5.10 Rev. 2-11 Shaded area indicates change MUELLER® SINGLE SECTION SERVI-SEAL® PIPE REPAIR CLAMPS 501-509 Series Single Section Servi-Seal Pipe Repair Clamps — for 2" through 12" cast iron, ductile iron , steel, A-C and PVC pipe. Standard Lengths: 6", 7-1/2", 9", 10", 12", 15", 18", 20", 24", 30" Nominal Pipe Size 2" 2-1/2" 3" 3" 3" 3-1/2" 4" 4" 4" 4" 6" 6" 6" 6" 6" 6" 6" 8" 8" 8" 8" 8" 8" 10" 10" 10" 10" 10" 10" 12" 12" 12" 12" 12" 12" 12" Clamp size - number 235 270 297 346 373 396 445 474 495 520 566 594 634 655 684 704 722 792 836 853 899 925 940 990 1040 1064 1104 1137 1175 1200 1220 1246 1260 1314 1356 1400 Clamp O.D. range* Inches Millimeters Min. Max Min. Max 2.35 2.63 59.7 66.8 2.70 2.98 68.6 75.7 2.97 3.25 75.5 82.5 3.46 3.72 87.9 94.4 3.73 4.00 94.8 101.6 3.96 4.25 100.6 107.9 4.45 4.87 113.1 123.6 4.74 5.14 120.4 130.5 4.95 5.35 125.8 135.8 5.20 5.60 132.1 142.2 5.66 5.91 143.7 150.1 5.94 6.34 150.9 161.0 6.34 6.74 163.3 171.2 6.55 6.97 164.4 177.0 6.84 7.24 173.8 183.8 7.04 7.44 178.9 188.9 7.22 7.62 183.4 193.5 7.92 8.32 201.1 211.3 8.36 8.76 212.3 222.2 8.53 8.93 216.7 226.8 8.99 9.39 228.4 238.5 9.25 9.65 235.0 245.1 9.40 9.80 238.8 248.9 9.90 10.30 251.4 261.6 10.40 10.80 264.1 274.3 10.64 11.04 270.3 280.4 11.04 11.46 280.5 291.0 11.37 11.77 288.8 298.9 11.75 12.15 298.5 308.6 12.00 12.40 304.8 315.0 12.20 12.60 309.9 320.0 12.46 12.86 316.5 326.6 12.60 13.00 320.1 330.2 13.14 13.56 338.8 344.4 13.56 13.96 344.5 354.5 14.00 14.40 355.7 365.7 Cast Iron 50-250,A,B,C,D 50-250,A,B,C,D 50-250,A,B,C,D 50-250, A 50-250,A,B,C,D 50-250, A 50-250,A,B,C,D 50-250,A,B,C,D 50-250,A,B,C,D 50-250,A,B,C,D Ductile Iron All All All All All All All All All Cast Iron O.D. PVC Class 150, 200 Class 150, 200 Class 150, 200 Class 150, 200 Class 150, 200 Class 150, 200 Class 150, 200 Steel*** 2" 2-1/2" 3" O.D. 3" 3-1/2" (4" O.D.) STD 6" O.D. STD STD 8" O.D. STD 10" O.D. STD 12" O.D. STD 14" A-C Rough Barrel Class100**,150 Class100**.150 Class 150, 200 Class100**,150 Class 200 Class100**,150 Class 200 Class100** Class 100, 150 Class100** Class 150, 200 *Verify pipe O.D. before selecting clamp size. **CAUTION—O.D. of class 100 A-C pipe varies greatly. Measure pipe O.D. to assure proper clamp selection. ***Also fits PVC Plastic Pipe - ASTM D2241 SDR 17 and lower and ASTM D1785 schedule 80 and above. Note: For O.D. not shown contact our Customer Service Center or your Mueller Sales Representative. WARNING: Use on A-C pipe, which contains a known carcinogen, requires appropriate protective equipment and procedures be employed.
MUELLER® XTRA-RANGE® FULL-SEAL® PIPE REPAIR CLAMPS Typical XTRA-RANGE Full-Seal Clamp Shaded area indicates change Rev. 9-09 5.11 Mueller 510 Series Xtra-Range Full-Seal Pipe Repair Clamps - for 4" through 24" cast iron, ductile iron, steel pipe, A-C and PVC pipe. 510 Series Xtra-Range Full-Seal Pipe Repair Clamps - for 4" through 24" cast iron, ductile iron, steel pipe, A-C and PVC pipe. To specify the catalog number, provide the following information : 1.Stylenumber—510 2.Length—Standard length available (inches): 6, 7-1/2 (list as “7”), 9, 12, 15, 18, 20, 24, 30 3.Sizenumber—from chart on page 15.12 4.Catalognumberprefixorsufixforoptionalfeatures,ifdesired. The catalog number for a 510 Xtra-Range Full-Seal Repair Clamp, 12" long for 6" cast iron pipe is 510-12-675. Style number 510 Clamp style number 510 Clamp length 12 Clamp size number 675 Extra bolts and nuts for Mueller Xtra-Range Full Seal Repair Clamps Starter nut Clamp size 4"-12" (standard bolt and nut) 4"-12" (starter bolt and nut) Bolt size 5/8"x6" 5/8x7" Bolt part number 521008 524308 Nut part number 195236 526655 NOTE: 4" and larger 510 Series Clamps are provided with one starter bolt/nut per side as standard. Standard bolt & nut 510 Series nuts and bolts Stainless steel bolts Foroptional304stainlesssteelbolts,washersandnuts,add“S-”prefixtoclampcatalognumber. Example: S-510-12-675. Deep socket wrenchs SpeciallydesignedforusewithMuellerFull-SealRepairClamps.Long ratchet handle has thumb-tip reverse. Deep sockets (3-1/4") have double hex (12 pt.) and 1/2" square drive. Bonding device Part number 515207 515204 519575 Description 1-1/16" socket 15-3/4" with reversible ratchet handle 1/2"x3/4" adapter Bonding device for cathodic protection Metallicconductorsaresetinthegaskettoprovidecontactbetweenthebandandthepipesurface andareavailableonall500seriesclamps.Theseconductorspermitelectricalcurrentflowby establishing positive contact with pipe and band on each side of the pipe crack or break. To specify optional bonding deviceforcathodicprotection,addaprefixof“2”tocatalognumber. Example: 2-510-12-675. Bonding device Add-on feature allows long lengthwise repairs The gasket is cemented into the band in a 1" offset position. This allows overlapping the gasket with the band of another offset clamp when repairing a longer than usual area of pipe. This feature is not available on Servi-Seal style clamps. PIPE GASKET BAND To specify optional add-on featureforlongerthanusualrepairs,addaprefixof“1”tocatalognumber. Example: 1-510-12-675. Add-on feature IMPORTANT: PIPE REPAIR CLAMPS have demonstrated their capability to seal against water pressures commonly encountered in distribution systems. Smaller diameter clamps of a given design can seal against higher pressures than larger ones. In addition, the pressure that a clamp can contain is effected by the torque applied to the bolts, the uniformity of bolt tightening (when there is more than one bolt), as well as the type and extent of pipe damage, surface condition of the pipe, enviromental conditions, and installation workmanship. Note: For O.D. not shown contact our Customer Service Center or your Mueller Sales Representative. WARNING: Use on A-C pipe, which contains a known carcinogen, requires appropriate protective equipment and procedures be employed.