 13.9 16.5 21 29 39 50 72 96 126 154 193 244 287 333 10.7 13.7 16.3 21 29 38 49 71 95 124 152 191 241 283 328 10.6 13.5 16.1 21 28 38 49 70 94 122 150 188 238 279 324 10.4 13.3 15.8 21 28 37 48 69 93 121 148 186 234 276 319 10.3 13.1 15.6 20 27 37 47 68 91 119 146 183 231 272 315 10.3 13.1 15.6 20 27 37 47 68 91 119 146 183 231 272 315 9.0 11.5 13.6 18 24 32 41 59 80 104 128 160 202 237 275 162 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=163</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=163</link><title>HUBER+SUHNER   Low Frequency Page 163</title><description>Continuous current rating conductor temperature 120 °C, ambient temperature 30 °C 8 0.57 10 0.53 16 0.47 20 0.45 4 0.67 6 0.59 8 0.54 10 0.50 16 0.45 20 0.43 4 0.71 6 0.58 8 0.52 10 0.48 16 0.41 20 0.38 8.3 10.5 12.5 16 22 30 38 55 73 96 117 147 186 218 253 7.7 9.8 11.7 15 21 28 35 51 68 89 109 137 173 203 235 6.8 8.7 10.3 14 18 24 32 45 61 79 97 121 153 180 209 6.5 8.3 9.9 13 18 23 30 43 58 76 93 116 147 172 200 9.7 12.4 14.7 19 26 35 45 64 86 112 138 173 218 256 297 8.6 10.9 13.0 17 23 31 39 57 76 99 121 152 192 226 262 7.8 10.0 11.9 16 21 28 36 52 70 91 111 139 176 207 240 7.3 9.3 11.0 14 19 26 33 48 64 84 103 129 163 191 222 6.5 8.3 9.9 13 18 23 30 43 58 76 93 116 147 172 200 6.2 8.0 9.5 13 17 22 29 41 56 72 89 111 140 165 191 10.3 13.1 15.6 20 27 37 47 68 91 119 146 183 231 272 315 8.4 10.7 12.8 17 23 30 39 56 75 97 119 150 189 222 257 7.5 9.6 11.4 15 20 27 35 50 67 87 107 134 169 199 231 7.0 8.9 10.6 14 19 25 32 46 62 81 99 124 156 184 213 5.9 7.6 9.0 12 16 21 28 39 53 69 85 106 134 157 182 5.5 7.0 8.4 11 15 20 26 37 49 64 78 98 124 146 169 HUBER+SUHNER 163 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=164</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=164</link><title>HUBER+SUHNER   Low Frequency Page 164</title><description>Current carrying capacity of RADOX® multi core cables Installation method on floor or wall fixed on a ceiling or under floor oder Number of simultaneous loaded conductors on each tray Reduction factor f5 Copper conductor cross section mm2 0.50 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 1 1 2 0.87 3 0.79 4 0.75 1 0.95 2 0.81 3 0.72 4 0.68 5 0.66 6 0.64 7 0.63 8 0.62 Current carrying capacity in [A] 13.5 17 20 26 35 48 62 88 116 154 190 239 299 351 405 11.5 14.5 17.0 23 30 41 53 75 99 131 162 204 255 299 345 10.7 13.4 15.8 21 28 38 49 70 92 122 151 189 237 278 320 10.1 12.8 15.0 20 27 36 47 66 87 116 143 180 225 264 304 12.8 16.2 19.0 25 34 46 59 84 111 147 181 228 285 334 385 10.9 13.8 16.2 22 29 39 51 72 94 125 154 194 243 285 329 9.7 12.2 14.4 19 26 35 45 64 84 111 137 173 216 253 292 9.2 11.6 13.6 18 24 33 43 60 79 105 130 163 204 239 276 8.9 11.2 13.2 18 24 32 41 59 77 102 126 158 198 232 268 8.6 10.9 12.8 17 23 31 40 57 75 99 122 153 192 225 260 8.5 10.7 12.6 17 23 31 40 56 74 98 120 151 189 222 256 8.4 10.5 12.4 17 22 30 39 55 72 96 118 149 186 218 252 164 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=165</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=165</link><title>HUBER+SUHNER   Low Frequency Page 165</title><description>Continuous current rating conductor temperature 120 °C, ambient temperature 30 °C in conduit, in a void or in a pipe ≥9 0.61 1 1 2 0.80 3 0.70 4 0.65 5 0.60 6 0.57 7 0.54 8 0.52 9 0.50 10 0.48 12 0.45 14 0.43 16 0.41 20 0.38 8.2 10.4 12.2 16 22 30 38 54 71 94 116 146 183 215 248 10.8 13.6 15.8 21 28 38 48 67 89 119 147 184 234 275 338 8.6 10.9 12.6 17 23 31 39 54 72 96 118 148 188 220 271 7.6 9.5 11.1 15 20 27 34 47 63 84 103 129 164 193 237 7.0 8.8 10.3 14 19 25 32 44 58 78 96 120 153 179 220 6.5 8.2 9.5 13 17 23 29 41 54 72 89 111 141 165 203 6.2 7.8 9.0 12 16 22 28 39 51 68 84 105 134 157 193 5.8 7.3 8.5 12 16 21 26 37 49 65 80 100 127 149 183 5.6 7.1 8.2 11 15 20 25 35 47 62 77 96 122 143 176 5.4 6.8 7.9 11 14 19 24 34 45 60 74 92 117 138 169 5.2 6.5 7.6 11 14 19 24 33 43 58 71 89 113 132 163 4.9 6.1 7.1 10 13 18 22 31 41 54 67 83 106 124 153 4.6 5.8 6.8 10 13 17 21 29 39 52 64 80 101 119 146 4.4 5.6 6.5 9 12 16 20 28 37 49 61 76 96 113 139 4.1 5.2 6.0 8 11 15 19 26 34 46 56 70 89 105 129 HUBER+SUHNER 165 Technical information</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=166</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=166</link><title>HUBER+SUHNER   Low Frequency Page 166</title><description>166 HUBER+SUHNER</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=167</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=167</link><title>HUBER+SUHNER   Low Frequency Page 167</title><description>Further catalogues RADOX® SOLAR Item no. 84017606 RADOX® wires and cables for the coil winding industry Item no. 84022718</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item><item><guid isPermaLink="true">http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=168</guid><link>http://ipaper.ipapercms.dk/hubersuhner/Technologies/Lowfrequency/WiresCablesEN/?Page=168</link><title>HUBER+SUHNER   Low Frequency Page 168</title><description>WAIVER It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they are intended for general informational purposes only. hubersuhner.com 84047253/12.2010 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS 16949 and IRIS. Huber+SuHner AG business unit Wire+Cable Degersheimerstrasse 14 9100 Herisau/Switzerland Tel. +41 71 353 4111 Fax +41 71 353 4647 info@hubersuhner.com</description><a10:updated>2012-08-14T13:42:14+02:00</a10:updated></item></channel></rss>