The natural respiration of fruit and vegetables increases CO2 while reducing O2 if left in a closed environment. The AV+ valves open and close to keep CO2 levels below or the O2 levels above their corresponding set points. CO2 and/or O2 set points can be entered via the simple user panel, in the same way that the temperature set point is selected. AV+ ensures that a safe atmosphere is maintained while minimising the amount of fresh air. Feature The fresh air valves are activated via the sensor and controller. If required, you can also switch to normal fresh air intake by turning the butterfly wing Perishables will increase the CO2 level until the control point is reached, at which point fresh air will be allowed to enter the container Balancing the CO2/O2 levels OPTION