Page number 28

9.28 Rev. 12-06 Shaded area indicates changes MUELLER ® NO-BLO ® BOTTOM OUT LINE STOPPER FITTING WELDING TYPE - 250 PSIG o Catalog number – H-17160 o Sizes – 1-1/2", 2", 2-1/2" o For use on steel pipe only o Bottom out feature o Fitting top and bottom halves are forged steel (ASTM A105) o Completion Plug makes primary seal o Cast Iron Completion Cap makes secondary seal o 250 psig* (1724kPa) H-17160 How to select equipment 1) Find chart on following pages containing desired combination of fitting and installation machine (shown in bold type at top of each page and chart). Note: for a given fitting there may be more than one machine and chart. 2) Under inlet size of fitting to be installed, select catalog number for type of control valve to be used. Options may include one or more of the following: H-10914 Bronze Gate Valve, H-17025 Control Chamber, H-10917 Slide Gate Valve, H-10918 Steel Ball Valve. 3) Under selected control valve, column lists equipment necessary for each operation on chosen size of fitting. Note: MAOP (Maximum Allowed Operating Pressure) provided for each operation must not be exceeded. MAOP may be different for each operation. Pipe Dimensions Size of Line Stopper Fitting 1-1/2" 2" 2-1/2" Outside Diameter of Shell Cutter Required (Inches) 2.250 2.250 2.625 Outside Diameter of Pipe (Inches) 1.900 2.375 2.875 Replacement Parts Replacement Parts Completion Cap Completion Plug 1-1/2" 36311 36303 Size of Fitting 2" 36311 36303 2-1/2" 36312 36402 * This is the maximum pressure of the fitting installed in the line at 100F for Class Locations 1, 2, 3 and 4 as defined in D.O.T./CFR TITLE 49 PART 192. It may be necessary to reduce the line pressure during the drilling, stopping or plugging operations to the maximum working pressure of the machine or its attachments. Refer to charts on following pages.

Page number 29

MUELLER ® NO-BLO ® LINE STOPPER FITTING H-17160 9.29 Shaded area indicates change Rev. 9-17 D-5 ™ /DH-5 ™ and Unit #1 Machine H-17160 Control Valve Bushing 1-1/2" H-10914 2-1/2" - 1-1/2" H-10917 2-1/2" 507782 2" H-10914 2-1/2" - Installation Test Cap Completion Plug Wrench 36812 581264 36812 581264 36812 581264 Drilling MAOP* Power Operator Machine Adapter Cutter Arbor 125 psig H-604 36289 88470 250 psig H-604 36289 88470 125 psig H-604 36289 88470 Shell Cutter 36337 2-1/4" 36337 2-1/4" 36337 2-1/4" Pilot Drill Cutting Grease Honing Stone Stopping MAOP* Stopping Machine Stopping Machine Adapter Solid Rubber Stopper Replacement Rubber Top Bypass Rubber Stopper Replacement Rubber Bottom Bypass Rubber Stopper Replacement Rubber Full Bypass Rubber Stopper Replacement Rubber Bottom-Out Stopper Replacement Seal Rubber Stopper Lubricant Inserting MAOP* Inserting Machine Inserting Machine Adapter Inserting Tool Extracting MAOP* Extracting Machine Extracting Machine Adapter Extracting Tool 36336 88366 682560 125 psig H-17135 36281 88478 36290 88471 36298 81495 36298 680513 509446 681989 529002 580657 125 psig H-17135 36281 580940 125 psig H-17135 36281 580941 36336 88366 682560 125 psig H-17135 36281 88478 36290 88471 36298 81495 36298 680513 509446 681989 529002 580657 125 psig H-17135 36281 580940 125 psig H-17135 36281 580941 36336 88366 682560 125 psig H-17135 36281 88478 36290 88471 36298 81495 36298 680513 509446 681989 529002 580657 125 psig H-17135 36281 580940 125 psig H-17135 36281 580941 2" H-10917 2-1/2" 507782 36812 581264 250 psig H-604 36289 88470 36337 2-1/4" 36336 88366 682560 125 psig H-17135 36281 88478 36290 88471 36298 81495 36298 680513 509446 681989 529002 580657 125 psig H-17135 36281 580940 125 psig H-17135 36281 580941 2-1/2" H-10914 3" - 36813 581264 125 psig H-604 36376 88601 36374 2-5/8" 36336 88366 682560 125 psig H-17135 36370 88482 36283 88485 36372 - - - - - - 580657 125 psig H-17135 36370 580940 125 psig H-17135 36370 580941 2-1/2" H-10917 3" 507783 36813 581264 250 psig H-604 36376 88601 36374 2-5/8" 36336 88366 682560 125 psig H-17135 36370 88482 36283 88485 36372 - - - - - - 580657 125 psig H-17135 36370 580940 125 psig H-17135 36370 580941 *Maximum Allowable Operating Pressure

    ...